{"id":15084,"date":"2026-10-01T14:04:45","date_gmt":"2026-10-01T11:04:45","guid":{"rendered":"https:\/\/www.ulpatek.com\/?p=15084"},"modified":"2026-10-01T14:47:37","modified_gmt":"2026-10-01T11:47:37","slug":"h13-mu-h14-mu-uygulamaya-gore-hepa-filtre-secim-rehberi","status":"publish","type":"post","link":"https:\/\/www.ulpatek.com\/tr\/filtre-teknolojisi\/h13-mu-h14-mu-uygulamaya-gore-hepa-filtre-secim-rehberi\/","title":{"rendered":"H13 m\u00fc H14 m\u00fc? Uygulamaya g\u00f6re HEPA filtre se\u00e7im rehberi"},"content":{"rendered":"<p>H13 filtrenin <strong>MPPS\u2019de en az %99,95 toplam verime<\/strong> ula\u015fmas\u0131 gerekir; H14 bu alt s\u0131n\u0131r\u0131 <strong>%99,995<\/strong> d\u00fczeyine y\u00fckseltir. H14 i\u00e7in izin verilen en y\u00fcksek toplam penetrasyon, H13 s\u0131n\u0131r\u0131n\u0131n onda biridir. \u0130kisi aras\u0131nda se\u00e7im yapmak i\u00e7in yine de uygulamay\u0131, hava debisini, montaj\u0131 ve kabul gerekliliklerini kontrol etmeniz gerekir. <a href=\"https:\/\/landingpage.bsigroup.com\/LandingPage\/Undated?UPI=000000000001386856\" target=\"_blank\" rel=\"noopener noreferrer\">EN 1822-1:2019, s\u0131n\u0131fland\u0131rma tablosu<\/a><\/p>\n<p>Mevcut \u015fartname H14 gerektiriyorsa H14 tedarik edilmelidir. Yeni bir tasar\u0131mda ise se\u00e7im yapmadan \u00f6nce \u015fu sorular\u0131n yan\u0131tlanmas\u0131 gerekir. Filtreye hangi kirleticiler ula\u015f\u0131yor? Mek\u00e2n\u0131n i\u00e7inde neler olu\u015fuyor? S\u00fcre\u00e7 a\u00e7\u0131s\u0131ndan hangi par\u00e7ac\u0131klar \u00f6nemli? Filtreler y\u00fcklendik\u00e7e sistem gerekli hava debisini koruyabiliyor mu?<\/p>\n<h2>Fark, penetrasyondad\u0131r<\/h2>\n<p>Verim de\u011ferlerinde art arda bir\u00e7ok dokuz bulundu\u011funda penetrasyonu, yani filtreden ge\u00e7en par\u00e7ac\u0131k oran\u0131n\u0131 kar\u015f\u0131la\u015ft\u0131rmak daha kolayd\u0131r.<\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>EN 1822 s\u0131n\u0131f\u0131<\/th>\n<th align=\"right\">MPPS\u2019de en d\u00fc\u015f\u00fck toplam verim<\/th>\n<th align=\"right\">En y\u00fcksek toplam penetrasyon<\/th>\n<th align=\"right\">En y\u00fcksek yerel penetrasyon, referans MPPS taramas\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>H13<\/td>\n<td align=\"right\">%99,95<\/td>\n<td align=\"right\">%0,05<\/td>\n<td align=\"right\">%0,25<\/td>\n<\/tr>\n<tr>\n<td>H14<\/td>\n<td align=\"right\">%99,995<\/td>\n<td align=\"right\">%0,005<\/td>\n<td align=\"right\">%0,025<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Yerel s\u0131n\u0131rlar, tan\u0131mlanm\u0131\u015f filtre eleman\u0131 testiyle ilgilidir. <strong>Monte edilmi\u015f filtrelerin fotometreyle test edilmesi i\u00e7in evrensel kabul s\u0131n\u0131rlar\u0131 de\u011fildir.<\/strong> S\u0131n\u0131f de\u011ferleri <a href=\"https:\/\/www.vdma.eu\/documents\/34570\/14642203\/VDMA%2BLuftfilterinformation%2B%282019-10%29%2BFilterklassen%2Bder%2BRaumluft-%2Bund%2BEntstaubungstechnik%2Bim%2B%C3%9Cberblick%2B%284%29.pdf\/caae6004-906e-16fa-e059-a2dce0bb97b1?t=1618313384618\" target=\"_blank\" rel=\"noopener noreferrer\">VDMA filtre s\u0131n\u0131flar\u0131na genel bak\u0131\u015f belgesinde<\/a> de g\u00f6sterilir.<\/p>\n<p>Test edilen boyutta 100.000 par\u00e7ac\u0131k i\u00e7eren a\u00e7\u0131klay\u0131c\u0131 bir aerosol uygulamas\u0131nda, s\u0131n\u0131f s\u0131n\u0131r\u0131ndaki toplam penetrasyon H13 i\u00e7in 50, H14 i\u00e7in be\u015f par\u00e7ac\u0131\u011f\u0131n ge\u00e7mesine kar\u015f\u0131l\u0131k gelir. Ger\u00e7ekte s\u0131n\u0131fa uygun filtreler, s\u0131n\u0131flar\u0131n\u0131n alt s\u0131n\u0131r\u0131ndan daha iyi performans g\u00f6sterebilir. Bunlar s\u0131n\u0131rlar\u0131n aritmetik kar\u015f\u0131l\u0131klar\u0131d\u0131r; bir temizodada beklenen par\u00e7ac\u0131k say\u0131lar\u0131 de\u011fildir.<\/p>\n<figure class=\"inline-figure\">\n<div class=\"penetration-row\"><b>H13<\/b><\/p>\n<div class=\"dot-grid\" aria-hidden=\"true\"><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><\/div>\n<div class=\"penetration-number\"><strong>50<\/strong><small>ge\u00e7en par\u00e7ac\u0131k<\/small><\/div>\n<\/div>\n<div class=\"penetration-row\"><b>H14<\/b><\/p>\n<div class=\"dot-grid h14\" aria-hidden=\"true\"><i><\/i><i><\/i><i><\/i><i><\/i><i><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><i class=\"empty\"><\/i><\/div>\n<div class=\"penetration-number\"><strong>5<\/strong><small>ge\u00e7en par\u00e7ac\u0131k<\/small><\/div>\n<\/div><figcaption>H13 ve H14 s\u0131n\u0131f s\u0131n\u0131rlar\u0131n\u0131n kar\u015f\u0131la\u015ft\u0131rmas\u0131: Test edilen boyuttaki 100.000 par\u00e7ac\u0131k i\u00e7in izin verilen en y\u00fcksek ge\u00e7i\u015f say\u0131s\u0131 H13\u2019te 50, H14\u2019te 5\u2019tir. Bu hesap temizodadaki par\u00e7ac\u0131k say\u0131s\u0131n\u0131 g\u00f6stermez.<\/figcaption><\/figure>\n<p><strong>MPPS<\/strong>, en y\u00fcksek penetrasyonun g\u00f6r\u00fcld\u00fc\u011f\u00fc par\u00e7ac\u0131k boyutu demektir: filtrenin test ko\u015fullar\u0131nda en d\u00fc\u015f\u00fck verime sahip oldu\u011fu boyuttur. Her zaman 0,3 \u00b5m anlam\u0131na gelmez. ISO 29463-5:2022, MPPS\u2019de verimi ele al\u0131r ve MPPS de\u011feri 0,1 \u00b5m\u2019nin alt\u0131nda kalan filtreler i\u00e7in h\u00fck\u00fcmler i\u00e7erir. <a href=\"https:\/\/www.iso.org\/standard\/77740.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 29463-5:2022<\/a><\/p>\n<p>Bu nedenle \u201c0,3 \u00b5m\u2019de %99,97\u201d ifadesi, herhangi bir a\u00e7\u0131klama yap\u0131lmadan \u201cH13\u201d veya \u201cH14\u201d olarak yeniden yaz\u0131lmamal\u0131d\u0131r. Farkl\u0131 bir par\u00e7ac\u0131k boyutuna veya test y\u00f6ntemine ba\u011fl\u0131 \u015fartname, o gereklili\u011fe uygun kan\u0131t gerektirir.<\/p>\n<figure class=\"real-product-photo\" data-ulpatek-real-photo=\"6916\"><img data-src=\"https:\/\/www.ulpatek.com\/wp-content\/uploads\/2024\/01\/HEPA-Ceiling-Filter-Aluminium-Frame-1024x1024.png\" width=\"1024\" height=\"1024\" alt=\"Al\u00fcminyum \u00e7er\u00e7eveli, pileli medyal\u0131 ve \u00e7evresinde siyah conta bulunan Ulpatek HEPA tavan filtresi.\" decoding=\"async\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/1024;\"><figcaption><span>Al\u00fcminyum \u00e7er\u00e7eveli ve \u00e7evresel contal\u0131 Ulpatek HEPA tavan filtresi.<\/span><a href=\"https:\/\/www.ulpatek.com\/tr\/urunler\/mutlak-filtrasyon\/tavan-tipi-hepa-filtre\/\">\u00dcr\u00fcn ayr\u0131nt\u0131lar\u0131n\u0131 g\u00f6r\u00fcn \u2192<\/a><\/figcaption><\/figure>\n<h2>ISO temizoda s\u0131n\u0131f\u0131, filtre s\u0131n\u0131f\u0131 de\u011fildir<\/h2>\n<p>ISO 14644-1:2015, hava temizli\u011fini \u00f6l\u00e7\u00fclen havadaki par\u00e7ac\u0131k konsantrasyonuna g\u00f6re s\u0131n\u0131fland\u0131r\u0131r. H13 ve H14 ise filtre performans\u0131n\u0131 s\u0131n\u0131fland\u0131r\u0131r. ISO 14644-1\u2019de bunlar\u0131 birbirine do\u011frudan d\u00f6n\u00fc\u015ft\u00fcren bir tablo yoktur. <a href=\"https:\/\/www.iso.org\/standard\/53394.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 14644-1:2015<\/a><\/p>\n<p>\u00d6rne\u011fin bir odaya \u00e7ok temiz \u00fcfleme havas\u0131 verilirken s\u00fcre\u00e7, insanlar, ekipman veya malzeme transferleri nedeniyle odada yine de a\u015f\u0131r\u0131 miktarda par\u00e7ac\u0131k bulunabilir. H13 yerine H14 kullanmak, kar\u015f\u0131la\u015ft\u0131r\u0131labilir ko\u015fullarda filtreden ge\u00e7en par\u00e7ac\u0131k oran\u0131n\u0131 azalt\u0131r. \u00dcr\u00fcn\u00fcn yan\u0131ndaki kontrols\u00fcz bir kayna\u011f\u0131 ortadan kald\u0131rmaz.<\/p>\n<p>H14\u2019\u00fcn temizodada neden kendili\u011finden daha h\u0131zl\u0131 toparlanma sa\u011flamad\u0131\u011f\u0131n\u0131 da bu a\u00e7\u0131klar. Toparlanma; hava debisine, havan\u0131n kontaminasyonu ne kadar etkili uzakla\u015ft\u0131rd\u0131\u011f\u0131na veya seyreltti\u011fine, \u00fcfleme havas\u0131n\u0131n temizli\u011fine ve devam eden kaynaklara ba\u011fl\u0131d\u0131r. De\u011fi\u015fim, sa\u011flanan hava debisini azalt\u0131yorsa daha y\u00fcksek filtre s\u0131n\u0131f\u0131na bakarak odan\u0131n daha h\u0131zl\u0131 toparlanaca\u011f\u0131 s\u00f6ylenemez.<\/p>\n<p>Tasar\u0131m ve kalifikasyon s\u0131ras\u0131nda hem filtre performans\u0131n\u0131 hem oda performans\u0131n\u0131 kontrol edin.<\/p>\n<h2>EU GMP Annex 1 ger\u00e7ekte ne ister?<\/h2>\n<p>2022 Annex 1, tesisler i\u00e7in uygun filtrasyon verimi gerektirir ve ilgili kalifikasyon kontrolleri aras\u0131nda monte edilmi\u015f filtrelerin ka\u00e7ak\/b\u00fct\u00fcnl\u00fck testine yer verir. Kontaminasyon kontrol stratejisini ve farkl\u0131 dereceler i\u00e7in gerekli ko\u015fullar\u0131 tan\u0131mlar. H13 ile H14 aras\u0131nda se\u00e7im yapt\u0131ran bir tablo i\u00e7ermez. <a href=\"https:\/\/health.ec.europa.eu\/system\/files\/2022-08\/20220825_gmp-an1_en_0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Avrupa Komisyonu, EU GMP Annex 1, b\u00f6l\u00fcmler 2.3, 4.1 ve 4.25<\/a><\/p>\n<p>Yeni bir kritik aseptik alan\u0131n \u00fcfleme havas\u0131 \u015fartnamesi i\u00e7in <strong>H14, ilk de\u011ferlendirmeye al\u0131nmas\u0131 mant\u0131kl\u0131 bir adayd\u0131r<\/strong>; s\u00fcre\u00e7teki hava debisi, ekipman konfig\u00fcrasyonu ve kalifikasyon gereklilikleriyle birlikte ele al\u0131nmal\u0131d\u0131r. Bu bir m\u00fchendislik ba\u015flang\u0131\u00e7 noktas\u0131d\u0131r; Annex 1\u2019in H14\u2019\u00fc a\u00e7\u0131k\u00e7a zorunlu tuttu\u011fu iddias\u0131 de\u011fildir.<\/p>\n<p>Birisi H14 esas al\u0131narak haz\u0131rlanm\u0131\u015f tasar\u0131m i\u00e7in H13 \u00f6neriyorsa, yan\u0131t \u201cikisi de HEPA\u201d olamaz. De\u011fi\u015fen \u015fartnamenin neden h\u00e2l\u00e2 uygun oldu\u011funu g\u00f6stermesi ve projenin de\u011fi\u015fiklik kontrol gerekliliklerini izlemesi gerekir. Filtre s\u0131n\u0131f\u0131, \u00fczerinde anla\u015f\u0131lm\u0131\u015f tasar\u0131m\u0131n bir par\u00e7as\u0131d\u0131r.<\/p>\n<h2>Kullanabilece\u011finiz bir karar tablosu<\/h2>\n<p>Tabloyu tasar\u0131m incelemesini ba\u015flatmak i\u00e7in kullan\u0131n. Proje \u015fartnamesinin veya ulusal gerekliliklerin yerini almaz; oda s\u0131n\u0131f\u0131n\u0131 filtre s\u0131n\u0131f\u0131na do\u011frudan d\u00f6n\u00fc\u015ft\u00fcrmez.<\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>Uygulama<\/th>\n<th>Ba\u015flang\u0131\u00e7 noktas\u0131<\/th>\n<th>Son se\u00e7imi belirleyenler<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Mevcut, kalifiye edilmi\u015f kurulum<\/td>\n<td>Onayl\u0131 s\u0131n\u0131f\u0131 koruyun<\/td>\n<td>S\u0131n\u0131f, bas\u0131n\u00e7 kayb\u0131 veya s\u0131zd\u0131rmazl\u0131k de\u011fi\u015fikli\u011fi mevcut tasar\u0131ma ve kabul gerekliliklerine g\u00f6re de\u011ferlendirilmelidir<\/td>\n<\/tr>\n<tr>\n<td>Grade A \u00e7al\u0131\u015fma b\u00f6lgesi dahil yeni kritik aseptik b\u00f6lge<\/td>\n<td>\u00d6nce terminal H14 filtrasyonu de\u011ferlendirin<\/td>\n<td>S\u00fcre\u00e7 korumas\u0131, bariyer tasar\u0131m\u0131, kritik y\u00fczeylerin do\u011frudan temiz hava ile korunmas\u0131, montaj sonras\u0131 b\u00fct\u00fcnl\u00fck ve kalifikasyon sonu\u00e7lar\u0131<\/td>\n<\/tr>\n<tr>\n<td>Aseptik s\u00fcrecin Grade B arka plan alan\u0131<\/td>\n<td>H14\u2019\u00fc de\u011ferlendirin; t\u00fcm oda tasar\u0131m\u0131n\u0131 kontrol edin<\/td>\n<td>\u0130\u015fletme s\u0131ras\u0131nda olu\u015fan kontaminasyon kaynaklar\u0131, hava debisi ve arka plan alan\u0131 i\u00e7in belirlenmi\u015f ko\u015fullar<\/td>\n<\/tr>\n<tr>\n<td>Grade C\/D veya ISO 7\/8 \u00fcretim odas\u0131<\/td>\n<td>Ger\u00e7ek HEPA ihtiyac\u0131n\u0131 de\u011ferlendirin; terminal HEPA belirtilmi\u015fse H13 aday olabilir<\/td>\n<td>Par\u00e7ac\u0131k ve mikrobiyal riskler, \u00f6nceki kademelerdeki filtrasyon, s\u00fcre\u00e7 emisyonlar\u0131 ve onayl\u0131 tasar\u0131m esas\u0131<\/td>\n<\/tr>\n<tr>\n<td>Optik ve elektronik dahil ila\u00e7 d\u0131\u015f\u0131ndaki temiz \u00fcretim uygulamalar\u0131<\/td>\n<td>Kritik par\u00e7ac\u0131k boyutlar\u0131na g\u00f6re H13, H14 veya ULPA\u2019y\u0131 kar\u015f\u0131la\u015ft\u0131r\u0131n<\/td>\n<td>Yaln\u0131zca odan\u0131n ISO numaras\u0131 de\u011fil, \u00fcr\u00fcn\u00fcn bulundu\u011fu noktada s\u00fcrece \u00f6zg\u00fc temizlik<\/td>\n<\/tr>\n<tr>\n<td>Hastane ameliyathanesi<\/td>\n<td>\u0130lgili sa\u011fl\u0131k tesisi havaland\u0131rma \u015fartnamesini ve oda t\u00fcr\u00fcn\u00fc esas al\u0131n<\/td>\n<td>Yerel standart, cerrahi ortam ve t\u00fcm havaland\u0131rma sistemi; \u201chastane = H14\u201d bir \u015fartname de\u011fildir<\/td>\n<\/tr>\n<tr>\n<td>Koruyucu ortam veya hava yoluyla bula\u015fan enfeksiyon izolasyon odas\u0131<\/td>\n<td>Gereklili\u011fin \u00fcfleme, resirk\u00fclasyon veya egzoz havas\u0131yla m\u0131 ilgili oldu\u011funu belirleyin<\/td>\n<td>Hasta korumas\u0131 veya kirleticiyi hapsetme amac\u0131, bas\u0131n\u00e7 y\u00f6n\u00fc, tahliye d\u00fczeni ve ilgili sa\u011fl\u0131k tesisi gereklilikleri<\/td>\n<\/tr>\n<tr>\n<td>Genel ticari HVAC<\/td>\n<td>HEPA\u2019n\u0131n gerekli olup olmad\u0131\u011f\u0131n\u0131 kontrol edin<\/td>\n<td>Uygun tasar\u0131m, bir ISO 16890 filtre dizisi olabilir; hava debisini ve par\u00e7ac\u0131k giderme hedefini do\u011frulay\u0131n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Hastane uygulamalar\u0131nda se\u00e7im, yaln\u0131zca filtre s\u0131n\u0131f\u0131na bak\u0131larak yap\u0131lamaz. CDC rehberi, hassas hastalar\u0131 koruyan koruyucu ortamlar\u0131, bula\u015f\u0131c\u0131 havay\u0131 hapseden hava yoluyla bula\u015fan enfeksiyon izolasyon odalar\u0131ndan ay\u0131r\u0131r. Rehberde do\u011frudan egzoz ile resirk\u00fclasyon i\u00e7in de farkl\u0131 gereklilikler tan\u0131mlan\u0131r. \u00d6nce odan\u0131n hastay\u0131 m\u0131 korudu\u011funu yoksa kirli havay\u0131 m\u0131 hapsetti\u011fini ve egzozun nereye verildi\u011fini kontrol edin. Daha y\u00fcksek filtre s\u0131n\u0131f\u0131 tek ba\u015f\u0131na uygunsuz bir egzoz tahliye yerini kabul edilebilir h\u00e2le getirmez. <a href=\"https:\/\/www.cdc.gov\/infection-control\/hcp\/environmental-control\/air.html\" target=\"_blank\" rel=\"noopener noreferrer\">CDC \u00e7evresel enfeksiyon kontrol\u00fc rehberi: hava<\/a><\/p>\n<p>Oda tipi hava temizleyicide cihaz\u0131n tamam\u0131n\u0131 da de\u011ferlendirin. NHS England\u2019\u0131n HEPA cihazlar\u0131 rehberi, filtre s\u0131n\u0131fland\u0131rmas\u0131n\u0131n yan\u0131nda yerinde performans\u0131, hava debisini ve yerle\u015fimi de ele al\u0131r. \u00c7ok d\u00fc\u015f\u00fck debide \u00e7al\u0131\u015fan y\u00fcksek s\u0131n\u0131fl\u0131 bir filtre, tek ba\u015f\u0131na eksiksiz bir hava temizleme \u00e7\u00f6z\u00fcm\u00fc de\u011fildir. <a href=\"https:\/\/www.england.nhs.uk\/long-read\/application-of-hepa-filter-devices-for-air-cleaning-in-healthcare-spaces-guidance-and-standards\/\" target=\"_blank\" rel=\"noopener noreferrer\">NHS England NETB 2023\/01A<\/a><\/p>\n<h2>H14\u2019\u00fcn bas\u0131n\u00e7 kayb\u0131 her zaman daha m\u0131 y\u00fcksektir?<\/h2>\n<p>S\u0131n\u0131f, belirli bir bas\u0131n\u00e7 kayb\u0131 \u015fart ko\u015fmaz. Ger\u00e7ek de\u011feri medya \u00f6zellikleri, medya alan\u0131, pile geometrisi, \u00e7er\u00e7eve derinli\u011fi ve hava debisi belirler.<\/p>\n<p>Kar\u015f\u0131la\u015ft\u0131r\u0131labilir bir \u00fcr\u00fcn ailesi i\u00e7inde H14 daha y\u00fcksek ba\u015flang\u0131\u00e7 direncine sahip olabilir. Sekt\u00f6r geneline ait bir y\u00fczde yerine, Ulpatek\u2019ten somut bir \u00f6rnek:<\/p>\n<div class=\"table-scroll\" role=\"region\" aria-label=\"Teknik kar\u015f\u0131la\u015ft\u0131rma tablosu\" tabindex=\"0\">\n<table>\n<thead>\n<tr>\n<th>Katalog modeli<\/th>\n<th>\u00d6l\u00e7\u00fcler<\/th>\n<th align=\"right\">Nominal hava debisi<\/th>\n<th align=\"right\">Yay\u0131mlanan ba\u015flang\u0131\u00e7 bas\u0131n\u00e7 kayb\u0131<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>HC-H13-A-3-610-610-100-FB-P<\/td>\n<td>610 \u00d7 610 \u00d7 100 mm<\/td>\n<td align=\"right\">600 m\u00b3\/h<\/td>\n<td align=\"right\">75 Pa<\/td>\n<\/tr>\n<tr>\n<td>HC-H14-A-3-610-610-100-FB-P<\/td>\n<td>610 \u00d7 610 \u00d7 100 mm<\/td>\n<td align=\"right\">600 m\u00b3\/h<\/td>\n<td align=\"right\">90 Pa<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>2024 katalo\u011fu, her ikisi i\u00e7in 75 mm pile ve \u00b1%10 fark bas\u0131nc\u0131 tolerans\u0131 belirtir. Bu modeller i\u00e7in bu hava debisinde listelenen fark <strong>15 Pa, yani %20<\/strong> d\u00fczeyindedir. Bu fark, t\u00fcm H14 filtrelerin direncinin %20 daha y\u00fcksek olaca\u011f\u0131 anlam\u0131na gelmez. <a href=\"https:\/\/www.ulpatek.com\/wp-content\/uploads\/2024\/07\/Product-Technical-Catalogue-24_07_24.pdf#page=145\" target=\"_blank\" rel=\"noopener noreferrer\">Ulpatek \u00dcr\u00fcn Teknik Katalo\u011fu, s. 145<\/a><\/p>\n<p>Ger\u00e7ek tasar\u0131m debinizdeki bas\u0131n\u00e7 kayb\u0131 e\u011frisini isteyin. Farkl\u0131 nominal debilerdeki iki katalog de\u011ferini kar\u015f\u0131la\u015ft\u0131rmak adil bir kar\u015f\u0131la\u015ft\u0131rma de\u011fildir. Filtre y\u00fcklendik\u00e7e fan\u0131n sa\u011flayabilece\u011fi bas\u0131nc\u0131 da kontrol edin; ba\u015flang\u0131\u00e7 direnci yaln\u0131zca ilk durumdur.<\/p>\n<h2>Fabrika test belgeleri ve montaj sonras\u0131 kabul ayr\u0131 de\u011ferlendirilir<\/h2>\n<p>Yaln\u0131zca \u201cHEPA, tek tek test edilmi\u015f\u201d yaz\u0131p b\u00fct\u00fcn tedarik\u00e7ilerin ayn\u0131 y\u00f6ntemi anlad\u0131\u011f\u0131n\u0131 varsaymay\u0131n.<\/p>\n<p>S\u0131n\u0131fland\u0131rma standard\u0131n\u0131 ve gerekli ka\u00e7ak testi y\u00f6ntemini belirtin. Referans y\u00f6ntem, par\u00e7ac\u0131k say\u0131m\u0131yla tarama yapar; izin verilen alternatifler s\u0131n\u0131fa ve ilgili standarda ba\u011fl\u0131d\u0131r. EN 1822 ve ISO 29463 birbiriyle ili\u015fkilidir, ancak izin verdikleri test y\u00f6ntemleri ayn\u0131 de\u011fildir. Projeniz her filtre i\u00e7in ayr\u0131 MPPS tarama raporu gerektiriyorsa bunu a\u00e7\u0131k\u00e7a yaz\u0131n. <a href=\"https:\/\/landingpage.bsigroup.com\/LandingPage\/Undated?UPI=000000000001386856\" target=\"_blank\" rel=\"noopener noreferrer\">EN 1822-1:2019, b\u00f6l\u00fcm 7.4<\/a>, <a href=\"https:\/\/www.iso.org\/standard\/51838.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 29463-4 test y\u00f6ntemi kapsam\u0131<\/a><\/p>\n<p>Ard\u0131ndan montaj sonras\u0131 testi ayr\u0131 olarak tan\u0131mlay\u0131n. H13\u2019ten H14\u2019e ge\u00e7mek tek ba\u015f\u0131na yeni bir fotometre, tarama h\u0131z\u0131 veya evrensel bir saha ka\u00e7ak s\u0131n\u0131r\u0131 belirlemez. Bunlar, \u00fczerinde anla\u015f\u0131lm\u0131\u015f test prosed\u00fcr\u00fcnde belirlenir.<\/p>\n<h2>Eksik bilgileri teklif talebine ekleyin<\/h2>\n<p>Kullan\u0131labilir bir teklif i\u00e7in \u015funlar\u0131 g\u00f6nderin:<\/p>\n<ol>\n<li>Projeye \u00f6zg\u00fc test gereklilikleriyle birlikte istenen s\u0131n\u0131f ve standart.<\/li>\n<li>Filtre ba\u015f\u0131na hava debisi ve bu debide kabul edilebilir en y\u00fcksek ba\u015flang\u0131\u00e7 bas\u0131n\u00e7 kayb\u0131.<\/li>\n<li>Ger\u00e7ek \u00e7er\u00e7eve \u00f6l\u00e7\u00fcleri ve kullan\u0131labilir derinlik.<\/li>\n<li>Conta veya jel d\u00fczeni, s\u0131zd\u0131rmazl\u0131k taraf\u0131 ve filtre kutusu \u00e7izimi.<\/li>\n<li>\u00c7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131 ve varsa temizlik veya dekontaminasyon maruziyeti.<\/li>\n<li>Gerekli filtre bazl\u0131 belgeler ve montaj sonras\u0131 kabul prosed\u00fcr\u00fc.<\/li>\n<\/ol>\n<p>\u0130lgili \u00fcr\u00fcn bilgisi: <a href=\"https:\/\/www.ulpatek.com\/wp-content\/uploads\/2024\/01\/HEPA-Ceiling-Filter-Aluminium-Frame.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">HEPA tavan filtreleri<\/a>.<\/p>\n<h2>S\u0131k sorulan sorular<\/h2>\n<h3>ISO Class 5, H14 filtre gerektirir mi?<\/h3>\n<p>ISO 14644-1, zorunlu H13 veya H14 filtreleri de\u011fil, par\u00e7ac\u0131k konsantrasyonu s\u0131n\u0131flar\u0131n\u0131 tan\u0131mlar. Tasar\u0131m, kullan\u0131m amac\u0131 i\u00e7in gereken temizli\u011fi sa\u011flamal\u0131d\u0131r. H14 uygun bir se\u00e7im olabilir, ancak filtrenin \u00fczerindeki etiket odan\u0131n ISO Class 5\u2019e uygun oldu\u011funu g\u00f6stermez.<\/p>\n<h3>H14 filtre, H13\u2019ten on kat daha m\u0131 iyidir?<\/h3>\n<p>MPPS\u2019de izin verilen en y\u00fcksek toplam penetrasyonu on kat daha d\u00fc\u015f\u00fckt\u00fcr: %0,05 yerine %0,005. Bu kar\u015f\u0131la\u015ft\u0131rma s\u0131n\u0131f s\u0131n\u0131rlar\u0131 i\u00e7in ge\u00e7erlidir. Oda havas\u0131n\u0131n on kat temiz, kullan\u0131m \u00f6mr\u00fcn\u00fcn on kat uzun veya enfeksiyon riskinin on kat d\u00fc\u015f\u00fck oldu\u011fu anlam\u0131na gelmez.<\/p>\n<h3>Enerji t\u00fcketimini azaltmak i\u00e7in H14 yerine H13 kullanabilir miyim?<\/h3>\n<p>Yaln\u0131zca de\u011fi\u015fiklik onayl\u0131 tasar\u0131ma g\u00f6re de\u011ferlendirildikten sonra. Kontaminasyon kontrol gerekliliklerini kontrol edin ve \u00f6l\u00e7\u00fclm\u00fc\u015f diren\u00e7leri ayn\u0131 hava debisinde kar\u015f\u0131la\u015ft\u0131r\u0131n. Filtre kutusu izin veriyorsa daha geni\u015f medya alan\u0131 veya daha fazla derinlik sunan bir H14 yap\u0131s\u0131n\u0131 da de\u011ferlendirin.<\/p>\n<h3>H14 etiketi, saha b\u00fct\u00fcnl\u00fck testinin ba\u015far\u0131yla ge\u00e7ilece\u011fini garanti eder mi?<\/h3>\n<p>Hay\u0131r. Montaj sonras\u0131 sonu\u00e7; ta\u015f\u0131ma ve elle\u00e7lemeye, filtre ile filtre kutusu aras\u0131ndaki s\u0131zd\u0131rmazl\u0131\u011fa, filtre kutusuna ve test y\u00f6ntemine de ba\u011fl\u0131d\u0131r. Sipari\u015ften \u00f6nce fabrika test belgelerini isteyin ve montaj sonras\u0131 kabul gerekliliklerini belirtin.<\/p>\n<h2>Kaynaklar<\/h2>\n<ul>\n<li><a href=\"https:\/\/landingpage.bsigroup.com\/LandingPage\/Undated?UPI=000000000001386856\" target=\"_blank\" rel=\"noopener noreferrer\">EN 1822-1:2019, s\u0131n\u0131fland\u0131rma tablosu<\/a><\/li>\n<li><a href=\"https:\/\/www.vdma.eu\/documents\/34570\/14642203\/VDMA%2BLuftfilterinformation%2B%282019-10%29%2BFilterklassen%2Bder%2BRaumluft-%2Bund%2BEntstaubungstechnik%2Bim%2B%C3%9Cberblick%2B%284%29.pdf\/caae6004-906e-16fa-e059-a2dce0bb97b1?t=1618313384618\" target=\"_blank\" rel=\"noopener noreferrer\">VDMA filtre s\u0131n\u0131flar\u0131na genel bak\u0131\u015f<\/a><\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/77740.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 29463-5:2022<\/a><\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/53394.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 14644-1:2015<\/a><\/li>\n<li><a href=\"https:\/\/health.ec.europa.eu\/system\/files\/2022-08\/20220825_gmp-an1_en_0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Avrupa Komisyonu, EU GMP Annex 1, b\u00f6l\u00fcmler 2.3, 4.1 ve 4.25<\/a><\/li>\n<li><a href=\"https:\/\/www.cdc.gov\/infection-control\/hcp\/environmental-control\/air.html\" target=\"_blank\" rel=\"noopener noreferrer\">CDC \u00e7evresel enfeksiyon kontrol\u00fc rehberi: hava<\/a><\/li>\n<li><a href=\"https:\/\/www.england.nhs.uk\/long-read\/application-of-hepa-filter-devices-for-air-cleaning-in-healthcare-spaces-guidance-and-standards\/\" target=\"_blank\" rel=\"noopener noreferrer\">NHS England NETB 2023\/01A<\/a><\/li>\n<li><a href=\"https:\/\/www.ulpatek.com\/wp-content\/uploads\/2024\/07\/Product-Technical-Catalogue-24_07_24.pdf#page=145\" target=\"_blank\" rel=\"noopener noreferrer\">Ulpatek \u00dcr\u00fcn Teknik Katalo\u011fu, s. 145<\/a><\/li>\n<li><a href=\"https:\/\/www.iso.org\/standard\/51838.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 29463-4 test y\u00f6ntemi kapsam\u0131<\/a><\/li>\n<li><a href=\"https:\/\/www.ulpatek.com\/wp-content\/uploads\/2024\/01\/HEPA-Ceiling-Filter-Aluminium-Frame.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">HEPA tavan filtreleri<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>H13 ve H14\u2019\u00fc MPPS\u2019deki penetrasyonla kar\u015f\u0131la\u015ft\u0131r\u0131n. Se\u00e7imden \u00f6nce temizoda ve hastane gerekliliklerini, bas\u0131n\u00e7 kayb\u0131n\u0131 ve test belgelerini kontrol edin. <a class=\"read-more-link\" href=\"https:\/\/www.ulpatek.com\/tr\/filtre-teknolojisi\/h13-mu-h14-mu-uygulamaya-gore-hepa-filtre-secim-rehberi\/\">Read more<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[439],"tags":[],"class_list":["post-15084","post","type-post","status-publish","format-standard","hentry","category-guide-hepa-tr"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15084","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/comments?post=15084"}],"version-history":[{"count":1,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15084\/revisions"}],"predecessor-version":[{"id":15666,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/posts\/15084\/revisions\/15666"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/media?parent=15084"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/categories?post=15084"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/tags?post=15084"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}