{"id":15086,"date":"2026-10-04T10:00:00","date_gmt":"2026-10-04T07:00:00","guid":{"rendered":"https:\/\/www.ulpatek.com\/?p=15086"},"modified":"2026-10-01T14:05:48","modified_gmt":"2026-10-01T11:05:48","slug":"eurovent-4-23-hala-eski-oda-sup-tablosunu-mu-kullaniyorsunuz","status":"publish","type":"post","link":"https:\/\/www.ulpatek.com\/tr\/filtre-teknolojisi\/eurovent-4-23-hala-eski-oda-sup-tablosunu-mu-kullaniyorsunuz\/","title":{"rendered":"Eurovent 4\/23: H\u00e2l\u00e2 eski ODA\/SUP tablosunu mu kullan\u0131yorsunuz?"},"content":{"rendered":"<p>Eurovent 4\/23-2022, d\u0131\u015f hava kalitesi ve gerekli \u00fcfleme havas\u0131 kalitesi ile havaland\u0131rma sisteminin ihtiya\u00e7 duydu\u011fu filtrasyon verimi aras\u0131nda ba\u011flant\u0131 kurar. D\u00f6rd\u00fcnc\u00fc bask\u0131, WHO\u2019nun 2021 hava kalitesi rehberini kullan\u0131r. Bu nedenle \u00f6nceki WHO de\u011ferlerine dayanan bir ODA\/SUP tablosu, farkl\u0131 filtre se\u00e7imine yol a\u00e7abilir. Bir \u015fartnameyi kopyalamadan \u00f6nce bask\u0131s\u0131n\u0131 kontrol edin. <a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/2022-01-18-eurovent-publishes-updated-version-4-23-recommendation.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent\u2019in yay\u0131n duyurusu<\/a><\/p>\n<p>\u00d6nce binan\u0131n ihtiyac\u0131n\u0131 ve hava emi\u015f noktas\u0131ndaki kirleticileri belirleyin. Ard\u0131ndan se\u00e7ilen filtrasyon kademelerinin birlikte sa\u011flayaca\u011f\u0131 performans\u0131 kontrol edin. F7, F9 veya ePM1 %80 gibi bir s\u0131n\u0131f etiketi, bu de\u011ferlendirmelerin tamam\u0131 i\u00e7in yeterli de\u011fildir.<\/p>\n<h2>Referans de\u011ferler neden \u00f6nemlidir?<\/h2>\n<p>WHO\u2019nun 2021 rehberinde y\u0131ll\u0131k ortalama k\u0131lavuz de\u011ferler PM2.5 i\u00e7in 5 \u00b5g\/m\u00b3, PM10 i\u00e7in 15 \u00b5g\/m\u00b3 olarak belirlenmi\u015ftir. Bunlar sa\u011fl\u0131k temelli tavsiyelerdir; her yerde ge\u00e7erli yasal s\u0131n\u0131rlar de\u011fildir. Y\u0131ll\u0131k ortalamalar, canl\u0131 hava kalitesi ekran\u0131nda g\u00f6r\u00fclen k\u0131sa s\u00fcreli \u00f6l\u00e7\u00fcmlerden de farkl\u0131 bir amaca hizmet eder. <a href=\"https:\/\/www.who.int\/news-room\/questions-and-answers\/item\/who-global-air-quality-guidelines\" target=\"_blank\" rel=\"noopener noreferrer\">WHO hava kalitesi rehberi<\/a>, <a href=\"https:\/\/www.ncbi.nlm.nih.gov\/books\/NBK574582\/table\/fm-ch1.tab1\/\" target=\"_blank\" rel=\"noopener noreferrer\">WHO k\u0131lavuz de\u011ferleri<\/a><\/p>\n<p>Filtre listesini haz\u0131rlarken ilgili d\u00f6nemi kapsayan veriler kullan\u0131n. D\u0131\u015f hava kategorisi, havan\u0131n temiz oldu\u011fu tek bir sabah\u0131n \u00f6l\u00e7\u00fcm\u00fcyle belirlenemez; tozlu bir \u00f6\u011fleden sonran\u0131n \u00f6l\u00e7\u00fcm\u00fc de b\u00fct\u00fcn y\u0131l\u0131 temsil etmez. Veri kayna\u011f\u0131n\u0131, izleme konumunu ve ortalama al\u0131nan d\u00f6nemi tasar\u0131m hesab\u0131yla birlikte saklay\u0131n. Hesab\u0131 daha sonra inceleyecek ki\u015finin bu ba\u011flama ihtiyac\u0131 vard\u0131r.<\/p>\n<p>Eurovent 4\/23 bir se\u00e7im tavsiyesidir. Dayand\u0131\u011f\u0131 ISO 16890 serisi ise genel havaland\u0131rma filtrelerini partik\u00fcl madde verimine g\u00f6re s\u0131n\u0131fland\u0131r\u0131r. \u0130ki belgenin g\u00f6revleri farkl\u0131d\u0131r: biri filtre performans\u0131n\u0131 tan\u0131mlar; di\u011feri tasar\u0131mc\u0131lar\u0131n se\u00e7im yaparken bu performans\u0131 kullanmas\u0131na yard\u0131mc\u0131 olur. <a href=\"https:\/\/www.iso.org\/standard\/57864.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 16890-1:2016 kapsam\u0131<\/a>, <a href=\"https:\/\/www.eurovent.eu\/publications\/eurovent-4-23-2022-selection-of-en-iso-16890-rated-air-filter-classes-fourth-edition-english\/\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/23 yay\u0131n sayfas\u0131<\/a><\/p>\n<h2>2022 ODA\/SUP de\u011ferleri<\/h2>\n<p>A\u015fa\u011f\u0131daki tablo, Eurovent\u2019in d\u00f6rd\u00fcnc\u00fc bask\u0131s\u0131ndaki d\u0131\u015f hava kategorilerini, \u00fcfleme havas\u0131 konsantrasyon hedeflerini ve en d\u00fc\u015f\u00fck verimleri bir araya getirir. Konsantrasyonlar \u00b5g\/m\u00b3 cinsinden y\u0131ll\u0131k ortalamalard\u0131r; her de\u011fer \u00e7ifti PM2.5 \/ PM10 s\u0131ras\u0131ndad\u0131r.<\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>D\u0131\u015f hava kategorisi<\/th>\n<th>D\u0131\u015f hava konsantrasyon e\u015fikleri<\/th>\n<th>SUP1: \u22641,25 \/ \u22643,75<\/th>\n<th>SUP2: \u22642,5 \/ \u22647,5<\/th>\n<th>SUP3: \u22643,75 \/ \u226411,25<\/th>\n<th>SUP4: \u22645 \/ \u226415<\/th>\n<th>SUP5: \u22647,5 \/ \u226422,5<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>ODA1<\/td>\n<td>\u22645 \/ \u226415<\/td>\n<td>ePM1 %70<\/td>\n<td>ePM1 %50<\/td>\n<td>ePM2.5 %50<\/td>\n<td>ePM10 %50<\/td>\n<td>ePM10 %50<\/td>\n<\/tr>\n<tr>\n<td>ODA2<\/td>\n<td>ODA1\u2019in \u00fczerinde; 7,5 \/ 22,5\u2019e kadar<\/td>\n<td>ePM1 %80<\/td>\n<td>ePM1 %70<\/td>\n<td>ePM2.5 %70<\/td>\n<td>ePM10 %80<\/td>\n<td>ePM10 %50<\/td>\n<\/tr>\n<tr>\n<td>ODA3<\/td>\n<td>&gt;7,5 \/ &gt;22,5<\/td>\n<td>ePM1 %90<\/td>\n<td>ePM1 %80<\/td>\n<td>ePM2.5 %80<\/td>\n<td>ePM10 %90<\/td>\n<td>ePM10 %80<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Verimler, tek bir filtre veya birden fazla kademenin birle\u015fik performans\u0131 i\u00e7in ge\u00e7erlidir. Tavsiye ayr\u0131ca SUP1 ve SUP2 i\u00e7in en az ISO ePM1 %50, SUP3 i\u00e7in ise ISO ePM2.5 %50 son kademe belirtir. Bu dipnotlar tablodan ayr\u0131lmamal\u0131d\u0131r. <a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/eurovent-rec-4-23-selection-of-en-iso-16890-rated-air-filter-classes-fourth-edition-2022-en-web_0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/23-2022, Tablolar 1\u20133<\/a><\/p>\n<p>PM2.5 ve PM10 farkl\u0131 d\u0131\u015f hava kategorilerine i\u015faret ediyorsa tasar\u0131mc\u0131dan bu fark\u0131 de\u011ferlendirmesini ve se\u00e7im esas\u0131n\u0131 kaydetmesini isteyin. \u0130ki kirleticinin ortalamas\u0131n\u0131 al\u0131p tek de\u011fer h\u00e2line getirmeyin.<\/p>\n<h2>Tablodaki de\u011fer, sistemin sa\u011flamas\u0131 gereken verimdir<\/h2>\n<p>Tasar\u0131mc\u0131n\u0131n ODA2\u2019yi belirledi\u011fi ve SUP2\u2019yi se\u00e7ti\u011fi bir \u00f6rnek proje d\u00fc\u015f\u00fcn\u00fcn. Tabloya g\u00f6re gereken verim ePM1 %70\u2019tir. Uygun filtre d\u00fczenlerini kar\u015f\u0131la\u015ft\u0131rmak i\u00e7in bu gereklili\u011fi kullan\u0131n. \u201c%70\u201d de\u011ferinin hangi partik\u00fcl fraksiyonuna ait oldu\u011fu belirtilmelidir.<\/p>\n<p>Bu y\u00fczdenin hangi partik\u00fcl fraksiyonuna ait oldu\u011funu sorun. ePM10 de\u011feri, ePM1 de\u011ferinin yerine kullan\u0131lamaz. \u00dcr\u00fcn\u00fcn hangi hava debisinde de\u011ferlendirildi\u011fini ve \u00f6nerilen \u00f6l\u00e7\u00fclerin mevcut filtre kutusuyla e\u015fle\u015fip e\u015fle\u015fmedi\u011fini sorun. Ard\u0131ndan ama\u00e7lanan \u00e7al\u0131\u015fma noktas\u0131ndaki bas\u0131n\u00e7 kayb\u0131n\u0131 kontrol edin.<\/p>\n<p>Birden fazla uygulanabilir d\u00fczen olabilir. Uygun tek filtre ile do\u011fru se\u00e7ilmi\u015f iki kademeli d\u00fczenin sat\u0131n alma maliyetleri, alan ihtiya\u00e7lar\u0131 ve bak\u0131m i\u015fleri farkl\u0131 olabilir. Her iki \u00f6neri ayn\u0131 performans gereklili\u011fini kar\u015f\u0131lay\u0131p ayn\u0131 i\u015fletme varsay\u0131mlar\u0131n\u0131 kulland\u0131\u011f\u0131nda kar\u015f\u0131la\u015ft\u0131rma yararl\u0131 h\u00e2le gelir.<\/p>\n<p>Bu varsay\u0131mlar\u0131 se\u00e7ilen h\u00fccrenin yan\u0131na yaz\u0131n. B\u00f6ylece ekip, sonraki \u00fcr\u00fcn de\u011fi\u015fikliklerini ayn\u0131 \u00e7al\u0131\u015fma ko\u015fullar\u0131na g\u00f6re kontrol edebilir.<\/p>\n<h2>\u0130ki kademenin y\u00fczdelerini toplamay\u0131n<\/h2>\n<p>Basitle\u015ftirilmi\u015f hesap, her kademenin ge\u00e7irdi\u011fi oran\u0131 kullan\u0131r. Varsay\u0131lan ko\u015fullarda iki kademenin her biri ayn\u0131 giri\u015f par\u00e7ac\u0131k fraksiyonunun %50\u2019sini gideriyorsa ilk kademe %50\u2019yi b\u0131rak\u0131r; ikinci kademe bu kalan\u0131n yar\u0131s\u0131n\u0131 giderir. Birle\u015fik giderim %100 de\u011fil, %75 olur.<\/p>\n<p>Kesir bi\u00e7iminde:<\/p>\n<p><strong>Birle\u015fik verim = 1 \u2212 (1 \u2212 verim\u2081) \u00d7 (1 \u2212 verim\u2082)<\/strong><\/p>\n<p>Geni\u015f kapsaml\u0131 ePM de\u011ferleriyle yap\u0131lan hesaplar\u0131 tahmin olarak de\u011ferlendirin. \u0130lk filtre, ikinciye ula\u015fan par\u00e7ac\u0131k boyutu da\u011f\u0131l\u0131m\u0131n\u0131 de\u011fi\u015ftirir. Eurovent, basitle\u015ftirilmi\u015f m\u00fchendislik tahminini temel performans verileriyle yap\u0131lan daha ayr\u0131nt\u0131l\u0131 hesaptan ay\u0131r\u0131r. Bu nedenle s\u0131n\u0131rda kalan bir sonu\u00e7, yuvarlanarak uygun say\u0131lmamal\u0131; tedarik\u00e7inin verileriyle netle\u015ftirilmelidir. <a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/eurovent-rec-4-23-selection-of-en-iso-16890-rated-air-filter-classes-fourth-edition-2022-en-web_0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/23-2022, b\u00f6l\u00fcm 5<\/a><\/p>\n<p>Tedarik\u00e7iye birle\u015fik verimin nas\u0131l hesapland\u0131\u011f\u0131n\u0131 sorun. \u0130ki katalog etiketi, \u00f6nerilen filtre dizisinin nas\u0131l de\u011ferlendirildi\u011fini tek ba\u015f\u0131na g\u00f6stermez.<\/p>\n<h2>Asgari se\u00e7im, odada \u00f6l\u00e7\u00fclecek konsantrasyonu garanti etmez<\/h2>\n<p>ODA3\u2019\u00fcn bir \u00fcst konsantrasyon s\u0131n\u0131r\u0131 yoktur. Yo\u011fun kirli b\u00f6lgelerde iki tesis ayn\u0131 kategoride yer al\u0131rken hava emi\u015flerine \u00e7ok farkl\u0131 par\u00e7ac\u0131k y\u00fckleri gelebilir.<\/p>\n<p>Basit bir \u00f6rnek olarak, giri\u015fteki 50 \u00b5g\/m\u00b3 PM2.5 konsantrasyonunda ger\u00e7ek bir %80 azalma, geriye 10 \u00b5g\/m\u00b3 b\u0131rak\u0131r. Bu bir aritmetik hesapt\u0131r; ISO ePM1 etiketinden t\u00fcretilmi\u015f tahmin de\u011fildir. Geni\u015f bir kategori ve matristeki asgari de\u011ferin, \u00e7\u0131k\u0131\u015f taraf\u0131nda belirli bir konsantrasyonu neden tek ba\u015f\u0131na garanti edemedi\u011fini g\u00f6sterir.<\/p>\n<p>Mek\u00e2n\u0131n kullan\u0131m\u0131ndan kaynaklanan ko\u015fullar da de\u011ferlendirilmelidir: Kap\u0131lardan ne kadar hava giriyor, i\u00e7eride hangi par\u00e7ac\u0131klar olu\u015fuyor ve odaya ne kadar etkili havaland\u0131rma ula\u015f\u0131yor? Tasar\u0131m\u0131 desteklemek i\u00e7in matrisi kullan\u0131n; ard\u0131ndan ger\u00e7ek konsantrasyon hedefini projenin ko\u015fullar\u0131na g\u00f6re kontrol edin. \u015eartnamede bu iki karar\u0131 ayr\u0131 ayr\u0131 belirtin.<\/p>\n<h2>Filtrasyon gereklili\u011fini belirledikten sonra i\u015fletme maliyetini kar\u015f\u0131la\u015ft\u0131r\u0131n<\/h2>\n<p>Gerekli performans netle\u015ftikten sonra bas\u0131n\u00e7 kayb\u0131, \u00fcr\u00fcnleri ay\u0131rt etmek i\u00e7in yararl\u0131 bir \u00f6l\u00e7\u00fct olur. Filtreleri ayn\u0131 hava debisinde ve \u00f6l\u00e7\u00fclerde; \u00e7al\u0131\u015fma saatleri ve de\u011fi\u015fimle ilgili uyumlu varsay\u0131mlarla kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/p>\n<p>Eurovent 4\/24-2023, Update 1, ger\u00e7ek \u00e7al\u0131\u015fma ko\u015fullar\u0131ndaki tahminleri ele al\u0131r. Ayr\u0131ca daha d\u00fc\u015f\u00fck filtre direncinin neden her sistemde kendili\u011finden ayn\u0131 enerji tasarrufunu sa\u011flamad\u0131\u011f\u0131n\u0131 a\u00e7\u0131klar: fan kontrol\u00fc ve bunun sonucunda olu\u015fan hava debisi \u00f6nemlidir. Ayarlanabilir fan h\u0131z\u0131na sahip sabit debili bir sistem, sabit h\u0131zda b\u0131rak\u0131lan bir fandan farkl\u0131 davran\u0131r. <a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/publications-files\/eurovent-rec-4-24-energy-consumption-evaluation-2023-en-update-1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/24, Update 1<\/a><\/p>\n<p>Yararl\u0131 bir teklif i\u00e7in \u015fu bilgileri ekleyin:<\/p>\n<ol>\n<li>D\u0131\u015f hava verileri ve se\u00e7ilen ODA\/SUP kategorileri.<\/li>\n<li>Gerekli partik\u00fcl fraksiyonu, verim ve son kademenin asgari seviyesi.<\/li>\n<li>Hava debisi, filtre adedi, ger\u00e7ek \u00f6l\u00e7\u00fcler ve kullan\u0131labilir derinlik.<\/li>\n<li>Ba\u015flang\u0131\u00e7 bas\u0131n\u00e7 kayb\u0131 s\u0131n\u0131r\u0131 ve \u00f6nerilen de\u011fi\u015fim kriteri.<\/li>\n<li>Enerji kar\u015f\u0131la\u015ft\u0131rmas\u0131nda kullan\u0131lan fan kontrol\u00fc, \u00e7al\u0131\u015fma saatleri ve varsay\u0131mlar.<\/li>\n<\/ol>\n<h2>Se\u00e7im s\u0131ras\u0131nda g\u00fcndeme gelen sorular<\/h2>\n<h3>Eski F7 veya F9 tan\u0131m\u0131n\u0131 kullanmay\u0131 s\u00fcrd\u00fcrebilir miyim?<\/h3>\n<p>Mevcut kurulumun referans\u0131 olarak koruyun; ard\u0131ndan ger\u00e7ekten gerekli olan ISO 16890 performans\u0131n\u0131 belirtin. Eski bir etiket tek ba\u015f\u0131na \u00f6nerilen yedek filtrenin \u00f6l\u00e7\u00fclm\u00fc\u015f ePM de\u011ferlerini g\u00f6stermez.<\/p>\n<h3>SUP1 se\u00e7mek, kendili\u011finden H14 gerekti\u011fi anlam\u0131na m\u0131 gelir?<\/h3>\n<p>Bu matristen do\u011frudan H14 karar\u0131 \u00e7\u0131kmaz. Tablo genel havaland\u0131rma se\u00e7imini ele al\u0131r; HEPA filtrasyonu gerektiren bir temizoda veya s\u00fcre\u00e7 i\u00e7in uygulamaya \u00f6zg\u00fc gereklilikler ayr\u0131ca belirlenmelidir.<\/p>\n<h3>Tablo her ihaleye kopyalanmal\u0131 m\u0131?<\/h3>\n<p>Ge\u00e7erli referans\u0131 ve se\u00e7ilen \u00e7al\u0131\u015fma ko\u015fullar\u0131n\u0131 ekleyin. Se\u00e7ilen kategori, hava debisi ve kabul gereklilikleri olmadan verilen tam tablo, tedarik\u00e7iyi projenin ger\u00e7ek gerekliliklerini tahmin etmek zorunda b\u0131rak\u0131r.<\/p>\n<h2>Kaynaklar<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/eurovent-rec-4-23-selection-of-en-iso-16890-rated-air-filter-classes-fourth-edition-2022-en-web_0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/23-2022, d\u00f6rd\u00fcnc\u00fc bask\u0131<\/a><\/li>\n<li><a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/2022-01-18-eurovent-publishes-updated-version-4-23-recommendation.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 2022 g\u00fcncelleme duyurusu<\/a><\/li>\n<li><a href=\"https:\/\/www.who.int\/news-room\/questions-and-answers\/item\/who-global-air-quality-guidelines\" target=\"_blank\" rel=\"noopener noreferrer\">WHO K\u00fcresel Hava Kalitesi Rehberi<\/a><\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/57864.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 16890-1:2016<\/a><\/li>\n<li><a href=\"https:\/\/www.eurovent.eu\/wp-content\/uploads\/publications-files\/eurovent-rec-4-24-energy-consumption-evaluation-2023-en-update-1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Eurovent 4\/24-2023, Update 1<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Eurovent 4\/23-2022\u2019nin ODA\/SUP de\u011ferlerini do\u011fru kullan\u0131n. Kademelerin birle\u015fik verimini, son kademe gereklili\u011fini ve se\u00e7imin varsay\u0131mlar\u0131n\u0131 kontrol edin.<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[433],"tags":[],"class_list":["post-15086","post","type-post","status-publish","format-standard","hentry","category-guide-selection-tr"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15086","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/comments?post=15086"}],"version-history":[{"count":1,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15086\/revisions"}],"predecessor-version":[{"id":15678,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15086\/revisions\/15678"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/media?parent=15086"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/categories?post=15086"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/tags?post=15086"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}