{"id":15102,"date":"2026-11-21T10:00:00","date_gmt":"2026-11-21T07:00:00","guid":{"rendered":"https:\/\/www.ulpatek.com\/?p=15102"},"modified":"2026-10-02T08:01:03","modified_gmt":"2026-10-02T05:01:03","slug":"hava-filtresinin-enerji-tuketimi-nasil-hesaplanir","status":"publish","type":"post","link":"https:\/\/www.ulpatek.com\/tr\/filtre-teknolojisi\/hava-filtresinin-enerji-tuketimi-nasil-hesaplanir\/","title":{"rendered":"Hava filtresinin enerji t\u00fcketimi nas\u0131l hesaplan\u0131r? Form\u00fcl, varsay\u0131mlar ve \u00fccretsiz hesap tablosu"},"content":{"rendered":"<p>Sabit hava debisinde filtrenin bas\u0131n\u00e7 kayb\u0131n\u0131 kar\u015f\u0131lamak i\u00e7in t\u00fcketilen elektri\u011fi tahmin etmek i\u00e7in hava debisini ortalama filtre bas\u0131n\u00e7 kayb\u0131 ve \u00e7al\u0131\u015fma saatleriyle \u00e7arp\u0131n; ard\u0131ndan toplam verime ve 1.000\u2019e b\u00f6l\u00fcn. Hava debisi m\u00b3\/s, bas\u0131n\u00e7 Pa, s\u00fcre saat oldu\u011funda sonu\u00e7 kWh cinsindedir.<\/p>\n<p>\u00d6nemli girdi, <strong>\u00e7al\u0131\u015fma s\u0131ras\u0131ndaki ortalama bas\u0131n\u00e7 kayb\u0131d\u0131r<\/strong>. Temiz filtrenin bas\u0131n\u00e7 kayb\u0131, kullan\u0131m d\u00f6neminin yaln\u0131zca ba\u015flang\u0131c\u0131ndaki de\u011ferdir; b\u00fct\u00fcn y\u0131l\u0131 temsil etmez.<\/p>\n<p><strong><a href=\"https:\/\/www.ulpatek.com\/wp-content\/uploads\/ulpatek-guides\/downloads\/E2-air-filter-energy-calculator-tr.xlsx\">D\u00fczenlenebilir hava filtresi enerji hesaplay\u0131c\u0131s\u0131n\u0131 indirin<\/a>.<\/strong> \u0130ki filtre s\u00fctunu, g\u00f6r\u00fcn\u00fcr hesap ad\u0131mlar\u0131 ve y\u0131ll\u0131k maliyet kar\u015f\u0131la\u015ft\u0131rmas\u0131 i\u00e7erir. Ba\u015flang\u0131\u00e7 rakamlar\u0131 \u00f6rnektir; g\u00fcncel teklifler veya \u00f6l\u00e7\u00fclm\u00fc\u015f saha tasarruflar\u0131 de\u011fildir.<\/p>\n<h2>Birimleriyle birlikte form\u00fcl<\/h2>\n<p><strong>E = q \u00d7 \u0394p\u0304 \u00d7 t \u00f7 (1.000 \u00d7 \u03b7)<\/strong><\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>Simge<\/th>\n<th>Girilecek de\u011fer<\/th>\n<th>Birim<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>E<\/td>\n<td>Filtre direnciyle ili\u015fkili hesaplanm\u0131\u015f elektrik<\/td>\n<td>kWh<\/td>\n<\/tr>\n<tr>\n<td>q<\/td>\n<td>Filtreden veya se\u00e7ilen filtre grubundan ge\u00e7en hava debisi<\/td>\n<td>m\u00b3\/s<\/td>\n<\/tr>\n<tr>\n<td>\u0394p\u0304<\/td>\n<td>Zaman ortalamal\u0131 filtre bas\u0131n\u00e7 kayb\u0131<\/td>\n<td>Pa<\/td>\n<\/tr>\n<tr>\n<td>t<\/td>\n<td>\u00c7al\u0131\u015fma s\u00fcresi<\/td>\n<td>saat<\/td>\n<\/tr>\n<tr>\n<td>\u03b7<\/td>\n<td>Elektrik giri\u015finden yararl\u0131 hava g\u00fcc\u00fcne kadar toplam verim<\/td>\n<td>Ondal\u0131k, \u00f6rne\u011fin 0,70<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Form\u00fcl, belirtilen \u00e7al\u0131\u015fma ko\u015fullar\u0131 i\u00e7in m\u00fchendislik tahminidir. Eurovent 4\/24, \u00e7al\u0131\u015fma ko\u015fullar\u0131nda filtre enerjisi de\u011ferlendirmesini a\u00e7\u0131klar ve bu ko\u015fullar\u0131n neden \u00f6nemli oldu\u011funu anlat\u0131r. Standartla\u015ft\u0131r\u0131lm\u0131\u015f enerji etiketi ise farkl\u0131 bir ama\u00e7la, \u00fcr\u00fcnleri tan\u0131ml\u0131 ortak ko\u015fullarda kar\u015f\u0131la\u015ft\u0131rmak i\u00e7in kullan\u0131l\u0131r. <a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/publications-files\/eurovent-rec-4-24-energy-consumption-evaluation-2023-en-update-1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/24\u20132023, Update 1<\/a>.<\/p>\n<p>Bas\u0131n\u00e7 ile hacimsel debinin \u00e7arp\u0131m\u0131, watt cinsinden hava g\u00fcc\u00fcn\u00fc verir. Toplam verime b\u00f6lmek, bu modelde kar\u015f\u0131l\u0131k gelen elektrik giri\u015f g\u00fcc\u00fcn\u00fc verir. Saatle \u00e7arpmak Wh, 1.000\u2019e b\u00f6lmek kWh verir.<\/p>\n<h2>Ad\u0131m 1: Hava debisini d\u00f6n\u00fc\u015ft\u00fcr\u00fcn<\/h2>\n<p>Bir\u00e7ok filtre teknik f\u00f6y\u00fc hava debisini m\u00b3\/h cinsinden verir. Form\u00fcl\u00fc kullanmadan \u00f6nce bu say\u0131y\u0131 3.600\u2019e b\u00f6l\u00fcn:<\/p>\n<p><strong>3.400 m\u00b3\/h \u00f7 3.600 = 0,944444 m\u00b3\/s.<\/strong><\/p>\n<p>Saatleri de 3.600\u2019e b\u00f6lmeyin. Sonu\u00e7 kWh cinsinden enerji oldu\u011fu i\u00e7in form\u00fcl \u00e7al\u0131\u015fma s\u00fcresini zaten saat olarak kullan\u0131r.<\/p>\n<p>Paralel filtre grubunda hesab\u0131n tek filtreyi mi yoksa t\u00fcm grubu mu kapsad\u0131\u011f\u0131na karar verin. On e\u015fit filtre debiyi payla\u015f\u0131yorsa tek filtre hesab\u0131nda o filtrenin debisi kullan\u0131l\u0131r. Grup hesab\u0131nda grubun toplam debisi ve grup \u00fczerindeki bas\u0131n\u00e7 kayb\u0131 kullan\u0131l\u0131r. Toplam grup debisini kullan\u0131p sonucu yeniden onla \u00e7arpmay\u0131n.<\/p>\n<p>Seri filtre kademeleri farkl\u0131d\u0131r. Ayn\u0131 hava her kademeden ge\u00e7er ve bas\u0131n\u00e7 kay\u0131plar\u0131 toplam hava yoluna eklenir. \u0130lgili kademeleri iki kez saymadan \u00f6l\u00e7\u00fcn veya modelleyin.<\/p>\n<h2>Ad\u0131m 2: Hesab\u0131n ko\u015fullar\u0131na uygun ortalama bas\u0131n\u00e7 kayb\u0131n\u0131 belirleyin<\/h2>\n<p>Hesap tablosu, her filtre \u00e7evriminde direncin \u00e7al\u0131\u015fma s\u00fcresiyle do\u011frusal artt\u0131\u011f\u0131n\u0131 varsayar. Bu varsay\u0131m alt\u0131nda:<\/p>\n<p><strong>Ortalama bas\u0131n\u00e7 kayb\u0131 = (ba\u015flang\u0131\u00e7 bas\u0131n\u00e7 kayb\u0131 + son bas\u0131n\u00e7 kayb\u0131) \u00f7 2.<\/strong><\/p>\n<p>Ba\u015flang\u0131\u00e7ta 100 Pa ve sonda 200 Pa i\u00e7in ortalama 150 Pa\u2019d\u0131r. Aradaki 100 Pa fark, diren\u00e7 art\u0131\u015f\u0131d\u0131r. Ortalama de\u011fildir.<\/p>\n<p>\u0130ki u\u00e7 de\u011ferin ortalamas\u0131n\u0131, yaln\u0131zca do\u011frusal art\u0131\u015f varsay\u0131m\u0131 yapman\u0131z hesap amac\u0131na uygunsa kullan\u0131n. Ger\u00e7ek y\u00fcklenme h\u0131zlanabilir veya toz olay\u0131ndan sonra de\u011fi\u015febilir. \u00d6l\u00e7\u00fclm\u00fc\u015f kay\u0131tlar varsa hesab\u0131 iyile\u015ftirmek i\u00e7in bunlar\u0131 kullan\u0131n.<\/p>\n<p>Test tozu gram\u0131na g\u00f6re \u00e7izilmi\u015f laboratuvar e\u011frisi, kendili\u011finden \u00e7al\u0131\u015fma saatlerine g\u00f6re e\u011fri olmaz. ISO 16890-3:2024, belirtilmi\u015f toz tutulduk\u00e7a direnci \u00f6l\u00e7er; bu e\u011friyi i\u015fletmedeki \u00e7al\u0131\u015fma s\u00fcresiyle ili\u015fkilendirmek i\u00e7in ger\u00e7ek toz y\u00fcklenmesine dayanan bir model gerekir. <a href=\"https:\/\/www.iso.org\/standard\/83047.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 16890-3:2024<\/a>.<\/p>\n<h2>Ad\u0131m 3: Do\u011fru verimi girin<\/h2>\n<p>Bu form\u00fcldeki \u03b7, <strong>H13 verimi, H14 verimi veya ePM1 verimi de\u011fildir<\/strong>. Elektrik giri\u015finin yararl\u0131 hava g\u00fcc\u00fcne d\u00f6n\u00fc\u015f\u00fcm\u00fcn\u00fc tan\u0131mlar.<\/p>\n<p>Fan, motor ve varsa s\u00fcr\u00fcc\u00fc kay\u0131plar\u0131 i\u00e7in tutarl\u0131 hesap s\u0131n\u0131r\u0131 gerekir. Motor veriminin %90 olmas\u0131, fan sisteminin tamam\u0131n\u0131n elektrik giri\u015finin %90\u2019\u0131n\u0131 yararl\u0131 hava g\u00fcc\u00fcne \u00e7evirdi\u011fi anlam\u0131na gelmez. \u00c7al\u0131\u015fma noktas\u0131 verilerini veya a\u00e7\u0131k\u00e7a belirtilmi\u015f varsay\u0131m\u0131 kullan\u0131n.<\/p>\n<p>Adaylar\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131rken ayn\u0131 hesap s\u0131n\u0131r\u0131n\u0131 koruyun. Hesaplardan biri yaln\u0131zca fan verimini, di\u011feri elektrik giri\u015finden hava g\u00fcc\u00fcne kadar toplam verimi kullan\u0131yorsa sonu\u00e7lar\u0131 do\u011frudan kar\u015f\u0131la\u015ft\u0131r\u0131lamaz. DOE fan sistemi rehberi, sistem g\u00fcc\u00fc ve \u00e7al\u0131\u015fma noktas\u0131 de\u011ferlendirmesi i\u00e7in yararl\u0131 referanst\u0131r. <a href=\"https:\/\/www.energy.gov\/sites\/prod\/files\/2014\/05\/f16\/fan_sourcebook.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">DOE: Fan Sistemi Performans\u0131n\u0131 \u0130yile\u015ftirme<\/a>.<\/p>\n<h2>Ad\u0131m 4: \u00d6nce enerjiyi, sonra maliyeti hesaplay\u0131n<\/h2>\n<p>Hesap tablosundaki Filtre A \u00f6rne\u011fi kullan\u0131ld\u0131\u011f\u0131nda:<\/p>\n<p><strong>E = 0,944444 \u00d7 150 \u00d7 6.000 \u00f7 (1.000 \u00d7 0,70) = 1.214,29 kWh\/y\u0131l.<\/strong><\/p>\n<p>Varsay\u0131lan \u20ac0,283\/kWh ile:<\/p>\n<p><strong>Elektrik maliyeti = 1.214,285714 \u00d7 0,283 = \u20ac343,64\/y\u0131l.<\/strong><\/p>\n<p>Hesapta yuvarlanmam\u0131\u015f de\u011ferleri koruyun; g\u00f6sterilen sonucu yuvarlay\u0131n. Dahil edilen filtre al\u0131m ve de\u011fi\u015fim maliyetlerini ayr\u0131 ekleyin.<\/p>\n<p>\u00c7al\u0131\u015fma kitab\u0131, Ulpatek\u2019in Temmuz 2024 katalo\u011funun 68. sayfas\u0131ndaki ge\u00e7mi\u015f girdilerle a\u00e7\u0131l\u0131r. Enerji rakamlar\u0131 a\u00e7\u0131k do\u011frusal art\u0131\u015f varsay\u0131m\u0131yla yeniden hesaplanm\u0131\u015ft\u0131r. Kaynaktaki adaylar\u0131n ePM1 de\u011ferleri farkl\u0131d\u0131r: %85 ve %80. Maliyet belirleyici olmadan \u00f6nce ikisi de proje gereklili\u011fini kar\u015f\u0131lamal\u0131d\u0131r. <a href=\"https:\/\/www.ulpatek.com\/wp-content\/uploads\/2024\/07\/Product-Technical-Catalogue-24_07_24.pdf#page=68\" target=\"_blank\" rel=\"noopener noreferrer\">Ulpatek katalo\u011fu, sayfa 68<\/a>. <a href=\"https:\/\/www.ulpatek.com\/tr\/filtre-teknolojisi\/hava-filtresinin-gercek-maliyeti\/\" data-ulpatek-guide=\"E1\">A\u00e7\u0131klamal\u0131 TCO makalesi<\/a> bu kar\u015f\u0131la\u015ft\u0131rmay\u0131 b\u00fct\u00fcn\u00fcyle a\u00e7\u0131klar.<\/p>\n<h2>Hesap tablosunda neleri de\u011fi\u015ftirebilirsiniz?<\/h2>\n<p>Hava debisi, saat, toplam verim, tarife, ba\u015flang\u0131\u00e7 ve \u00e7evrim sonu bas\u0131nc\u0131, y\u0131ll\u0131k al\u0131m\/de\u011fi\u015fim say\u0131s\u0131, filtre fiyat\u0131 ve de\u011fi\u015fim ba\u015f\u0131na di\u011fer maliyet i\u00e7in kehribar renkli giri\u015f h\u00fccrelerini d\u00fczenleyin.<\/p>\n<p>Planlanan de\u011fi\u015fim say\u0131s\u0131n\u0131 kendiniz girin. \u00c7al\u0131\u015fma kitab\u0131 bas\u0131n\u00e7 kayb\u0131ndan kullan\u0131m \u00f6mr\u00fc tahmin etmez veya de\u011fi\u015fim takvimi \u00e7\u0131karmaz. Belirtilen ortalama bas\u0131nc\u0131n de\u011ferlendirilen \u00e7al\u0131\u015fma saatlerini temsil etti\u011fini varsayar.<\/p>\n<p>Sonu\u00e7lar filtreyle ili\u015fkili elektri\u011fi, elektrik maliyetini, filtre\/de\u011fi\u015fim maliyetini ve bunlar\u0131n toplam\u0131n\u0131 g\u00f6sterir. Pozitif tasarruf, dahil edilen kapsam i\u00e7inde Filtre A\u2019n\u0131n daha d\u00fc\u015f\u00fck maliyetli oldu\u011fu anlam\u0131na gelir.<\/p>\n<p>Zorunlu bir giri\u015f eksik veya ge\u00e7ersizse ilgili sonu\u00e7 h\u00fccresinde \u201cn.a.\u201d g\u00f6r\u00fcn\u00fcr. \u00d6rne\u011fin s\u0131f\u0131r toplam verim ge\u00e7erli enerji sonucu \u00fcretemez. \u00c7al\u0131\u015fma saati s\u0131f\u0131r oldu\u011funda hesaplanan enerji t\u00fcketimi de s\u0131f\u0131r olabilir; ancak ayr\u0131ca girilmi\u015f filtre al\u0131m maliyeti toplamda yer almaya devam edebilir.<\/p>\n<p>Tek para birimini tutarl\u0131 kullan\u0131n. \u00c7al\u0131\u015fma kitab\u0131nda \u00f6rnek EUR olarak etiketlenmi\u015ftir; kar\u015f\u0131la\u015ft\u0131rman\u0131z ba\u015fka para birimi kullan\u0131yorsa rakamlarla birlikte etiketleri de de\u011fi\u015ftirin.<\/p>\n<h2>Zaman aral\u0131kl\u0131 hesap ne zaman gerekir?<\/h2>\n<p>Hava debisi, diren\u00e7 veya verim \u00f6nemli \u00f6l\u00e7\u00fcde de\u011fi\u015fiyorsa i\u015fletme kayd\u0131n\u0131 aral\u0131klara b\u00f6l\u00fcn. Her aral\u0131\u011f\u0131n enerjisini hesaplay\u0131n ve sonu\u00e7lar\u0131 toplay\u0131n.<\/p>\n<p>\u00d6rne\u011fin \u015fu <strong>temsili \u00f6rnek ko\u015fullar\u0131<\/strong> varsayal\u0131m:<\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>Aral\u0131k<\/th>\n<th align=\"right\">Hava debisi<\/th>\n<th align=\"right\">Filtre bas\u0131n\u00e7 kayb\u0131<\/th>\n<th align=\"right\">Saat<\/th>\n<th align=\"right\">Toplam verim<\/th>\n<th align=\"right\">Enerji<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1<\/td>\n<td align=\"right\">1,0 m\u00b3\/s<\/td>\n<td align=\"right\">100 Pa<\/td>\n<td align=\"right\">1.000<\/td>\n<td align=\"right\">0,60<\/td>\n<td align=\"right\">166,67 kWh<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td align=\"right\">0,5 m\u00b3\/s<\/td>\n<td align=\"right\">80 Pa<\/td>\n<td align=\"right\">1.000<\/td>\n<td align=\"right\">0,60<\/td>\n<td align=\"right\">66,67 kWh<\/td>\n<\/tr>\n<tr>\n<td><strong>Toplam<\/strong><\/td>\n<td align=\"right\"><\/td>\n<td align=\"right\"><\/td>\n<td align=\"right\"><strong>2.000<\/strong><\/td>\n<td align=\"right\"><\/td>\n<td align=\"right\"><strong>233,33 kWh<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Ayr\u0131 ortalama debi 0,75 m\u00b3\/s ile ayr\u0131 ortalama bas\u0131n\u00e7 90 Pa kullan\u0131larak yap\u0131lan \u00e7arp\u0131m 225 kWh verir. Sonu\u00e7 farkl\u0131d\u0131r; \u00e7\u00fcnk\u00fc debi ve bas\u0131n\u00e7 birlikte de\u011fi\u015fmi\u015ftir. \u00c7al\u0131\u015fma ko\u015fullar\u0131 de\u011fi\u015fkense daha k\u0131sa aral\u0131klar veya uygun zaman serisi verileri daha iyi tahmin verir.<\/p>\n<p>Sunulan \u00e7al\u0131\u015fma kitab\u0131 bilin\u00e7li olarak basit, sabit \u00e7al\u0131\u015fma ko\u015fullu kar\u015f\u0131la\u015ft\u0131rmad\u0131r. Bu daha ayr\u0131nt\u0131l\u0131 y\u00f6ntemi gerektiren de\u011fi\u015fken i\u015fletme ge\u00e7mi\u015fini temsil etmeye zorlamay\u0131n.<\/p>\n<h2>Sonu\u00e7 neleri i\u00e7ermez?<\/h2>\n<p>Hesap, se\u00e7ilen filtre direnciyle ili\u015fkili elektrik katk\u0131s\u0131n\u0131 kapsar. Is\u0131tmay\u0131, so\u011futmay\u0131, klima santralindeki di\u011fer t\u00fcm bas\u0131n\u00e7 kay\u0131plar\u0131n\u0131 veya binan\u0131n b\u00fct\u00fcn enerji kullan\u0131m\u0131n\u0131 i\u00e7ermez.<\/p>\n<p>Sabit h\u0131zl\u0131 fan\u0131n farkl\u0131 filtreye nas\u0131l tepki verece\u011fini de tahmin etmez. Daha d\u00fc\u015f\u00fck diren\u00e7, beklenen elektrik giri\u015f azalmas\u0131n\u0131 olu\u015fturmak yerine hava debisini art\u0131rabilir. Saha tasarrufu sunmadan \u00f6nce kontrolleri ve fan e\u011frisini kontrol edin.<\/p>\n<h2>Kaynaklar<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/publications-files\/eurovent-rec-4-24-energy-consumption-evaluation-2023-en-update-1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/24\u20132023, Update 1<\/a><\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/83047.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 16890-3:2024<\/a><\/li>\n<li><a href=\"https:\/\/www.energy.gov\/sites\/prod\/files\/2014\/05\/f16\/fan_sourcebook.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">DOE: Fan Sistemi Performans\u0131n\u0131 \u0130yile\u015ftirme<\/a><\/li>\n<li><a href=\"https:\/\/www.ulpatek.com\/wp-content\/uploads\/2024\/07\/Product-Technical-Catalogue-24_07_24.pdf#page=68\" target=\"_blank\" rel=\"noopener noreferrer\">Ulpatek katalo\u011fu, sayfa 68<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Filtre kaynakl\u0131 enerjiyi ve maliyeti \u00fccretsiz hesap tablosuyla bulun. Debi birimini, ortalama bas\u0131n\u00e7 kayb\u0131n\u0131, verimi ve de\u011fi\u015fen ko\u015fullar\u0131 kontrol edin.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[457],"tags":[],"class_list":["post-15102","post","type-post","status-publish","format-standard","hentry","category-guide-energy-tr"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15102","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/comments?post=15102"}],"version-history":[{"count":2,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15102\/revisions"}],"predecessor-version":[{"id":17789,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15102\/revisions\/17789"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/media?parent=15102"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/categories?post=15102"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/tags?post=15102"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}