{"id":15088,"date":"2026-10-10T10:00:00","date_gmt":"2026-10-10T07:00:00","guid":{"rendered":"https:\/\/www.ulpatek.com\/?p=15088"},"modified":"2026-10-01T14:05:48","modified_gmt":"2026-10-01T11:05:48","slug":"hepa-filtre-test-sertifikasi-satir-satir-nasil-okunur","status":"publish","type":"post","link":"https:\/\/www.ulpatek.com\/tr\/filtre-teknolojisi\/hepa-filtre-test-sertifikasi-satir-satir-nasil-okunur\/","title":{"rendered":"HEPA filtre test sertifikas\u0131 sat\u0131r sat\u0131r nas\u0131l okunur?"},"content":{"rendered":"<p>\u0130\u015fe yarayan bir HEPA filtre sertifikas\u0131, belirli bir filtreyi test ko\u015fullar\u0131 ve sonu\u00e7lar\u0131yla ili\u015fkilendirir. Seri numaras\u0131n\u0131, hava debisini, MPPS esas\u0131n\u0131, toplam verimi ve ka\u00e7ak testi sonucunu birlikte okuyun; sayfada b\u00fcy\u00fck puntolarla \u00f6ne \u00e7\u0131kar\u0131lm\u0131\u015f \u201c%99,995\u201d de\u011feri tek ba\u015f\u0131na bu bilgileri vermez.<\/p>\n<p>A\u015fa\u011f\u0131daki a\u00e7\u0131klamal\u0131 H14 \u00f6rne\u011finde <strong>temsili rakamlar<\/strong> kullan\u0131lm\u0131\u015ft\u0131r. Tedarik edilmi\u015f bir filtrenin test sonucu de\u011fildir.<\/p>\n<h2>\u00d6nce elinizdeki belgenin ne oldu\u011funu belirleyin<\/h2>\n<p>Bu belgeler farkl\u0131 bilgileri do\u011frular:<\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>Belge<\/th>\n<th>Neyi g\u00f6sterir?<\/th>\n<th>Tek ba\u015f\u0131na neyi g\u00f6stermez?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u00dcr\u00fcn teknik f\u00f6y\u00fc<\/td>\n<td>Modelin beyan edilen s\u0131n\u0131f\u0131n\u0131, \u00f6l\u00e7\u00fclerini, malzemelerini ve \u00e7al\u0131\u015fma verilerini<\/td>\n<td>Teslim edilen belirli filtrenin sonucunu<\/td>\n<\/tr>\n<tr>\n<td>Medya test raporu<\/td>\n<td>Filtre \u00fcretiminde kullan\u0131lan d\u00fcz malzemenin \u00f6zelliklerini<\/td>\n<td>\u00dcretilmi\u015f filtrenin \u00e7er\u00e7evesinin, medyas\u0131n\u0131n ve birle\u015fimlerinin b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc<\/td>\n<\/tr>\n<tr>\n<td>Filtreye \u00f6zel test raporu<\/td>\n<td>Kimli\u011fi belirlenmi\u015f tek bir filtre eleman\u0131yla ili\u015fkili kay\u0131tl\u0131 sonu\u00e7lar\u0131<\/td>\n<td>Filtrenin daha sonraki montaj\u0131n\u0131n b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc<\/td>\n<\/tr>\n<tr>\n<td>Monte edilmi\u015f filtre test raporu<\/td>\n<td>Filtre sisteminin monte edildi\u011fi yerdeki sonu\u00e7lar\u0131n\u0131<\/td>\n<td>\u00dcreticinin \u00f6zg\u00fcn s\u0131n\u0131fland\u0131rma kayd\u0131n\u0131n yerini tuttu\u011funu<\/td>\n<\/tr>\n<tr>\n<td>Y\u00f6netim sistemi sertifikas\u0131<\/td>\n<td>Belgelendirilmi\u015f y\u00f6netim sisteminin kapsam\u0131n\u0131<\/td>\n<td>Tek bir filtrenin verimini veya ka\u00e7ak sonucunu<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>EN 1822-1:2019, medya belgelerini H ve U grubu filtre elemanlar\u0131yla normalde verilen belgelerden ay\u0131r\u0131r. Ayr\u0131ca rapor gerekliliklerini ilgili test y\u00f6ntemleriyle ili\u015fkilendirir. Yaln\u0131zca ba\u015fl\u0131\u011f\u0131nda \u201cSertifika\u201d yazan bir belge yerine, kontrol etmek istedi\u011finiz bilgiyi i\u00e7eren kayd\u0131 isteyin. <a href=\"https:\/\/landingpage.bsigroup.com\/LandingPage\/Undated?UPI=000000000001386856\" target=\"_blank\" rel=\"noopener noreferrer\">EN 1822-1:2019, b\u00f6l\u00fcm 8<\/a><\/p>\n<h2>1. Sonucu okumadan \u00f6nce raporla filtreyi e\u015fle\u015ftirin<\/h2>\n<p>\u00d6nce \u00fcretici, model ve seri numaras\u0131n\u0131 kontrol edin. Bunlar\u0131 fiziksel etiketle ve teslimat belgeleriyle kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/p>\n<p>Sevkiyatta ayn\u0131 \u00f6l\u00e7\u00fclerde \u00e7ok say\u0131da filtre varsa seri numaras\u0131 \u00f6zellikle \u00f6nemlidir. \u00d6l\u00e7\u00fcleri do\u011fru olan bir H14 raporu bile ba\u015fka bir filtreye aitse yanl\u0131\u015f kay\u0131tt\u0131r.<\/p>\n<p>\u00d6l\u00e7\u00fcleri ve konfig\u00fcrasyonu da kontrol edin. \u0130ki filtre ayn\u0131 en ve y\u00fcksekli\u011fe sahipken \u00e7er\u00e7eve derinlikleri, medya alanlar\u0131, s\u0131zd\u0131rmazl\u0131k d\u00fczenleri veya nominal hava debileri farkl\u0131 olabilir. Her seri numaras\u0131 i\u00e7in bir kay\u0131t tutun; bu kayd\u0131 raporla ve son montaj yeriyle ili\u015fkilendirin.<\/p>\n<p>Sertifikadaki seri numaras\u0131 e\u015fle\u015fmiyorsa do\u011fru kayd\u0131 isteyin. Bu bir evrak hatas\u0131 olabilir, ancak belge o filtrenin kan\u0131t\u0131 olarak kabul edilmeden \u00f6nce \u00e7\u00f6z\u00fclmelidir.<\/p>\n<h2>2. Standard\u0131, bask\u0131y\u0131 ve y\u00f6ntemi birlikte okuyun<\/h2>\n<p>\u201cEN 1822\u2019ye g\u00f6re test edilmi\u015ftir\u201d ifadesi, s\u0131n\u0131fland\u0131rma esas\u0131n\u0131 ve kullan\u0131lan y\u00f6ntemi tan\u0131mlayan bir rapordan daha az bilgi verir. G\u00fcncel EN B\u00f6l\u00fcm 1, EN 1822-1:2019\u2019dur; uluslararas\u0131 s\u0131n\u0131fland\u0131rma belgesi ise ISO 29463-1:2024\u2019t\u00fcr. <a href=\"https:\/\/landingpage.bsigroup.com\/LandingPage\/Undated?UPI=000000000001386856\" target=\"_blank\" rel=\"noopener noreferrer\">BSI yay\u0131n kayd\u0131<\/a>, <a href=\"https:\/\/www.iso.org\/standard\/84367.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 29463-1:2024<\/a><\/p>\n<p>Raporda bir standard\u0131n birden fazla b\u00f6l\u00fcm\u00fcne at\u0131f bulunabilir. S\u0131n\u0131fland\u0131rman\u0131n, medya testinin, ka\u00e7ak testinin ve toplam verim testinin g\u00f6revleri farkl\u0131d\u0131r. EN 1822-1:2019, EN 1822 B\u00f6l\u00fcm 2\u20135\u2019in yerini alan ilgili EN ISO 29463 test b\u00f6l\u00fcmleriyle birlikte kullan\u0131l\u0131r. Ge\u00e7erli bask\u0131lar\u0131 ve referanslar\u0131 kontrol edin; b\u00fct\u00fcn b\u00f6l\u00fcmlerin yay\u0131n y\u0131l\u0131n\u0131n ayn\u0131 olmas\u0131 gerekmez. <a href=\"https:\/\/landingpage.bsigroup.com\/LandingPage\/Undated?UPI=000000000001386856\" target=\"_blank\" rel=\"noopener noreferrer\">EN 1822-1:2019, \u00f6ns\u00f6z<\/a><\/p>\n<p>Y\u00f6ntem de \u00f6nemlidir. ISO 29463-4, belirli HEPA s\u0131n\u0131flar\u0131 i\u00e7in referans tarama y\u00f6ntemini ve di\u011fer ka\u00e7ak testi y\u00f6ntemlerini a\u00e7\u0131klar. EN 1822-1 tam olarak ayn\u0131 yollar\u0131 kabul etmez: 2019 bask\u0131s\u0131, s\u0131n\u0131fland\u0131rma prosed\u00fcr\u00fcnde aerosol fotometresiyle tarama testine izin vermez. Bu nedenle \u201cDOP testi yap\u0131lm\u0131\u015f\u201d veya \u201cka\u00e7ak testi yap\u0131lm\u0131\u015f\u201d ifadesi, sipari\u015finizde talep edilen s\u0131n\u0131fland\u0131rma y\u00f6nteminin uyguland\u0131\u011f\u0131n\u0131 tek ba\u015f\u0131na g\u00f6stermez. <a href=\"https:\/\/www.iso.org\/standard\/51838.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 29463-4:2011<\/a>, <a href=\"https:\/\/landingpage.bsigroup.com\/LandingPage\/Undated?UPI=000000000001386856\" target=\"_blank\" rel=\"noopener noreferrer\">EN 1822-1:2019, b\u00f6l\u00fcmler 7.4\u20137.5<\/a><\/p>\n<p>Sat\u0131n alma \u015fartnamesi her filtreye ayr\u0131 MPPS par\u00e7ac\u0131k say\u0131m\u0131 taramas\u0131 gerektiriyorsa buna ait kan\u0131t\u0131 kontrol edin. Her iki raporda da \u201cka\u00e7ak\u201d s\u00f6zc\u00fc\u011f\u00fc var diye farkl\u0131 bir y\u00f6ntemi kabul etmeyin.<\/p>\n<h2>3. Hava debisini ve bu debide \u00f6l\u00e7\u00fclen bas\u0131n\u00e7 kayb\u0131n\u0131 bulun<\/h2>\n<p>Bas\u0131n\u00e7 kayb\u0131 de\u011ferleri, \u00f6l\u00e7\u00fcld\u00fckleri hava debisi bilinmeden do\u011fru kar\u015f\u0131la\u015ft\u0131r\u0131lamaz.<\/p>\n<p>Raporda <strong>600 m\u00b3\/h ve 100 Pa<\/strong> verildi\u011fini varsayal\u0131m. Bas\u0131n\u00e7, bu test \u00e7al\u0131\u015fma noktas\u0131na ba\u011fl\u0131d\u0131r. Ayn\u0131 filtrenin ba\u015fka bir debide veya aylarca y\u00fcklendikten sonra 100 Pa\u2019da kalaca\u011f\u0131n\u0131n taahh\u00fcd\u00fc de\u011fildir.<\/p>\n<p>Benzer \u015fekilde verim sonucunun da tan\u0131ml\u0131 test ko\u015fullar\u0131 vard\u0131r. Test debisinin, s\u0131n\u0131fland\u0131r\u0131lan nominal debiyle ve belirtti\u011finiz \u00e7al\u0131\u015fma ko\u015fuluyla e\u015fle\u015fip e\u015fle\u015fmedi\u011fini kontrol edin. Uygulama raporlanan ko\u015fullar\u0131n d\u0131\u015f\u0131nda \u00e7al\u0131\u015f\u0131yorsa tek bir rakamdan \u00e7\u0131kar\u0131m yapmak yerine ilgili performans verilerini isteyin.<\/p>\n<p>Kabul sorular\u0131n\u0131 ayr\u0131 tutun:<\/p>\n<ul>\n<li>Filtre gerekli filtrasyon s\u0131n\u0131f\u0131n\u0131 kar\u015f\u0131l\u0131yor mu?<\/li>\n<li>Gerekli debideki bas\u0131n\u00e7 kayb\u0131, havaland\u0131rma tasar\u0131m\u0131 i\u00e7in kabul edilebilir mi?<\/li>\n<\/ul>\n<p>Bir filtre ilkini kar\u015f\u0131layabilir, ancak yine de fan veya terminal \u00fcnite i\u00e7in uygun olmayabilir.<\/p>\n<h2>4. MPPS\u2019nin neyi ifade etti\u011fini kontrol edin<\/h2>\n<p>MPPS, ilgili test ko\u015fullar\u0131nda en y\u00fcksek penetrasyonun g\u00f6r\u00fcld\u00fc\u011f\u00fc par\u00e7ac\u0131k boyutudur. Verim e\u011frisinin filtreyi en \u00e7ok zorlayan b\u00f6l\u00fcm\u00fcd\u00fcr; filtrenin yakalayabildi\u011fi en k\u00fc\u00e7\u00fck par\u00e7ac\u0131k de\u011fildir.<\/p>\n<p>\u00d6l\u00e7\u00fcmde kullan\u0131lan MPPS\u2019yi veya par\u00e7ac\u0131k boyutu aral\u0131\u011f\u0131n\u0131 ve bunun medya testinden nas\u0131l se\u00e7ildi\u011fini bulun. 0,18 \u00b5m gibi tek bir say\u0131 bulunabilir veya rapor say\u0131m kanal\u0131n\u0131 da tan\u0131mlayabilir. Laboratuvar, bu boyutun veya kanal\u0131n neden MPPS\u2019yi temsil etti\u011fini a\u00e7\u0131klayabilmelidir.<\/p>\n<p>ISO 29463-5:2022, 0,1 \u00b5m alt\u0131ndaki MPPS ve elektrik y\u00fckl\u00fc sentetik medyaya y\u00f6nelik h\u00fck\u00fcmler dahil olmak \u00fczere filtre eleman\u0131n\u0131n MPPS\u2019deki veriminin belirlenmesini kapsar. Bu nedenle her HEPA sertifikas\u0131nda \u201c0,3 \u00b5m\u201d yazmas\u0131 gerekti\u011fine dair genel kural yanl\u0131\u015ft\u0131r. <a href=\"https:\/\/www.iso.org\/standard\/77740.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 29463-5:2022<\/a><\/p>\n<p>Aerosol ad\u0131 da y\u00f6ntemin bir par\u00e7as\u0131d\u0131r. DEHS, PAO veya belirtilen ba\u015fka bir aerosol, test malzemesidir; filtre s\u0131n\u0131f\u0131 de\u011fildir. Aerosol ad\u0131 tek ba\u015f\u0131na par\u00e7ac\u0131k boyutland\u0131rmas\u0131n\u0131, cihaz tepkisini veya kabul s\u0131n\u0131rlar\u0131n\u0131 a\u00e7\u0131klamaz.<\/p>\n<h2>5. Toplam verimi yerel ka\u00e7ak sonucundan ay\u0131r\u0131n<\/h2>\n<p><strong>Toplam veya integral verim<\/strong>, filtre eleman\u0131n\u0131n testteki birle\u015fik giderme performans\u0131n\u0131 tan\u0131mlar. <strong>Yerel test<\/strong>, penetrasyonun ge\u00e7erli yerel kriteri a\u015ft\u0131\u011f\u0131 b\u00f6lgeleri arar.<\/p>\n<p>\u0130yi bir toplam sonu\u00e7, k\u00fc\u00e7\u00fck bir kusurlu b\u00f6lgeyi gizleyebilir. Yerel test bu sorunu kontrol eder. Ancak iki s\u0131n\u0131r farkl\u0131 oldu\u011fu i\u00e7in en d\u00fc\u015f\u00fck yerel verim, toplam verim alt s\u0131n\u0131r\u0131n\u0131n alt\u0131nda olup yine de testi ge\u00e7ebilir.<\/p>\n<p>Referans MPPS y\u00f6nteminde H14 i\u00e7in en y\u00fcksek toplam penetrasyon <strong>%0,005<\/strong>, en y\u00fcksek yerel penetrasyon ise <strong>%0,025<\/strong> d\u00fczeyindedir. Yanl\u0131\u015fl\u0131kla yerel sonucu toplam s\u0131n\u0131rla kar\u015f\u0131la\u015ft\u0131rmay\u0131n. <a href=\"https:\/\/www.vdma.eu\/documents\/34570\/14642203\/VDMA%2BLuftfilterinformation%2B%282019-10%29%2BFilterklassen%2Bder%2BRaumluft-%2Bund%2BEntstaubungstechnik%2Bim%2B%C3%9Cberblick%2B%284%29.pdf\/caae6004-906e-16fa-e059-a2dce0bb97b1?t=1618313384618\" target=\"_blank\" rel=\"noopener noreferrer\">VDMA filtre s\u0131n\u0131fland\u0131rma tablosu<\/a><\/p>\n<p>Her iki de\u011fer de y\u00fczde oldu\u011funda ili\u015fki basittir:<\/p>\n<p><strong>Verim (%) = 100 \u2212 penetrasyon (%)<\/strong><\/p>\n<p>%99,997 verim, %0,003 penetrasyona veya kesir olarak 0,00003\u2019e kar\u015f\u0131l\u0131k gelir. %0,00003 yazmak iki bi\u00e7imi kar\u0131\u015ft\u0131r\u0131r ve penetrasyonu 100 kat d\u00fc\u015f\u00fck g\u00f6sterir.<\/p>\n<h2>Temsili bir H14 sonucunu do\u011fru okumak<\/h2>\n<p>A\u015fa\u011f\u0131daki tablo bir e\u011fitim \u00f6rne\u011fidir. Bir filtrenin sevke uygun bulundu\u011funu g\u00f6steren sertifika de\u011fildir ve ger\u00e7ek bir Ulpatek \u00fcr\u00fcn\u00fc hakk\u0131nda iddia i\u00e7ermez.<\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>\u00d6rnek alan<\/th>\n<th>\u00d6rnek kay\u0131t<\/th>\n<th>\u00c7\u0131karman\u0131z gereken sonu\u00e7<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Kimlik<\/td>\n<td>EXAMPLE-001<\/td>\n<td>Ger\u00e7ek bir kay\u0131tta kullan\u0131ld\u0131\u011f\u0131nda ger\u00e7ek filtre etiketiyle e\u015fle\u015fmelidir<\/td>\n<\/tr>\n<tr>\n<td>Gerekli s\u0131n\u0131f<\/td>\n<td>EN 1822-1:2019\u2019a g\u00f6re H14<\/td>\n<td>De\u011ferlendirilen s\u0131n\u0131fland\u0131rmay\u0131 belirler<\/td>\n<\/tr>\n<tr>\n<td>Test hava debisi<\/td>\n<td>600 m\u00b3\/h<\/td>\n<td>Listelenen \u00f6l\u00e7\u00fcmlerin \u00e7al\u0131\u015fma noktas\u0131n\u0131 tan\u0131mlar<\/td>\n<\/tr>\n<tr>\n<td>Temiz durumdaki bas\u0131n\u00e7 kayb\u0131<\/td>\n<td>100 Pa<\/td>\n<td>O debi i\u00e7in kararla\u015ft\u0131r\u0131lan diren\u00e7le kar\u015f\u0131la\u015ft\u0131r\u0131lmal\u0131d\u0131r<\/td>\n<\/tr>\n<tr>\n<td>Test esas\u0131<\/td>\n<td>0,18 \u00b5m MPPS\u2019de par\u00e7ac\u0131k say\u0131m\u0131<\/td>\n<td>\u00d6rne\u011fin verim de\u011ferlendirme esas\u0131n\u0131 tan\u0131mlar<\/td>\n<\/tr>\n<tr>\n<td>Toplam verim<\/td>\n<td>%99,997<\/td>\n<td>%0,003 penetrasyona e\u015fde\u011ferdir; H14\u2019\u00fcn %0,005 toplam \u00fcst s\u0131n\u0131r\u0131n\u0131n alt\u0131ndad\u0131r<\/td>\n<\/tr>\n<tr>\n<td>En y\u00fcksek yerel penetrasyon<\/td>\n<td>%0,010<\/td>\n<td>Referans H14 yerel \u00fcst s\u0131n\u0131r\u0131 olan %0,025 de\u011ferinin alt\u0131ndad\u0131r<\/td>\n<\/tr>\n<tr>\n<td>Verim olarak ifade edilen yerel sonu\u00e7<\/td>\n<td>En az %99,990<\/td>\n<td>%0,010 en y\u00fcksek yerel penetrasyonla tutarl\u0131d\u0131r<\/td>\n<\/tr>\n<tr>\n<td>Tarama sonucu<\/td>\n<td>Belirtilen prosed\u00fcrde yerel uygunsuzluk tespit edilmedi<\/td>\n<td>Ger\u00e7ek tarama kapsam\u0131 ve test kayd\u0131yla desteklenmelidir<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>\u0130ki say\u0131sal performans sonucu da kendi H14 s\u0131n\u0131rlar\u0131yla uyumludur. %99,990 yerel verim, %99,995 de\u011ferinden d\u00fc\u015f\u00fck oldu\u011fu i\u00e7in <strong>ba\u015far\u0131s\u0131z say\u0131lmaz<\/strong>: ikinci rakam toplam verim gereklili\u011fidir.<\/p>\n<p>Bu rakamlar, her sonucun do\u011fru s\u0131n\u0131rla nas\u0131l kar\u015f\u0131la\u015ft\u0131r\u0131laca\u011f\u0131n\u0131 g\u00f6sterir. Ger\u00e7ek bir sertifika i\u00e7in t\u00fcm test ko\u015fullar\u0131, ekipman bilgileri ve gerekli kay\u0131tlar da bulunmal\u0131d\u0131r.<\/p>\n<h2>6. Tarama grafi\u011fini s\u00fcs olarak de\u011fil, veri olarak de\u011ferlendirin<\/h2>\n<p>Tarama raporu; tarama yollar\u0131n\u0131, koordinatlar\u0131, say\u0131mlar\u0131 veya \u00e7\u0131k\u0131\u015f y\u00fczeyinin haritas\u0131n\u0131 g\u00f6sterebilir. Renkleri yorumlamadan \u00f6nce a\u00e7\u0131klama anahtar\u0131n\u0131, birimleri, kabul e\u015fi\u011fini ve y\u00f6n\u00fc bulun.<\/p>\n<p>Renkli bir nokta, kabul edilebilir aral\u0131k i\u00e7indeki g\u00f6rece y\u00fcksek bir say\u0131m\u0131 g\u00f6sterebilir. E\u015fik a\u015f\u0131m\u0131n\u0131 da g\u00f6sterebilir. A\u00e7\u0131klama anahtar\u0131 ve sonu\u00e7 kriterleri olmadan hangisi oldu\u011funu bilemezsiniz.<\/p>\n<p>Eksenleri, test ko\u015fullar\u0131n\u0131 ve filtre kimli\u011fini tarama grafi\u011fiyle birlikte tutun. Grafi\u011fi yorumlamadan \u00f6nce \u00f6l\u00e7\u00fcm\u00fc ve kabul \u00f6l\u00e7\u00fctlerini a\u00e7\u0131klayan raporu isteyin.<\/p>\n<p>Test tarihini, rapor kimli\u011fini, ekipman kimli\u011fini ve sonucu onaylayan ki\u015fiyi veya sistemi de aray\u0131n. Baz\u0131 izlenebilirlik ve kalibrasyon bilgileri tek sayfal\u0131k sertifikaya bas\u0131lmak yerine destekleyici laboratuvar kay\u0131tlar\u0131nda tutulabilir. Gerekti\u011finde destekleyici kayd\u0131 isteyin. Her \u015feyin sertifikan\u0131n \u00f6n sayfas\u0131na s\u0131\u011fmas\u0131 gerekmez.<\/p>\n<h2>Fabrika sertifikas\u0131 montaj sonras\u0131 durumu do\u011frulamaz<\/h2>\n<p>Fabrika raporu teslimat ve montaj boyunca filtreyle birlikte tutulmal\u0131d\u0131r. Filtrenin monte edildi\u011fi yeri kaydedin ve raporu montaj sonras\u0131 test kayd\u0131yla ili\u015fkilendirin.<\/p>\n<p>Belgelerin hi\u00e7biri di\u011ferinin yerini almaz. IEST\u2019nin g\u00fcncel ka\u00e7ak testi uygulamas\u0131; \u00fcretim s\u0131ras\u0131nda, montajdan \u00f6nce ve montajdan sonra testleri, tam da bunlar farkl\u0131 a\u015famalar oldu\u011fu i\u00e7in kapsar. <a href=\"https:\/\/www.iest.org\/Standards-RPs\/Recommended-Practices\/IEST-RP-CC034\" target=\"_blank\" rel=\"noopener noreferrer\">IEST-RP-CC034.5<\/a><\/p>\n<h2>S\u0131k sorulan sorular<\/h2>\n<h3>Sertifikadaki %99,995 mutlaka \u00f6l\u00e7\u00fclm\u00fc\u015f bir sonu\u00e7 mudur?<\/h3>\n<p>Hay\u0131r. H14 i\u00e7in hedef veya alt s\u0131n\u0131r olabilir. \u00d6l\u00e7\u00fclen sonu\u00e7 ile kabul s\u0131n\u0131r\u0131n\u0131 ayr\u0131 ayr\u0131 tan\u0131mlayan alanlar\u0131 bulun. Yaln\u0131zca s\u0131n\u0131f alt s\u0131n\u0131r\u0131n\u0131 tekrarlayan sertifika, bu rakamla tek ba\u015f\u0131na filtrenin ger\u00e7ek \u00f6l\u00e7\u00fcm\u00fcn\u00fc g\u00f6stermez.<\/p>\n<h3>\u201cKa\u00e7aks\u0131z\u201d demek filtreden s\u0131f\u0131r par\u00e7ac\u0131k ge\u00e7mesi mi demektir?<\/h3>\n<p>Hay\u0131r. Filtrenin belirtilen testin ka\u00e7ak kriterini kar\u015f\u0131lad\u0131\u011f\u0131 anlam\u0131na gelir. HEPA s\u0131n\u0131flar\u0131 s\u0131f\u0131rdan b\u00fcy\u00fck penetrasyona izin verir. Sonucu hangi y\u00f6ntem ve kabul s\u0131n\u0131r\u0131n\u0131n destekledi\u011fini sorun; \u201cka\u00e7aks\u0131z\u201d ifadesi mutlak s\u0131f\u0131r penetrasyon iddias\u0131 de\u011fildir.<\/p>\n<h3>Sahadaki fotometre y\u00fczdesini fabrikadaki MPPS y\u00fczdesiyle do\u011frudan kar\u015f\u0131la\u015ft\u0131rabilir miyim?<\/h3>\n<p>Hay\u0131r. Aerosol, cihaz tepkisi, numune alma ve kabul esas\u0131 farkl\u0131 olabilir. Her sonucu kendi y\u00f6ntemi ve s\u0131n\u0131rlar\u0131yla kullan\u0131n. Saha sonucu, sertifikada yazan fabrika veriminden \u00e7\u0131kar\u0131larak yorumlanamaz.<\/p>\n<h3>E12 filtrede neden ayn\u0131 tarama sertifikas\u0131 bulunmaz?<\/h3>\n<p>E12, s\u0131n\u0131fland\u0131rmas\u0131nda HEPA yerel tarama gereklili\u011fi kullan\u0131lmayan EPA grubuna aittir. Her filtre s\u0131n\u0131f\u0131n\u0131n ayn\u0131 rapor bi\u00e7imiyle gelmesi gerekti\u011fini varsaymak yerine, o s\u0131n\u0131f i\u00e7in ge\u00e7erli s\u0131n\u0131fland\u0131rma ve performans belgelerini isteyin.<\/p>\n<h2>Kaynaklar<\/h2>\n<ul>\n<li><a href=\"https:\/\/landingpage.bsigroup.com\/LandingPage\/Undated?UPI=000000000001386856\" target=\"_blank\" rel=\"noopener noreferrer\">EN 1822-1:2019, b\u00f6l\u00fcmler 7.4\u20137.5<\/a><\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/84367.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 29463-1:2024<\/a><\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/51838.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 29463-4:2011<\/a><\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/77740.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 29463-5:2022<\/a><\/li>\n<li><a href=\"https:\/\/www.vdma.eu\/documents\/34570\/14642203\/VDMA%2BLuftfilterinformation%2B%282019-10%29%2BFilterklassen%2Bder%2BRaumluft-%2Bund%2BEntstaubungstechnik%2Bim%2B%C3%9Cberblick%2B%284%29.pdf\/caae6004-906e-16fa-e059-a2dce0bb97b1?t=1618313384618\" target=\"_blank\" rel=\"noopener noreferrer\">VDMA filtre s\u0131n\u0131fland\u0131rma tablosu<\/a><\/li>\n<li><a href=\"https:\/\/www.iest.org\/Standards-RPs\/Recommended-Practices\/IEST-RP-CC034\" target=\"_blank\" rel=\"noopener noreferrer\">IEST-RP-CC034.5<\/a><\/li>\n<li><a href=\"https:\/\/www.ulpatek.com\/wp-content\/uploads\/2026\/10\/HEPA-Ceiling-Filter-Aluminium-Frame-TR.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Tavan filtresi teknik f\u00f6y\u00fc<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>HEPA sertifikas\u0131nda seri numaras\u0131n\u0131, hava debisini, MPPS esas\u0131n\u0131, toplam verimi ve yerel ka\u00e7ak sonucunu kontrol edin; temsili bir H14 \u00f6rne\u011fini inceleyin.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[445],"tags":[],"class_list":["post-15088","post","type-post","status-publish","format-standard","hentry","category-guide-standards-tr"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15088","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/comments?post=15088"}],"version-history":[{"count":2,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15088\/revisions"}],"predecessor-version":[{"id":17754,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15088\/revisions\/17754"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/media?parent=15088"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/categories?post=15088"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/tags?post=15088"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}