{"id":15095,"date":"2026-10-31T10:00:00","date_gmt":"2026-10-31T07:00:00","guid":{"rendered":"https:\/\/www.ulpatek.com\/?p=15095"},"modified":"2026-10-01T14:05:50","modified_gmt":"2026-10-01T11:05:50","slug":"eurovent-a-plus-e-enerji-siniflari","status":"publish","type":"post","link":"https:\/\/www.ulpatek.com\/tr\/filtre-teknolojisi\/eurovent-a-plus-e-enerji-siniflari\/","title":{"rendered":"Eurovent A+\u2013E enerji s\u0131n\u0131flar\u0131: Fiyat kar\u015f\u0131la\u015ft\u0131r\u0131rken filtreniz i\u00e7in ge\u00e7erli kWh s\u0131n\u0131r\u0131n\u0131 kontrol edin"},"content":{"rendered":"<p>A+ s\u0131n\u0131f\u0131ndaki t\u00fcm filtrelere uygulanan tek bir y\u0131ll\u0131k enerji s\u0131n\u0131r\u0131 yoktur. Eurovent s\u0131n\u0131r\u0131, partik\u00fcl verim grubuna ve beyan edilen verim aral\u0131\u011f\u0131na ba\u011fl\u0131d\u0131r. ePM1 %50 filtre ile ePM1 %80 filtre, farkl\u0131 beyan edilmi\u015f enerji de\u011ferlerine sahipken ikisi de A+ olabilir.<\/p>\n<p>Enerji s\u0131n\u0131f\u0131, filtrasyon performans\u0131n\u0131n yan\u0131nda filtre direncinden kaynaklanan enerji t\u00fcketimini de kar\u015f\u0131la\u015ft\u0131rmay\u0131 sa\u011flar. Al\u0131c\u0131lar yaln\u0131zca harfi kar\u015f\u0131la\u015ft\u0131rd\u0131\u011f\u0131nda, filtrasyon gereklili\u011fini g\u00f6z ard\u0131 etti\u011finde veya enerji s\u0131n\u0131f\u0131n\u0131 kendi binalar\u0131nda \u00f6l\u00e7\u00fclecek elektrik t\u00fcketiminin tahmini sayd\u0131\u011f\u0131nda yan\u0131lt\u0131c\u0131 h\u00e2le gelir.<\/p>\n<p>G\u00fcncel Hava Filtreleri Teknik Belgelendirme Kurallar\u0131 ECP 11 FIL 2026, burada kullan\u0131lan s\u0131n\u0131f tablolar\u0131n\u0131 i\u00e7erir. Enerji hesab\u0131n\u0131n referans\u0131 Eurovent 4\/21-2019 olmaya devam eder. <a href=\"https:\/\/www.eurovent-certification.com\/media\/images\/TCR\/_EC\/TCR_ECP_FIL_2026_6a1954ee8ba76.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 2026 belgelendirme kurallar\u0131<\/a>, <a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/publications-files\/eurovent-rec-4-21-energy-efficiency-evaluation-of-air-filters-for-general-ventilation-purposes-fourth-edition-2019-en.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/21-2019<\/a><\/p>\n<h2>Enerji de\u011feri neyi temsil eder?<\/h2>\n<p>Filtre hava ak\u0131\u015f\u0131na diren\u00e7 olu\u015fturur. Gerekli havay\u0131 bu diren\u00e7ten ge\u00e7irmek fan g\u00fcc\u00fc gerektirir. Yararl\u0131 bir enerji kar\u015f\u0131la\u015ft\u0131rmas\u0131 i\u00e7in diren\u00e7, yaln\u0131zca filtre yeniyken de\u011fil, y\u00fcklenme boyunca de\u011ferlendirilmelidir.<\/p>\n<p>Eurovent 4\/21, ortalama bas\u0131n\u00e7 kayb\u0131n\u0131 elde etmek i\u00e7in tan\u0131ml\u0131 bir laboratuvar toz y\u00fckleme prosed\u00fcr\u00fc kullan\u0131r. Referans hesab\u0131nda 0,944 m\u00b3\/s hava debisi, y\u0131lda 6.000 \u00e7al\u0131\u015fma saati ve 0,50 fan verimi kullan\u0131l\u0131r. Bu sabit varsay\u0131mlar \u00fcr\u00fcnlerin ortak esasta kar\u015f\u0131la\u015ft\u0131r\u0131lmas\u0131n\u0131 sa\u011flar. <a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/publications-files\/eurovent-rec-4-21-energy-efficiency-evaluation-of-air-filters-for-general-ventilation-purposes-fourth-edition-2019-en.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/21, b\u00f6l\u00fcmler 2\u20133<\/a><\/p>\n<p>Filtrenin belirtilen kWh\u2019yi kendi ba\u015f\u0131na t\u00fcketen elektrik motoru yoktur. Say\u0131, derecelendirme ko\u015fullar\u0131nda filtrenin direnciyle ili\u015fkili hesaplanm\u0131\u015f fan elektri\u011fini temsil eder. Binan\u0131n b\u00fct\u00fcn \u0131s\u0131tma, so\u011futma veya havaland\u0131rma enerjisini i\u00e7ermez.<\/p>\n<p>Ortalama alma y\u00f6ntemi de \u00f6nemlidir. Son bas\u0131n\u00e7 kayb\u0131ndan temiz filtre bas\u0131n\u00e7 kayb\u0131n\u0131 \u00e7\u0131karmak diren\u00e7 art\u0131\u015f\u0131n\u0131 verir; fan\u0131n kullan\u0131m s\u00fcresi boyunca kar\u015f\u0131lamak zorunda oldu\u011fu ortalama direnci vermez. Yaln\u0131zca temiz durumu kar\u015f\u0131la\u015ft\u0131rmak, filtreler y\u00fcklendik\u00e7e olu\u015fan \u00f6nemli farklar\u0131 ka\u00e7\u0131rabilir.<\/p>\n<h2>ePM1 aral\u0131klar\u0131 ayr\u0131 tutulmal\u0131d\u0131r<\/h2>\n<p>A\u015fa\u011f\u0131daki se\u00e7ilmi\u015f sat\u0131rlar, 2026 kurallar\u0131ndaki ePM1 s\u0131n\u0131rlar\u0131n\u0131 aktar\u0131r. De\u011ferler referans hava debisinde kWh\/y\u0131l cinsinden y\u0131ll\u0131k enerji t\u00fcketimidir. A+ ile D aras\u0131ndaki de\u011ferler \u00fcst s\u0131n\u0131rlar\u0131 g\u00f6sterir; E, D s\u0131n\u0131r\u0131n\u0131n \u00fczerindedir. \u00dcr\u00fcne, s\u0131n\u0131r\u0131n\u0131 kar\u015f\u0131lad\u0131\u011f\u0131 en iyi s\u0131n\u0131f atan\u0131r.<\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>ISO ePM1 verim aral\u0131\u011f\u0131<\/th>\n<th align=\"right\">A+<\/th>\n<th align=\"right\">A<\/th>\n<th align=\"right\">B<\/th>\n<th align=\"right\">C<\/th>\n<th align=\"right\">D<\/th>\n<th align=\"right\">E<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>%50 ve %55<\/td>\n<td align=\"right\">800<\/td>\n<td align=\"right\">900<\/td>\n<td align=\"right\">1.050<\/td>\n<td align=\"right\">1.400<\/td>\n<td align=\"right\">2.000<\/td>\n<td align=\"right\">&gt;2.000<\/td>\n<\/tr>\n<tr>\n<td>%60 ve %65<\/td>\n<td align=\"right\">850<\/td>\n<td align=\"right\">950<\/td>\n<td align=\"right\">1.100<\/td>\n<td align=\"right\">1.450<\/td>\n<td align=\"right\">2.050<\/td>\n<td align=\"right\">&gt;2.050<\/td>\n<\/tr>\n<tr>\n<td>%70 ve %75<\/td>\n<td align=\"right\">950<\/td>\n<td align=\"right\">1.100<\/td>\n<td align=\"right\">1.250<\/td>\n<td align=\"right\">1.550<\/td>\n<td align=\"right\">2.150<\/td>\n<td align=\"right\">&gt;2.150<\/td>\n<\/tr>\n<tr>\n<td>%80 ve %85<\/td>\n<td align=\"right\">1.050<\/td>\n<td align=\"right\">1.250<\/td>\n<td align=\"right\">1.450<\/td>\n<td align=\"right\">1.800<\/td>\n<td align=\"right\">2.400<\/td>\n<td align=\"right\">&gt;2.400<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Kaynak: ECP 11 FIL 2026, Tablo 1, bas\u0131l\u0131 sayfa 9. Bunlar se\u00e7ilmi\u015f aral\u0131klard\u0131r; her partik\u00fcl grubu i\u00e7in tam tablo de\u011fildir. Di\u011fer aral\u0131klar i\u00e7in kurallar\u0131n tamam\u0131n\u0131 ve belgelendirilmi\u015f \u00fcr\u00fcn kayd\u0131n\u0131 kullan\u0131n. <a href=\"https:\/\/www.eurovent-certification.com\/media\/images\/TCR\/_EC\/TCR_ECP_FIL_2026_6a1954ee8ba76.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Resm\u00ee s\u0131n\u0131f tablosu<\/a><\/p>\n<p>%50\u201365 aral\u0131\u011f\u0131n\u0131 tek sat\u0131rda birle\u015ftirmeyin. \u00d6rnek bir 840 kWh\/y\u0131l derecelendirme de\u011feri, ePM1 50\/55 aral\u0131\u011f\u0131nda A, 60\/65 aral\u0131\u011f\u0131nda ise A+ sonucu verir. Bu, hesab\u0131n de\u011fi\u015fti\u011fi anlam\u0131na gelmez. Kar\u015f\u0131la\u015ft\u0131rma aral\u0131\u011f\u0131 de\u011fi\u015fti\u011fi i\u00e7in s\u0131n\u0131f s\u0131n\u0131r\u0131 de\u011fi\u015fmi\u015ftir.<\/p>\n<h2>Partik\u00fcl gruplar\u0131n\u0131n s\u0131n\u0131rlar\u0131 da farkl\u0131d\u0131r<\/h2>\n<p>%50\/55 aral\u0131\u011f\u0131nda 2026 A+ s\u0131n\u0131rlar\u0131 ePM1 i\u00e7in 800 kWh\/y\u0131l, ePM2.5 i\u00e7in 700 ve ePM10 i\u00e7in 450\u2019dir. Gruplar ince par\u00e7ac\u0131klar\u0131 ayn\u0131 oranda tuttuklar\u0131n\u0131 g\u00f6stermez. Al\u0131c\u0131, yaln\u0131zca daha k\u00fc\u00e7\u00fck enerji rakam\u0131 elde etmek i\u00e7in gerekli filtrasyon s\u0131n\u0131f\u0131n\u0131 d\u00fc\u015f\u00fcrmemelidir. <a href=\"https:\/\/www.eurovent-certification.com\/media\/images\/TCR\/_EC\/TCR_ECP_FIL_2026_6a1954ee8ba76.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 2026 kurallar\u0131, sayfa 9\u201310\u2019daki Tablo 1\u2019ler<\/a><\/p>\n<p>\u00d6nce filtrasyon gereklili\u011fine karar verin. Ard\u0131ndan uygun \u00fcr\u00fcnlerin enerji performans\u0131n\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n. Tasar\u0131mc\u0131 de\u011fi\u015fmi\u015f bir filtrasyon d\u00fczenini kabul ediyorsa t\u00fcm kademelerin performans\u0131 ve direnci dahil olmak \u00fczere bu d\u00fczeni b\u00fct\u00fcn bir \u00f6neri olarak de\u011ferlendirin.<\/p>\n<p>Eski elektronik tablolara dikkat edin. Birka\u00e7 y\u0131l \u00f6nce kopyalanm\u0131\u015f tablo farkl\u0131 test standard\u0131, verim grupland\u0131rmas\u0131 veya e\u015fikler kullanabilir. \u0130hale de\u011ferlendirmesinde kullan\u0131lan her tabloyla kaynak bask\u0131s\u0131n\u0131 birlikte tutun.<\/p>\n<h2>Enerji s\u0131n\u0131f\u0131n\u0131n avro cinsinden maliyeti<\/h2>\n<p>Her enerji s\u0131n\u0131f\u0131 bir t\u00fcketim aral\u0131\u011f\u0131n\u0131 kapsar; bu nedenle ayn\u0131 s\u0131n\u0131ftaki b\u00fct\u00fcn filtrelerin enerji maliyeti ayn\u0131 de\u011fildir. Anlaml\u0131 maliyet kar\u015f\u0131la\u015ft\u0131rmas\u0131 i\u00e7in ger\u00e7ek derecelendirme enerji de\u011ferini kullan\u0131n.<\/p>\n<p>750, 880 ve 1.040 kWh\/y\u0131l de\u011ferlerine sahip \u00fc\u00e7 temsili ePM1 %50 \u00fcr\u00fcn\u00fc ele alal\u0131m. S\u0131n\u0131flar\u0131 A+, A ve B\u2019dir. Varsay\u0131lan \u20ac0,20\/kWh elektrik fiyat\u0131nda referans ko\u015fullardaki enerji maliyetleri s\u0131ras\u0131yla y\u0131lda \u20ac150, \u20ac176 ve \u20ac208 olur.<\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>\u00d6rnek \u00fcr\u00fcn<\/th>\n<th align=\"right\">S\u0131n\u0131fland\u0131rmada kullan\u0131lan enerji de\u011feri<\/th>\n<th>50\/55 aral\u0131\u011f\u0131ndaki s\u0131n\u0131f<\/th>\n<th align=\"right\">\u20ac0,20\/kWh ile enerji maliyeti<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>A<\/td>\n<td align=\"right\">750 kWh\/y\u0131l<\/td>\n<td>A+<\/td>\n<td align=\"right\">\u20ac150\/y\u0131l<\/td>\n<\/tr>\n<tr>\n<td>B<\/td>\n<td align=\"right\">880 kWh\/y\u0131l<\/td>\n<td>A<\/td>\n<td align=\"right\">\u20ac176\/y\u0131l<\/td>\n<\/tr>\n<tr>\n<td>C<\/td>\n<td align=\"right\">1.040 kWh\/y\u0131l<\/td>\n<td>B<\/td>\n<td align=\"right\">\u20ac208\/y\u0131l<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Bu \u00f6rnekte A ile C aras\u0131ndaki enerji maliyeti fark\u0131, belirtilen derecelendirme ve tarife varsay\u0131mlar\u0131nda y\u0131lda \u20ac58\u2019dir. Ulpatek kurulumunda \u00f6l\u00e7\u00fclm\u00fc\u015f tasarruf de\u011fildir. Tam maliyet kar\u015f\u0131la\u015ft\u0131rmas\u0131 i\u00e7in sat\u0131n alma fiyat\u0131, i\u015f\u00e7ilik, bertaraf ve de\u011fi\u015fim s\u0131kl\u0131\u011f\u0131ndaki farklar eklenmelidir.<\/p>\n<p>Ayn\u0131 harf aral\u0131\u011f\u0131ndaki iki \u00fcr\u00fcn\u00fcn enerji de\u011ferleri de farkl\u0131 olabilir. Her iki teklifte de A+ yaz\u0131yorsa enerji performanslar\u0131n\u0131n ayn\u0131 oldu\u011fu sonucuna varmadan \u00f6nce kWh rakamlar\u0131n\u0131 isteyin.<\/p>\n<h2>Binan\u0131z neden farkl\u0131 sonu\u00e7 verebilir?<\/h2>\n<p>Ger\u00e7ek kurulum daha az saat \u00e7al\u0131\u015fabilir, ba\u015fka hava debisi kullanabilir, farkl\u0131 fan verimine sahip olabilir veya filtreleri referans testten farkl\u0131 bi\u00e7imde y\u00fckleyebilir. Kontrolleri de \u00f6nemlidir. Sabit debili sistemde daha d\u00fc\u015f\u00fck diren\u00e7li filtre, gereken fan giri\u015f g\u00fcc\u00fcn\u00fc azaltabilir; sabit fan h\u0131z\u0131nda ise etkinin bir b\u00f6l\u00fcm\u00fc artan hava debisi olarak g\u00f6r\u00fclebilir.<\/p>\n<p>Eurovent 4\/24, \u00e7al\u0131\u015fma ko\u015fullar\u0131ndaki de\u011ferlendirmeyi ele al\u0131r ve bu ayr\u0131m\u0131 a\u00e7\u0131klar. \u00dcr\u00fcn kar\u015f\u0131la\u015ft\u0131rmas\u0131n\u0131 saha tahminine d\u00f6n\u00fc\u015ft\u00fcr\u00fcrken kullan\u0131n. Belgelendirilmi\u015f dereceyi \u00fcr\u00fcn kar\u015f\u0131la\u015ft\u0131rmas\u0131 olarak koruyun; ard\u0131ndan bina hesab\u0131nda kullan\u0131lan varsay\u0131mlar\u0131 a\u00e7\u0131k\u00e7a belirtin. <a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/publications-files\/eurovent-rec-4-24-energy-consumption-evaluation-2023-en-update-1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/24-2023, Update 1<\/a><\/p>\n<p>Bu, yayg\u0131n bir kestirme yolu da \u00f6nler: derecelendirme de\u011ferini filtre adediyle \u00e7arp\u0131p sonucu garantili y\u0131ll\u0131k tasarruf olarak sunmak. Adetleri \u00e7arpmak kolayd\u0131r; \u00e7al\u0131\u015fma ko\u015fullar\u0131n\u0131n yine de gerek\u00e7elendirilmesi gerekir.<\/p>\n<h2>Etiketin teklif edilen \u00fcr\u00fcn\u00fc kapsad\u0131\u011f\u0131n\u0131 kontrol edin<\/h2>\n<p>Eurovent FIL program\u0131n\u0131n tan\u0131ml\u0131 bir \u00fcr\u00fcn kapsam\u0131 vard\u0131r. Kat\u0131l\u0131mc\u0131 \u015firketin \u00fcretti\u011fi her filtre i\u00e7in genel enerji sertifikas\u0131 de\u011fildir. ISO Coarse filtreler ve aktif karbonla birle\u015ftirilmi\u015f filtreler, program sayfas\u0131nda belirtilen kapsam d\u0131\u015f\u0131 \u00fcr\u00fcnler aras\u0131ndad\u0131r. HEPA s\u0131n\u0131fland\u0131rmas\u0131 farkl\u0131 bir performans \u00e7er\u00e7evesine aittir. <a href=\"https:\/\/www.eurovent-certification.com\/en\/third-party-certification\/certification-programmes\/fil\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent FIL program kapsam\u0131<\/a><\/p>\n<p>Markay\u0131, modeli, \u00f6l\u00e7\u00fcleri, nominal hava debisini, partik\u00fcl s\u0131n\u0131f\u0131n\u0131 ve enerji de\u011ferini g\u00fcncel belgelendirilmi\u015f listeyle e\u015fle\u015ftirin. Standart tam boy modelin etiketi, farkl\u0131 derinlikteki veya \u00f6zel yap\u0131daki \u00fcr\u00fcne geli\u015fig\u00fczel aktar\u0131lmamal\u0131d\u0131r.<\/p>\n<p>Teklif \u00fcr\u00fcn ailesine dayal\u0131 beyan \u00f6neriyorsa sunulan \u00fcr\u00fcn\u00fcn bu aileye ve ilgili kurallara nas\u0131l dahil oldu\u011funu sorun. G\u00fcncel bir sertifika, ancak incelenen \u00fcr\u00fcn\u00fc kaps\u0131yorsa de\u011ferlendirmede kullan\u0131labilir.<\/p>\n<h2>Enerji s\u0131n\u0131f\u0131n\u0131n yan\u0131nda t\u00fcketim de\u011ferini de isteyin<\/h2>\n<p>B\u00f6ylece al\u0131c\u0131 iki net karar verebilir: filtrenin hava kalitesi gereklili\u011fini kar\u015f\u0131lay\u0131p kar\u015f\u0131lamad\u0131\u011f\u0131 ve maliyetinin ayn\u0131 gereklili\u011fi kar\u015f\u0131layan di\u011fer \u00fcr\u00fcnlerle nas\u0131l kar\u015f\u0131la\u015ft\u0131r\u0131ld\u0131\u011f\u0131. A+ yararl\u0131 bir g\u00f6stergedir. Sat\u0131n alma incelemesini sa\u011flam bir zemine oturtan ise tam performans kayd\u0131d\u0131r.<\/p>\n<h2>Kaynaklar<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.eurovent-certification.com\/media\/images\/TCR\/_EC\/TCR_ECP_FIL_2026_6a1954ee8ba76.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 2026 kurallar\u0131, sayfa 9\u201310\u2019daki Tablo 1\u2019ler<\/a><\/li>\n<li><a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/publications-files\/eurovent-rec-4-21-energy-efficiency-evaluation-of-air-filters-for-general-ventilation-purposes-fourth-edition-2019-en.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/21, b\u00f6l\u00fcmler 2\u20133<\/a><\/li>\n<li><a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/publications-files\/eurovent-rec-4-24-energy-consumption-evaluation-2023-en-update-1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/24-2023, Update 1<\/a><\/li>\n<li><a href=\"https:\/\/www.eurovent-certification.com\/en\/third-party-certification\/certification-programmes\/fil\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent FIL program kapsam\u0131<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Eurovent enerji s\u0131n\u0131rlar\u0131n\u0131 verim aral\u0131\u011f\u0131na g\u00f6re okuyun; y\u0131ll\u0131k kWh de\u011ferini, elektrik maliyetini ve standart derecelendirmenin s\u0131n\u0131rlar\u0131n\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[457],"tags":[],"class_list":["post-15095","post","type-post","status-publish","format-standard","hentry","category-guide-energy-tr"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15095","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/comments?post=15095"}],"version-history":[{"count":1,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15095\/revisions"}],"predecessor-version":[{"id":15687,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15095\/revisions\/15687"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/media?parent=15095"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/categories?post=15095"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/tags?post=15095"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}