{"id":15094,"date":"2026-10-28T10:00:00","date_gmt":"2026-10-28T07:00:00","guid":{"rendered":"https:\/\/www.ulpatek.com\/?p=15094"},"modified":"2026-10-01T14:05:49","modified_gmt":"2026-10-01T11:05:49","slug":"hvac-filtresi-alirken-ilk-soru-gidaya-uygunluk-sertifikaniz-var-mi","status":"publish","type":"post","link":"https:\/\/www.ulpatek.com\/tr\/filtre-teknolojisi\/hvac-filtresi-alirken-ilk-soru-gidaya-uygunluk-sertifikaniz-var-mi\/","title":{"rendered":"HVAC filtresi al\u0131rken ilk soru \u201cG\u0131daya uygunluk sertifikan\u0131z var m\u0131?\u201d olmamal\u0131"},"content":{"rendered":"<p>G\u0131da fabrikas\u0131n\u0131n havaland\u0131rma filtresi i\u00e7in genel bir \u201cg\u0131daya uygunluk sertifikas\u0131\u201d talebi, neyin kan\u0131tlanmas\u0131 gerekti\u011fini tan\u0131mlamaz. \u00d6nce filtrenin nerede kullan\u0131laca\u011f\u0131n\u0131, g\u0131dan\u0131n hangi ko\u015fullarda havaya maruz kald\u0131\u011f\u0131n\u0131 ve kontaminasyon risklerini belirleyin. Ard\u0131ndan filtrasyon performans\u0131n\u0131, filtre yap\u0131s\u0131n\u0131 ve ge\u00e7erli g\u0131da temas\u0131 gerekliliklerinin kar\u015f\u0131land\u0131\u011f\u0131n\u0131 g\u00f6steren belgeleri isteyin.<\/p>\n<p>Conta malzemesi beyan\u0131, filtre verim raporu ve klima santrali hijyen de\u011ferlendirmesi farkl\u0131 \u00f6zellikleri de\u011ferlendirir. Her belge, de\u011ferlendirdi\u011finiz \u00fcr\u00fcn\u00fc ve kullan\u0131m\u0131 kapsamal\u0131d\u0131r.<\/p>\n<h2>\u00d6nce hangi hava sistemini kastetti\u011finizi belirleyin<\/h2>\n<p>G\u0131da tesislerinde hava \u00e7e\u015fitli \u015fekillerde kullan\u0131l\u0131r. Bina havaland\u0131rmas\u0131, insanlar\u0131n bulundu\u011fu mek\u00e2nlar\u0131 ve \u00fcretim alanlar\u0131n\u0131 besler. Proses havas\u0131, \u00fcretimin bir par\u00e7as\u0131 olarak \u00fcr\u00fcnle temas edebilir. Bas\u0131n\u00e7l\u0131 hava ekipman\u0131 \u00e7al\u0131\u015ft\u0131rabilir veya \u00fcr\u00fcnle temas eden bir uygulamaya girebilir. Yaln\u0131zca hepsinde \u201chava\u201d s\u00f6zc\u00fc\u011f\u00fc ge\u00e7iyor diye bu farkl\u0131 kullan\u0131mlar i\u00e7in ayn\u0131 \u015fartname uygulanmamal\u0131d\u0131r.<\/p>\n<p>EHEDG Guideline 47, g\u0131da fabrikalar\u0131n\u0131n bina havaland\u0131rmas\u0131 ve hava kalitesi kontrol\u00fc i\u00e7in hava i\u015fleme sistemlerini ele al\u0131r. Yay\u0131mlanm\u0131\u015f kapsam\u0131 proses havas\u0131 beslemelerini, bas\u0131n\u00e7l\u0131 havay\u0131 ve belirli egzoz sistemlerini hari\u00e7 tutar. ISO 8573-1 ise bas\u0131n\u00e7l\u0131 havan\u0131n safl\u0131\u011f\u0131n\u0131 par\u00e7ac\u0131k, su ve ya\u011f a\u00e7\u0131s\u0131ndan s\u0131n\u0131fland\u0131r\u0131r. Dolay\u0131s\u0131yla bas\u0131n\u00e7l\u0131 hava safl\u0131k tan\u0131m\u0131, bina havaland\u0131rma filtresinin \u015fartnamesinin yerini tutmaz. <a href=\"https:\/\/www.ehedg.org\/guidelines-working-groups\/guidelines\/guidelines\/detail\/guidelines-on-air-handling-systems-in-the-food-industry-air-quality-control-for-building-ventilation\" target=\"_blank\" rel=\"noopener noreferrer\">EHEDG Guideline 47 kapsam\u0131<\/a>, <a href=\"https:\/\/www.iso.org\/standard\/46418.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 8573-1:2010<\/a><\/p>\n<p>Teklif istemeden \u00f6nce filtreyi basit bir hava ak\u0131\u015f \u015femas\u0131nda i\u015faretleyin. Havan\u0131n nereden geldi\u011fini, nereye gitti\u011fini ve filtre \u00e7\u0131k\u0131\u015f\u0131ndan sonraki alanda a\u00e7\u0131kta g\u0131da bulunup bulunmad\u0131\u011f\u0131n\u0131 g\u00f6sterin. Bu, tedarik\u00e7iyle kalite ekibinizin ayn\u0131 uygulamay\u0131 de\u011ferlendirmesine yard\u0131mc\u0131 olur.<\/p>\n<h2>AB g\u0131da hijyeni kurallar\u0131 havaland\u0131rmadan ger\u00e7ekte ne ister?<\/h2>\n<p>\u0130lgili h\u00fck\u00fcmler kapsam\u0131ndaki g\u0131da tesisleri i\u00e7in Regulation (EC) No 852\/2004; uygun havaland\u0131rma, mekanik hava ak\u0131\u015f\u0131n\u0131n kirli alanlardan temiz alanlara y\u00f6nelmesinin \u00f6nlenmesi ve temizlik veya de\u011fi\u015fim gerektiren filtreler ile di\u011fer par\u00e7alara eri\u015fim ister. Ayr\u0131ca g\u0131da hijyenini, i\u015fletmeci sorumlulu\u011funu ve HACCP ilkelerine dayanan prosed\u00fcrleri i\u00e7eren daha geni\u015f bir sistem i\u00e7inde ele al\u0131r. Bir filtre sertifikas\u0131n\u0131 b\u00fct\u00fcn \u00fcretim ortam\u0131n\u0131n onay\u0131na d\u00f6n\u00fc\u015ft\u00fcrmez. <a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2004\/852\/oj\/eng\" target=\"_blank\" rel=\"noopener noreferrer\">Regulation (EC) No 852\/2004, Madde 5 ve Ek II, B\u00f6l\u00fcm I<\/a><\/p>\n<p>Filtre s\u0131n\u0131f\u0131n\u0131 se\u00e7meden \u00f6nce kurulumun nas\u0131l temiz tutulaca\u011f\u0131n\u0131 g\u00f6zden ge\u00e7irin. Filtre kutusu temizlenebilir mi? Birikmi\u015f kir temiz tarafa ta\u015f\u0131nmadan filtre de\u011fi\u015ftirilebilir mi? Conta, oturma d\u00fczenine uyuyor mu? Temizlik, filtreyi veya \u00e7er\u00e7eveyi neme ya da kimyasallara maruz b\u0131rakacak m\u0131?<\/p>\n<p>Bu sorular filtre al\u0131m\u0131n\u0131 tesisin hijyen plan\u0131na ba\u011flar. Yaln\u0131zca bro\u015f\u00fcr\u00fcnde \u201chijyenik\u201d s\u00f6zc\u00fc\u011f\u00fc var diye bir yap\u0131 se\u00e7meden \u00f6nce yan\u0131tlanmal\u0131d\u0131r.<\/p>\n<h2>Regulation 1935\/2004 hava filtresine uygulan\u0131r m\u0131?<\/h2>\n<p>Ama\u00e7lanan ve \u00f6ng\u00f6r\u00fclebilir kullan\u0131ma ba\u011fl\u0131d\u0131r. Regulation (EC) No 1935\/2004; g\u0131dayla temas etmesi ama\u00e7lanan, zaten ama\u00e7lanan g\u0131da temas\u0131nda olan veya normal ya da \u00f6ng\u00f6r\u00fclebilir ko\u015fullarda g\u0131dayla temas etmesi ya da ona bile\u015fen aktarmas\u0131 makul olarak beklenen malzeme ve e\u015fyalar\u0131 kapsar. Hava filtresi i\u00e7in bu kapsam\u0131 ger\u00e7ek uygulamaya g\u00f6re de\u011ferlendirin. HVAC \u00fcr\u00fcn\u00fc olmas\u0131 kendili\u011finden kapsam d\u0131\u015f\u0131nda b\u0131rakmaz; g\u0131da fabrikas\u0131na tak\u0131lmas\u0131 da kendili\u011finden kapsama dahil etmez. <a href=\"https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/?uri=consolidation%3A2004R1935%2F20210327_0020010\" target=\"_blank\" rel=\"noopener noreferrer\">Regulation (EC) No 1935\/2004, Madde 1<\/a><\/p>\n<p>Genel bina alan\u0131na hizmet eden uzaktaki filtre ile a\u00e7\u0131k \u00fcr\u00fcne do\u011fru hava sa\u011flayan filtre farkl\u0131 incelemeler gerektirir. Mesafe tek ba\u015f\u0131na konuyu \u00e7\u00f6zmez. Normal veya \u00f6ng\u00f6r\u00fclebilir kullan\u0131m ko\u015fullar\u0131nda filtreden gelen maddelerin g\u0131daya ula\u015fmas\u0131n\u0131n makul olarak beklenip beklenemeyece\u011fini de\u011ferlendirin. Bu sonuca nas\u0131l ula\u015f\u0131ld\u0131\u011f\u0131n\u0131 kaydedin.<\/p>\n<p>G\u0131dayla temas kurallar\u0131 ge\u00e7erliyse malzemeye \u00f6zg\u00fc ilgili d\u00fczenlemeler ve ulusal h\u00fck\u00fcmler de dikkate al\u0131nmal\u0131d\u0131r. Regulation (EU) No 10\/2011 kapsam\u0131ndaki plastik g\u0131da temas malzemeleri i\u00e7in Komisyon, ilgili bilgilerin \u00fcretim zinciri boyunca iletilmesinde kullan\u0131lan bir uygunluk beyan\u0131n\u0131 a\u00e7\u0131klar. Destekleyici belgeler bu beyan\u0131 do\u011frulamal\u0131 ve talep edildi\u011finde denetim makamlar\u0131na sunulabilmelidir. Malzeme, kullan\u0131m ve hukuki dayanak belirtilmeden \u201cg\u0131daya uygundur\u201d demek, e\u015fde\u011fer bir a\u00e7\u0131klama de\u011fildir. <a href=\"https:\/\/food.ec.europa.eu\/food-safety\/chemical-safety\/food-contact-materials\/legislation_en\" target=\"_blank\" rel=\"noopener noreferrer\">Avrupa Komisyonu: g\u0131dayla temas mevzuat\u0131<\/a><\/p>\n<h2>Filtrenin tamam\u0131n\u0131 kapsayan belgeleri isteyin<\/h2>\n<p>Hava filtresi; medya, \u00e7er\u00e7eve, yap\u0131\u015ft\u0131r\u0131c\u0131 veya dolgu bile\u015fi\u011fi, ay\u0131r\u0131c\u0131lar ve conta i\u00e7erebilir. Tek bir bile\u015fene ait belge, filtrenin tamam\u0131n\u0131n ba\u015fka bir kullan\u0131ma uygun oldu\u011funu tek ba\u015f\u0131na g\u00f6stermez.<\/p>\n<p>Tedarik\u00e7iye her belgenin tam olarak neyi kapsad\u0131\u011f\u0131n\u0131 sorun. Beyan bir s\u0131zd\u0131rmazl\u0131k eleman\u0131yla ilgiliyse bu s\u0131n\u0131r\u0131 kaydedin. Test tamamlanm\u0131\u015f filtreyi kaps\u0131yorsa modelini, yap\u0131s\u0131n\u0131 ve belirtilen ko\u015fullar\u0131 kontrol edin. \u0130ddia bir klima santralini kaps\u0131yorsa \u00f6nerilen filtre ve montaj konfig\u00fcrasyonunun buna dahil olup olmad\u0131\u011f\u0131n\u0131 kontrol edin.<\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>Yan\u0131tlanacak soru<\/th>\n<th>\u0130stenebilecek belge veya test verisi<\/th>\n<th>Tek ba\u015f\u0131na neyi g\u00f6stermez?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Filtre, belirtilen par\u00e7ac\u0131k giderimini sa\u011fl\u0131yor mu?<\/td>\n<td>Beyan edilen s\u0131n\u0131f, ge\u00e7erli test standard\u0131 ve performans raporu<\/td>\n<td>Her malzemenin g\u0131da temas\u0131na uygunlu\u011funu<\/td>\n<\/tr>\n<tr>\n<td>Kuruluma uyuyor ve s\u0131zd\u0131rmazl\u0131k sa\u011fl\u0131yor mu?<\/td>\n<td>\u00d6l\u00e7\u00fcler, \u00e7izim, conta d\u00fczeni ve montaj talimatlar\u0131<\/td>\n<td>Havaland\u0131rma sisteminin tamam\u0131n\u0131n hijyenini<\/td>\n<\/tr>\n<tr>\n<td>Yap\u0131, ortama uygun mu?<\/td>\n<td>Malzeme tan\u0131m\u0131 ve belirtilen s\u0131cakl\u0131k, nem ve kimyasal s\u0131n\u0131rlar\u0131<\/td>\n<td>Bu s\u0131n\u0131rlar\u0131n d\u0131\u015f\u0131ndaki ko\u015fullara uygunlu\u011funu<\/td>\n<\/tr>\n<tr>\n<td>G\u0131dayla temas uygunlu\u011fu de\u011ferlendirmesi gerekiyor mu?<\/td>\n<td>Belgelenmi\u015f kapsam de\u011ferlendirmesi ve ge\u00e7erli beyanlar veya destekleyici kan\u0131t<\/td>\n<td>Her g\u0131da veya s\u00fcre\u00e7 i\u00e7in evrensel onay\u0131<\/td>\n<\/tr>\n<tr>\n<td>Filtre hijyenik bi\u00e7imde elle\u00e7lenip de\u011fi\u015ftirilebilir mi?<\/td>\n<td>Elle\u00e7leme talimatlar\u0131 ve tesise \u00f6zg\u00fc bak\u0131m prosed\u00fcr\u00fc<\/td>\n<td>Prosed\u00fcr\u00fcn sahada do\u011fru uygulanmas\u0131n\u0131<\/td>\n<\/tr>\n<tr>\n<td>Tedarik edilen \u00fcr\u00fcn izlenebilir mi?<\/td>\n<td>Model kimli\u011fi ve kararla\u015ft\u0131r\u0131lm\u0131\u015f parti veya seri belgeleri<\/td>\n<td>Referans verilen \u00fcr\u00fcn\u00fcn \u00f6tesindeki performans iddialar\u0131n\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Eksik belgeleri belirlemek i\u00e7in bu kontrol listesini kullan\u0131n. Sertifika yaln\u0131zca kapsam\u0131na giren \u00f6zellikleri do\u011frular.<\/p>\n<h2>Filtreyi tesisin hijyen plan\u0131na dahil edin<\/h2>\n<p>EHEDG\u2019nin g\u0131da tesisi hava i\u015fleme sistemlerine ili\u015fkin a\u00e7\u0131k rehberi; \u00fcr\u00fcn riskini, hijyen b\u00f6lgelerini, uygun ekipman\u0131 ve bak\u0131m\u0131 vurgular. Teknik veya hijyenik eksiklik g\u00f6zlendi\u011finde inceleme ve de\u011fi\u015fime de dikkat \u00e7eker. Filtre se\u00e7imi bu genel yakla\u015f\u0131m\u0131n i\u00e7inde yer al\u0131r. <a href=\"https:\/\/www.ehedg.org\/fileadmin\/user_upload\/2017_07_EHEDG_Doc._47__Air_Handling_Article_3_Pages_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">EHEDG: g\u0131da tesisinde hava kalitesi ve kontrol\u00fc<\/a><\/p>\n<p>\u00d6rne\u011fin \u00fcr\u00fcn\u00fcn zaten kapal\u0131 ambalajda oldu\u011fu bir paketleme odas\u0131 i\u00e7in haz\u0131rlanm\u0131\u015f \u015fartname d\u00fc\u015f\u00fcn\u00fcn. \u015eimdi ayn\u0131 \u015fartnamenin, son i\u015fleminden sonra a\u00e7\u0131k \u00fcr\u00fcnle \u00e7al\u0131\u015f\u0131lan alana kopyaland\u0131\u011f\u0131n\u0131 varsayal\u0131m. Filtre ayn\u0131 olabilir, ancak kontaminasyon olay\u0131n\u0131n sonucu farkl\u0131d\u0131r. \u0130kinci alan i\u00e7in kopyalanm\u0131\u015f bir onay sat\u0131r\u0131 yerine ayr\u0131 bir de\u011ferlendirme yap\u0131lmal\u0131d\u0131r.<\/p>\n<p>Malzeme de\u011fi\u015fikliklerini de inceleyin. \u00c7er\u00e7eve, yap\u0131\u015ft\u0131r\u0131c\u0131 veya conta de\u011fi\u015firse \u00f6zg\u00fcn yap\u0131y\u0131 de\u011ferlendiren ekibe bildirin. \u00dcr\u00fcn tan\u0131m\u0131n\u0131 ve destekleyici belgeleri g\u00fcncelleyin; b\u00f6ylece belgeler, ger\u00e7ekten tedarik edilen \u00fcr\u00fcn\u00fcn g\u00fcncel \u00f6zelliklerini g\u00f6stersin.<\/p>\n<p>VDI 6022 Part 1, havaland\u0131rma ve iklimlendirme sistemleri ile \u00fcnitelerinin hijyen gerekliliklerini ele al\u0131r. \u015eartname buna g\u00f6re kan\u0131t istiyorsa \u00fcr\u00fcn\u00fc ve ger\u00e7ekten de\u011ferlendirilen y\u00f6nleri belirleyin. VDI 6022 atf\u0131, genel bir g\u0131dayla temas beyan\u0131 olarak sunulmamal\u0131d\u0131r. <a href=\"https:\/\/www.dinmedia.de\/en\/technical-rule\/vdi-6022-blatt-1\/279023701\" target=\"_blank\" rel=\"noopener noreferrer\">VDI 6022 Part 1:2018-01<\/a><\/p>\n<h2>Filtre tedarik\u00e7inize g\u00f6nderebilece\u011finiz daha iyi bir talep<\/h2>\n<p>Belgeleri s\u0131ralamadan \u00f6nce uygulamay\u0131 tan\u0131mlay\u0131n:<\/p>\n<p>\u201cFiltre, belirtilen hava debisinde bu \u00fcretim alan\u0131na hizmet edecektir. Filtre \u00e7\u0131k\u0131\u015f\u0131ndan sonraki \u015fu noktalarda g\u0131da a\u00e7\u0131kta bulunmaktad\u0131r. L\u00fctfen \u00f6nerilen filtre yap\u0131s\u0131n\u0131, performans s\u0131n\u0131f\u0131n\u0131, \u00f6l\u00e7\u00fclerini, \u00e7al\u0131\u015fma s\u0131n\u0131rlar\u0131n\u0131 ve mevcut test belgelerini do\u011frulay\u0131n. Ama\u00e7lanan kullan\u0131mla ilgili g\u0131dayla temas gerekliliklerini belirtin ve ileri s\u00fcr\u00fclen belirli iddialar\u0131 destekleyen kan\u0131tlar\u0131 sa\u011flay\u0131n.\u201d<\/p>\n<h2>Sat\u0131n alma ve kalite ekiplerinden sorular<\/h2>\n<h3>H14, filtrenin g\u0131daya uygun oldu\u011fu anlam\u0131na m\u0131 gelir?<\/h3>\n<p>H14 bir filtrasyon s\u0131n\u0131fland\u0131rmas\u0131d\u0131r. Filtredeki her malzemeyi tan\u0131mlamaz veya her g\u0131da s\u00fcrecine uygunlu\u011fu g\u00f6stermez. Performans kan\u0131t\u0131n\u0131 ve uygulamaya \u00f6zg\u00fc yap\u0131 de\u011ferlendirmesini ayr\u0131 ayr\u0131 isteyin. <a href=\"https:\/\/www.dinmedia.de\/en\/standard\/din-en-1822-1\/297837528\" target=\"_blank\" rel=\"noopener noreferrer\">EN 1822-1:2019 kapsam\u0131<\/a><\/p>\n<h3>Uygunlu\u011fu g\u00f6stermek i\u00e7in paslanmaz \u00e7elik yeterli mi?<\/h3>\n<p>Bu, \u00e7er\u00e7eve malzemesini tan\u0131mlar; filtrenin b\u00fct\u00fcn yap\u0131s\u0131n\u0131 veya \u00e7al\u0131\u015fma ko\u015fullar\u0131n\u0131 de\u011fil. Medya, s\u0131zd\u0131rmazl\u0131k elemanlar\u0131, yap\u0131\u015ft\u0131r\u0131c\u0131lar, montaj ve \u00f6ng\u00f6r\u00fclen temizlik ko\u015fullar\u0131 yine de de\u011ferlendirilmelidir.<\/p>\n<h3>Sertifika istemeyi b\u0131rakmal\u0131 m\u0131y\u0131z?<\/h3>\n<p>Hay\u0131r. Amac\u0131 ve kapsam\u0131 a\u00e7\u0131k belgeler isteyin. Her biri, \u00f6nerilen uygulamadaki ger\u00e7ek bir gereklili\u011fi veya kontaminasyon riskini kontrol etmenize yard\u0131mc\u0131 olmal\u0131d\u0131r.<\/p>\n<h2>Kaynaklar<\/h2>\n<ul>\n<li><a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2004\/852\/oj\/eng\" target=\"_blank\" rel=\"noopener noreferrer\">G\u0131da hijyenine ili\u015fkin Regulation (EC) No 852\/2004<\/a><\/li>\n<li><a href=\"https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/?uri=consolidation%3A2004R1935%2F20210327_0020010\" target=\"_blank\" rel=\"noopener noreferrer\">G\u0131dayla temas eden malzemelere ili\u015fkin Regulation (EC) No 1935\/2004<\/a><\/li>\n<li><a href=\"https:\/\/food.ec.europa.eu\/food-safety\/chemical-safety\/food-contact-materials\/legislation_en\" target=\"_blank\" rel=\"noopener noreferrer\">Avrupa Komisyonu: g\u0131dayla temas eden malzemeler mevzuat\u0131<\/a><\/li>\n<li><a href=\"https:\/\/www.ehedg.org\/guidelines-working-groups\/guidelines\/guidelines\/detail\/guidelines-on-air-handling-systems-in-the-food-industry-air-quality-control-for-building-ventilation\" target=\"_blank\" rel=\"noopener noreferrer\">EHEDG Guideline 47 kapsam\u0131<\/a><\/li>\n<li><a href=\"https:\/\/www.ehedg.org\/fileadmin\/user_upload\/2017_07_EHEDG_Doc._47__Air_Handling_Article_3_Pages_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">EHEDG\u2019nin g\u0131da tesisi hava i\u015fleme sistemleri hakk\u0131ndaki a\u00e7\u0131k makalesi<\/a><\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/46418.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 8573-1:2010<\/a><\/li>\n<li><a href=\"https:\/\/www.dinmedia.de\/en\/technical-rule\/vdi-6022-blatt-1\/279023701\" target=\"_blank\" rel=\"noopener noreferrer\">VDI 6022 Part 1:2018-01<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>\u201cG\u0131daya uygunluk sertifikas\u0131\u201d talebi neyin kan\u0131tlanaca\u011f\u0131n\u0131 s\u00f6ylemez. \u00d6nce kullan\u0131m yerini, g\u0131da maruziyetini ve malzemeyi belirleyin, sonra belge isteyin.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[463],"tags":[],"class_list":["post-15094","post","type-post","status-publish","format-standard","hentry","category-guide-applications-tr"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15094","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/comments?post=15094"}],"version-history":[{"count":1,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15094\/revisions"}],"predecessor-version":[{"id":15686,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15094\/revisions\/15686"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/media?parent=15094"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/categories?post=15094"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/tags?post=15094"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}