{"id":4808,"date":"2019-09-20T10:43:50","date_gmt":"2019-09-20T07:43:50","guid":{"rendered":"https:\/\/www.ulpatek.com\/?page_id=4808"},"modified":"2026-10-02T07:50:20","modified_gmt":"2026-10-02T04:50:20","slug":"hijyenik-alanlarda-tavan-tipi-hepa-filtre-uygulamalari","status":"publish","type":"page","link":"https:\/\/www.ulpatek.com\/tr\/filtre-teknolojisi\/hijyenik-alanlarda-tavan-tipi-hepa-filtre-uygulamalari\/","title":{"rendered":"H\u0130JYEN\u0130K ALANLARDA TAVAN T\u0130P\u0130 HEPA F\u0130LTRE UYGULAMALARI"},"content":{"rendered":"<div class=\"wpb-content-wrapper\" id=\"wpb-content-root\"><p>[vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text]<\/p>\n<p>&nbsp;<\/p>\n<p>Hijyenik klima sistemlerin tasar\u0131m\u0131nda dikkate al\u0131nmas\u0131 gereken parametrelerin ba\u015f\u0131nda ortamda bulunabilecek maksimum partik\u00fcl konsantrasyonu ve \u00e7ap\u0131 gelir. Bunun d\u0131\u015f\u0131nda s\u0131cakl\u0131k, nem, bas\u0131n\u00e7, ses \u015fiddeti, titre\u015fim, statik elektrik gibi parametrelerin de kontrol alt\u0131na al\u0131nmas\u0131 gerekir.<\/p>\n<p>Konumuzun ba\u015fl\u0131\u011f\u0131nda da anla\u015f\u0131laca\u011f\u0131 gibi hijyenik klima sistemlerinde istenilen maksimum partik\u00fcl konsantrasyonu ve \u00e7ap\u0131n\u0131 yakalamak i\u00e7in kullan\u0131lan HEPA filtre tavan uygulamalar\u0131n\u0131 ele alaca\u011f\u0131z. Hijyenik klima sistemlerinde kullan\u0131lan HEPA filtrelerin ila\u00e7, g\u0131da, kimya, kozmetik, elektronik otomotiv (cam), hastane (Ameliyathane\/Yo\u011fun Bak\u0131m \u00dcniteleri) ve laboratuvarlarda ki kullan\u0131mlar\u0131 her ge\u00e7en g\u00fcn artmaktad\u0131r. HEPA (High Efficiency Particulate Air) filtreler ile ilgili Avrupa Birli\u011fi \u00fclkelerinin ba\u011fl\u0131 oldu\u011fu CEN (European Committee for Standardization) taraf\u0131ndan yay\u0131nlanan EN 1822 standartlar\u0131 ile A.B.D. men\u015feli IEST (Institute of Environmental Sciences and Technology) taraf\u0131ndan yay\u0131nlanan standartlar bulunmaktad\u0131r. Bu standartlar kullan\u0131c\u0131dan \u00e7ok, filtre \u00fcreticilerini ilgilendiren standartlard\u0131r.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_single_image image=&#8221;4887&#8243; img_size=&#8221;medium&#8221; alignment=&#8221;center&#8221; onclick=&#8221;custom_link&#8221; css_animation=&#8221;bounceInDown&#8221;][vc_empty_space height=&#8221;15px&#8221;][vc_btn title=&#8221;Bilgilendirme bro\u015f\u00fcr\u00fcn\u00fc indirmek i\u00e7in t\u0131klay\u0131n\u0131z.&#8221; color=&#8221;info&#8221; align=&#8221;center&#8221; i_icon_fontawesome=&#8221;fa fa-file-pdf-o&#8221; css_animation=&#8221;bounceInDown&#8221; add_icon=&#8221;true&#8221; link=&#8221;url:https%3A%2F%2Fwww.ulpatek.com%2Ftr%2Fhijyenik-alanlarda-tavan-tipi-hepa-filtre-uygulamalari-2%2F|||&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]Kullan\u0131mdaki mevcut standartlar aras\u0131ndaki e\u015fde\u011ferlik eksikli\u011fi hem \u00fcretici hem de t\u00fcketici i\u00e7in zorluklar yaratmaktad\u0131r. ISO 29463 (Havadaki Partik\u00fcllerin Giderilmesi i\u00e7in Y\u00fcksek Verimli Filtreler ve Filtre Medyas\u0131; ilk bask\u0131 2011, ISO 29463-1\u2019in g\u00fcncel bask\u0131s\u0131 2024), EN 1822 temel al\u0131narak haz\u0131rlanm\u0131\u015f uluslararas\u0131 standartt\u0131r ve d\u00fcnya \u00e7ap\u0131nda kullan\u0131lan ba\u015fl\u0131ca standartlar\u0131n filtre s\u0131n\u0131fland\u0131rmas\u0131n\u0131 kapsar. Avrupa\u2019da s\u0131n\u0131fland\u0131rma EN 1822-1:2019\u2019a g\u00f6re yap\u0131l\u0131r.<\/p>\n<p>Hava ile ta\u015f\u0131nan partik\u00fcl konsantrasyonunun kontrol edildi\u011fi, oda i\u00e7erisine partik\u00fcl giri\u015fini, partik\u00fcl olu\u015fumunu ve partik\u00fcllerin oda i\u00e7erisinde kalmas\u0131n\u0131 minimize edecek \u015fekilde in\u015fa edilmi\u015f, ayr\u0131ca gerekliliklere g\u00f6re s\u0131cakl\u0131k, bas\u0131n\u00e7 ve nem gibi parametrelerin kontrol edildi\u011fi \u00f6zel alanlara temizoda (cleanroom) denir. Temizodalar ISO 14644-1:2015 standard\u0131na g\u00f6re a\u015fa\u011f\u0131daki gibi s\u0131n\u0131fland\u0131r\u0131r;[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<table style=\"height: 1102px;\" width=\"1107\">\n<tbody>\n<tr>\n<td rowspan=\"2\" width=\"86\">\n<p style=\"text-align: center;\"><strong>I<\/strong><strong style=\"font-family: inherit; font-size: inherit;\">SO S\u0131n\u0131f Numaras\u0131 (N)<\/strong><\/p>\n<\/td>\n<td colspan=\"6\" width=\"518\"><strong>De\u011ferlendirmeye al\u0131nan boyutlardan daha b\u00fcy\u00fck ve e\u015fit partik\u00fcller i\u00e7in en y\u00fcksek konsantrasyon d\u00fczeyleri (partik\u00fcl\/m\u00b3) (a)<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"86\">\n<p style=\"text-align: center;\"><strong>0.1 \u00b5m<\/strong><\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"86\"><strong>0.2 \u00b5m<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"86\"><strong>0.3 \u00b5m<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"86\"><strong>0.5 \u00b5m<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"86\"><strong>1.0 \u00b5m<\/strong><\/td>\n<td width=\"86\">\n<p style=\"text-align: center;\"><strong>5.0 \u00b5m<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">\n<p style=\"text-align: center;\"><strong>1<\/strong><\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"86\">10<\/td>\n<td style=\"text-align: center;\" width=\"86\">d<\/td>\n<td style=\"text-align: center;\" width=\"86\">d<\/td>\n<td style=\"text-align: center;\" width=\"86\">d<\/td>\n<td style=\"text-align: center;\" width=\"86\">d<\/td>\n<td style=\"text-align: center;\" width=\"86\">e<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">\n<p style=\"text-align: center;\"><strong>2<\/strong><\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"86\">100<\/td>\n<td style=\"text-align: center;\" width=\"86\">24<sup>(b)<\/sup><\/td>\n<td style=\"text-align: center;\" width=\"86\">10<sup>(b)<\/sup><\/td>\n<td style=\"text-align: center;\" width=\"86\">d<\/td>\n<td style=\"text-align: center;\" width=\"86\">d<\/td>\n<td style=\"text-align: center;\" width=\"86\">e<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"86\"><strong>3<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"86\">1.000<\/td>\n<td style=\"text-align: center;\" width=\"86\">237<\/td>\n<td style=\"text-align: center;\" width=\"86\">102<\/td>\n<td style=\"text-align: center;\" width=\"86\">35<sup>(b)<\/sup><\/td>\n<td style=\"text-align: center;\" width=\"86\">d<\/td>\n<td width=\"86\">\n<p style=\"text-align: center;\">e<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">\n<p style=\"text-align: center;\"><strong>4<\/strong><\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"86\">10.000<\/td>\n<td style=\"text-align: center;\" width=\"86\">2.370<\/td>\n<td style=\"text-align: center;\" width=\"86\">1.020<\/td>\n<td style=\"text-align: center;\" width=\"86\">352<\/td>\n<td style=\"text-align: center;\" width=\"86\">83<sup>(b)<\/sup><\/td>\n<td style=\"text-align: center;\" width=\"86\">e<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">\n<p style=\"text-align: center;\"><strong>5<\/strong><\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"86\">100.000<\/td>\n<td style=\"text-align: center;\" width=\"86\">23.700<\/td>\n<td style=\"text-align: center;\" width=\"86\">10.200<\/td>\n<td style=\"text-align: center;\" width=\"86\">3.520<\/td>\n<td style=\"text-align: center;\" width=\"86\">832<\/td>\n<td width=\"86\">\n<p style=\"text-align: center;\">d,e,f<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"86\"><strong>6<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"86\">1.000.000<\/td>\n<td style=\"text-align: center;\" width=\"86\">237.000<\/td>\n<td style=\"text-align: center;\" width=\"86\">102.000<\/td>\n<td style=\"text-align: center;\" width=\"86\">35.200<\/td>\n<td style=\"text-align: center;\" width=\"86\">8.320<\/td>\n<td width=\"86\">\n<p style=\"text-align: center;\">293<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">\n<p style=\"text-align: center;\"><strong>7<\/strong><\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"86\">c<\/td>\n<td style=\"text-align: center;\" width=\"86\">c<\/td>\n<td style=\"text-align: center;\" width=\"86\">c<\/td>\n<td style=\"text-align: center;\" width=\"86\">352.000<\/td>\n<td style=\"text-align: center;\" width=\"86\">83.200<\/td>\n<td width=\"86\">\n<p style=\"text-align: center;\">2.930<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"86\">\n<p style=\"text-align: center;\"><strong>8<\/strong><\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"86\">c<\/td>\n<td style=\"text-align: center;\" width=\"86\">c<\/td>\n<td style=\"text-align: center;\" width=\"86\">c<\/td>\n<td style=\"text-align: center;\" width=\"86\">3.520.000<\/td>\n<td style=\"text-align: center;\" width=\"86\">832.000<\/td>\n<td width=\"86\">\n<p style=\"text-align: center;\">29.300<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"86\"><strong>9<\/strong><\/td>\n<td style=\"text-align: center;\" width=\"86\">c<\/td>\n<td style=\"text-align: center;\" width=\"86\">c<\/td>\n<td style=\"text-align: center;\" width=\"86\">c<\/td>\n<td style=\"text-align: center;\" width=\"86\">35.200.000<\/td>\n<td style=\"text-align: center;\" width=\"86\">8.320.000<\/td>\n<td width=\"86\">\n<p style=\"text-align: center;\">293.000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"7\" width=\"604\"><strong>Notlar:<\/strong><\/p>\n<p><strong>a)\u00a0\u00a0\u00a0\u00a0\u00a0 <\/strong>Tablodaki t\u00fcm de\u011ferler k\u00fcm\u00fclatiftir (ilgili partik\u00fcl boyutu ve bundan b\u00fcy\u00fck partik\u00fcllerin toplam de\u011ferini ifade eder).<\/p>\n<p><strong>b)\u00a0\u00a0\u00a0\u00a0\u00a0 <\/strong>Bu konsantrasyon de\u011ferleri y\u00fcksek numune hacimleri gerektirebilir. Ek D\u2019de tan\u0131mlanan ard\u0131\u015f\u0131k numune alma prosed\u00fcr\u00fc uygulanabilir.<\/p>\n<p><strong>c)\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <\/strong>Bu partik\u00fcl seviyesinde belirtilen temizlik s\u0131n\u0131flar\u0131 i\u00e7in (y\u00fcksek konsantrasyon nedeniyle) s\u0131n\u0131fland\u0131rma tan\u0131mlanmam\u0131\u015ft\u0131r.<\/p>\n<p><strong>d)\u00a0\u00a0\u00a0\u00a0\u00a0 <\/strong>Bu seviyede partik\u00fcl say\u0131m\u0131 olmas\u0131 durumunda s\u0131n\u0131fland\u0131rma ge\u00e7ersizdir.<\/p>\n<p><strong>e)\u00a0\u00a0\u00a0\u00a0\u00a0 <\/strong>1.0 \u00b5m\u2019den b\u00fcy\u00fck partik\u00fcllerin numune hatt\u0131nda tutulmas\u0131 riski sebebiyle tan\u0131mlama yap\u0131lmam\u0131\u015ft\u0131r.<\/p>\n<p><strong>f)\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 <\/strong>5.0 \u00b5m e\u015fit ve b\u00fcy\u00fck partik\u00fcl tan\u0131m\u0131 i\u00e7in gerekli ise M tan\u0131mlay\u0131c\u0131s\u0131 kullan\u0131lmal\u0131d\u0131r.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]Temizodada istenilen s\u0131n\u0131fa ula\u015f\u0131lmas\u0131 i\u00e7in yukar\u0131daki parametreler dikkate al\u0131narak hijyenik klima sistemi d\u00fczg\u00fcn tasarlanmal\u0131d\u0131r. Ayr\u0131ca in\u015fai olarak odan\u0131n haz\u0131rlanmas\u0131, temizoda i\u00e7indeki kontaminasyon (kirlilik, bula\u015fma) kaynaklar\u0131n\u0131n s\u0131n\u0131rland\u0131r\u0131lmas\u0131 ve bu ama\u00e7la odalardaki hava ak\u0131\u015f d\u00fczenin se\u00e7ilmesi, \u00e7al\u0131\u015fanlar\u0131n\/\u00fcr\u00fcn\u00fcn\/\u00e7evrenin korunmas\u0131, personelin kullanaca\u011f\u0131 giysiler, malzeme, ekipman se\u00e7imi vb. kriterler de \u00f6nemlidir.<\/p>\n<p>Klasik bir temizodada HEPA\/ULPA filtreler genellikle tavanda ve sisteminin son \u00fcr\u00fcn\u00fc olarak yer al\u0131r. Bu \u015fekilde filtreden ge\u00e7en hava do\u011frudan temizodaya ula\u015fm\u0131\u015f olur. Bu sebeple HEPA filtreler hem y\u00fczeyde hem de oturduklar\u0131 kanallarda s\u0131zd\u0131rmaz bir yap\u0131da olmal\u0131d\u0131r. Klima santralinin son filtre kademesinde HEPA kullan\u0131p temizoda tasar\u0131m\u0131nda da di\u011fer kriterlere uyuldu\u011funda ISO 8 ve ISO 9 alanlar, tavanda HEPA uygulamas\u0131 olmadan da ula\u015f\u0131labilecek seviyelerdir.\u00a0 Ancak bir\u00e7ok i\u015fletme risk almamak ve ilerde daha temizoda s\u0131n\u0131f\u0131na ihtiya\u00e7 duyabilirim diye \u00f6zellikle ISO 8 alanlarda da tavanda HEPA uygulamas\u0131 yapmaktad\u0131r.<\/p>\n<p>Son y\u0131llarda GMP, FED 209 ve \u00f6zellikle ISO 14644-1 standartlar\u0131n\u0131 dikkate alan i\u015fletmeler kendi gereksinimlerini de belirleyerek tavanda HEPA filtreleri \u00e7ok yayg\u0131n olarak kullanmaktad\u0131r. NAFA (National Air Filtration Association) 2014 y\u0131l\u0131nda yay\u0131nlad\u0131\u011f\u0131 \u201cGuide to Air Filtration \/ Chapter 9\u201d bask\u0131s\u0131nda tavanda HEPA kullan\u0131m oran\u0131n\u0131 a\u015fa\u011f\u0131daki y\u00fczdelerde ifade etmi\u015ftir;<\/p>\n<p>&nbsp;<\/p>\n<table style=\"height: 311px;\" width=\"471\">\n<tbody>\n<tr>\n<td width=\"132\">\n<p style=\"text-align: center;\">Temiz Oda S\u0131n\u0131f\u0131<\/p>\n<p style=\"text-align: center;\">@ ISO14644-1<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"85\">Tavan Alan\u0131 (%)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"132\">ISO 5<\/td>\n<td width=\"85\">\n<p style=\"text-align: center;\">90<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">\n<p style=\"text-align: center;\">ISO 6<\/p>\n<\/td>\n<td style=\"text-align: center;\" width=\"85\">75<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"132\">ISO 7<\/td>\n<td width=\"85\">\n<p style=\"text-align: center;\">60<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"132\">ISO 8<\/td>\n<td width=\"85\">\n<p style=\"text-align: center;\">40<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>ISO 5\u2019ten az olan s\u0131n\u0131flara ula\u015fmak i\u00e7in HEPA de\u011fil ULPA (Ultra Low Penetration Air) filtre kullan\u0131lmas\u0131 tavsiye edilir.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20&#8243;][vc_column_text]Tavan uygulamalar\u0131nda kullan\u0131lan HEPA kutusu ve davlumbazl\u0131 filtreleri detayl\u0131 inceleyelim.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;1- HEPA KUTULARI&#8221; font_container=&#8221;tag:h3|font_size:24|text_align:left&#8221;][vc_separator color=&#8221;custom&#8221; border_width=&#8221;4&#8243; accent_color=&#8221;#324650&#8243;][vc_custom_heading text=&#8221;1.1 Test Yar\u0131kl\u0131 (Groove) Kutular&#8221; font_container=&#8221;tag:h3|font_size:20|text_align:left&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]<strong>Avantajlar\u0131;<\/strong><\/p>\n<p>*Test Yar\u0131\u011f\u0131 (Groove) (U profil) sayesinde conta s\u0131zd\u0131rmazl\u0131k testi imalat s\u00fcresince ve yerinde montajda yap\u0131labilir.<br \/>\n*\u00d6zellikle d\u00fcz conta ile 90\u00b0 k\u00f6\u015felerde tam olarak y\u00fczey s\u0131zd\u0131rmazl\u0131\u011f\u0131 sa\u011flan\u0131r (Resim 1, a).<br \/>\n*U profil y\u00fcksekli\u011fi artt\u0131r\u0131larak jel dolgulu filtrelere de uygun hale getirilebilir.<\/p>\n<p><strong>Dezavantajlar\u0131;<\/strong><\/p>\n<p>*D\u00f6kme contal\u0131 filtreler, k\u00f6\u015feleri yuvarlak d\u00f6n\u00fc\u015fl\u00fc oldu\u011fu i\u00e7in bu modele uygun olmayabilir.<br \/>\n*\u00dcretimi daha maliyetli oldu\u011fu i\u00e7in di\u011fer iki modele g\u00f6re daha pahal\u0131d\u0131r.<br \/>\n*D\u00fczg\u00fcn uygulanmam\u0131\u015f filtre contas\u0131n\u0131n birle\u015ftirme noktas\u0131 nedeniyle s\u0131zd\u0131rmazl\u0131k ya\u015fanabilir. Eksiz conta tercih edilirse bu sorun ortadan kalkar.[\/vc_column_text][vc_empty_space height=&#8221;40px&#8221;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;2- DAVLUMBAZ T\u0130P\u0130 HEPA F\u0130LTRELER&#8221; font_container=&#8221;tag:h3|font_size:24|text_align:left&#8221;][vc_separator color=&#8221;custom&#8221; border_width=&#8221;4&#8243; accent_color=&#8221;#324650&#8243;][vc_custom_heading text=&#8221;2.1 Davlumbazl\u0131 Ara B\u00f6lmeli HEPA Filtre&#8221; font_container=&#8221;tag:h3|font_size:20|text_align:left&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]<strong>Avantajlar\u0131;<\/strong><\/p>\n<p>*Mahalden ayarlanabilir \u00f6zellikte hava da\u011f\u0131t\u0131c\u0131l\u0131d\u0131r.<br \/>\n*Ara b\u00f6lme \u00fczerindeki nozul sayesinde HEPA filtre s\u0131z\u0131nt\u0131 (DOP) testinde %100 al\u0131nabilir.<br \/>\n*Ara b\u00f6lme \u00fczerindeki nozul kullan\u0131larak fark bas\u0131n\u00e7al\u0131nabilir.<\/p>\n<p><strong>Dezavantajlar\u0131;<\/strong><\/p>\n<p>*Ara b\u00f6lmesiz modele g\u00f6re (2.2) nakliye ve montaj esnas\u0131nda daha dikkat edilmelidir.<br \/>\n*Ara b\u00f6lmesiz modele g\u00f6re (2.2) filtre y\u00fczeyi daha azd\u0131r.<br \/>\n*Ara profil b\u00f6lmesi sebebiyle mahalden iki par\u00e7a olarak g\u00f6r\u00fclmektedir.<br \/>\n*Sabit hava da\u011f\u0131t\u0131c\u0131 modele g\u00f6re (2.2) biraz daha pahal\u0131d\u0131r.<br \/>\n*Filtre kirlendi\u011fi zaman komple de\u011fi\u015ftirilir.[\/vc_column_text][vc_empty_space height=&#8221;20px&#8221;][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;4839&#8243; img_size=&#8221;1000&#215;700&#8243;][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;4844&#8243; img_size=&#8221;1000&#215;700&#8243; alignment=&#8221;center&#8221;][\/vc_column_inner][\/vc_row_inner][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;100px&#8221;][vc_column_text]\u015eekil 1 Test Yar\u0131kl\u0131 (Groove) Kutu[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;100px&#8221;][vc_column_text]\u015eekil 5 Ara B\u00f6lmeli Davlumbazl\u0131 Filtre Bile\u015fenleri ve Nozullar\u0131[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;1.2 Jel Dolgulu Filtrelere Uygun Kutular (Knife Edge)&#8221; font_container=&#8221;tag:h3|font_size:20|text_align:left&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text css=&#8221;.vc_custom_1568963504664{padding-right: 1px !important;padding-left: 1px !important;}&#8221;]<strong>Avantajlar\u0131;<\/strong><\/p>\n<p>*Jel dolgulu filtreye uygun imal edildi\u011fi i\u00e7in di\u011fer iki modele g\u00f6re filtre oturma y\u00fczeyi kaynakl\u0131 s\u0131zd\u0131rmazl\u0131k riski en az olan modeldir (Resim 1, b).<\/p>\n<p><strong>Dezavantajlar\u0131;<\/strong><\/p>\n<p>*Filtre \u00e7ok fazla s\u00f6k\u00fcl\u00fcp tak\u0131l\u0131rsa jel bozulabilir.<br \/>\n*Uzun s\u00fcreli kullan\u0131mlarda (5 y\u0131l \u00fczeri) jel \u00f6zelli\u011fini kaybedebilir.<br \/>\n*Test groove olmayan modellerde HEPA filtre s\u0131z\u0131nt\u0131 (EMERY(DOP)) testinden \u00f6nce conta y\u00fczey testi yap\u0131lamaz.[\/vc_column_text][vc_empty_space height=&#8221;20px&#8221;][vc_row_inner][vc_column_inner][vc_single_image image=&#8221;4850&#8243; img_size=&#8221;1000&#215;500&#8243;][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;2.2 Davlumbazl\u0131 Ara B\u00f6lmesiz HEPA Filtre&#8221; font_container=&#8221;tag:h3|font_size:20|text_align:left&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text css=&#8221;.vc_custom_1568962257724{padding-right: 1px !important;padding-left: 1px !important;}&#8221;]<strong>Avantajlar\u0131;<\/strong><\/p>\n<p>*Hava giri\u015finde sabit hava da\u011f\u0131t\u0131c\u0131s\u0131 vard\u0131r.<br \/>\n*Ara b\u00f6lme olmad\u0131\u011f\u0131 i\u00e7in filtre y\u00fczeyi geni\u015ftir.<br \/>\n*Ara b\u00f6lmeli modele g\u00f6re (2.1) biraz ucuzdur.<br \/>\n*Mahalden karolaj ile birlikte g\u00f6rsel olarak b\u00fct\u00fcnl\u00fck sa\u011flar<\/p>\n<p><strong>Dezavantajlar\u0131;<\/strong><\/p>\n<p>*Hava da\u011f\u0131t\u0131c\u0131s\u0131 ayarlanabilir olmad\u0131\u011f\u0131 i\u00e7in debi ayar\u0131 mahalden yap\u0131lamaz.<br \/>\n*Filtre \u00fczerinden HEPA filtre s\u0131z\u0131nt\u0131 (DOP) testinde %100 al\u0131namaz. Ancak tavana konulacak nozul ile bu durum ortadan kalkar (1 nozul en fazla alt\u0131 filtre i\u00e7indir).<br \/>\n*Filtre kirlendi\u011fi zaman komple de\u011fi\u015ftirilir[\/vc_column_text][vc_empty_space height=&#8221;20px&#8221;][vc_row_inner][vc_column_inner][vc_single_image image=&#8221;4848&#8243; img_size=&#8221;1000&#215;700&#8243;][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]\u015eekil 2 Jel Dolgulu Filtrelere Uygun Kutu (Knife Edge)[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]\u015eekil 6 Ara B\u00f6lmesiz Davlumbazl\u0131 Filtre[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;1.3 D\u00fcz Y\u00fczey Basmal\u0131 Kutular&#8221; font_container=&#8221;tag:h3|font_size:20|text_align:left&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]<strong>Avantajlar\u0131;<\/strong><\/p>\n<p>*En \u00e7ok tercih edilen d\u00f6kme contal\u0131 filtreler bu modelde kullan\u0131labilir (Resim 1, c).<br \/>\n*\u0130malat\u0131 di\u011fer iki modele g\u00f6re daha kolay oldu\u011fu i\u00e7in fiyat avantaj\u0131 vard\u0131r.<\/p>\n<p><strong>Dezavantajlar\u0131;<\/strong><\/p>\n<p>*Filtre oturma y\u00fczeyi d\u00fczg\u00fcn de\u011filse (terazide de\u011filse) filtre oturma y\u00fczeyi kaynakl\u0131 s\u0131zd\u0131rmazl\u0131kta s\u0131k\u0131nt\u0131 ya\u015fanabilir.<br \/>\n* Filtre oturma y\u00fczeyi d\u00fcz oldu\u011fu i\u00e7in HEPA filtre s\u0131z\u0131nt\u0131 testinden \u00f6nce conta y\u00fczey testi yap\u0131lamaz.<\/p>\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][vc_empty_space height=&#8221;20px&#8221;][vc_row_inner][vc_column_inner][vc_single_image image=&#8221;4832&#8243; img_size=&#8221;1000&#215;700&#8243;][vc_column_text]\u015eekil 3 D\u00fcz Y\u00fczey Basmal\u0131 Kutu[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;2.3 De\u011fi\u015ftirilebilir Jel Contal\u0131 Filtreye Uygun Davlumbazl\u0131 Filtre&#8221; font_container=&#8221;tag:h3|font_size:20|text_align:left&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]<strong>Avantajlar\u0131<\/strong>;<\/p>\n<p>*Filtresi mahalden de\u011fi\u015ftirilebilir.<br \/>\n*Hava giri\u015finde sabit hava da\u011f\u0131t\u0131c\u0131s\u0131 vard\u0131r.<br \/>\n*Mahalden karolaj ile birlikte g\u00f6rsel olarak b\u00fct\u00fcnl\u00fck sa\u011flar.<br \/>\n*Ara b\u00f6lme olmad\u0131\u011f\u0131 i\u00e7in filtre y\u00fczeyi geni\u015ftir<\/p>\n<p><strong>Dezavantajlar\u0131;<\/strong><\/p>\n<p>*Hava da\u011f\u0131t\u0131c\u0131s\u0131 ayarlanabilir olmad\u0131\u011f\u0131 i\u00e7in debi ayar\u0131 yap\u0131lamaz.<br \/>\n*Filtre \u00fczerinden HEPA filtre s\u0131z\u0131nt\u0131 (DOP) testinde<br \/>\n%100 al\u0131namaz. Ancak tavana konulacak nozul ile bu durum ortadan kalkar (1 nozul en fazla alt\u0131 filtre i\u00e7indir).<br \/>\n*Di\u011fer iki modele g\u00f6re daha pahal\u0131d\u0131r.<br \/>\n*S\u0131k\u0131\u015ft\u0131rma \u00e7ubuklar\u0131 sebebiyle kenar geni\u015fli\u011fi di\u011fer modellerden biraz fazlad\u0131r.[\/vc_column_text][vc_empty_space height=&#8221;20px&#8221;][vc_row_inner][vc_column_inner][vc_single_image image=&#8221;4823&#8243; img_size=&#8221;1000&#215;700&#8243;][vc_empty_space height=&#8221;55px&#8221;][vc_column_text]\u015eekil 7 De\u011fi\u015ftirilebilir Jel Contal\u0131 Filtreye Uygun Davlumbazl\u0131 Filtre[\/vc_column_text][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]<strong>Ortak \u00d6zellikler;<\/strong><\/p>\n<p>\u2022 Damperli modellerinde tavan aras\u0131ndan k\u0131smi debi ayar\u0131 yap\u0131labilir.<br \/>\n\u2022 Her t\u00fcrl\u00fc tavan \u015fekline g\u00f6re (clip-in, panel, al\u00e7\u0131pan, T profil vs.) tasar\u0131m yap\u0131labilir.<br \/>\n\u2022 HEPA filtrenin mahalden de\u011fi\u015ftirilmesine olanak sa\u011flar.<br \/>\n\u2022 Swirl dif\u00fcz\u00f6r, kare anemostat, perfore menfez vs. hava da\u011f\u0131t\u0131c\u0131lar\u0131na uygundur.<br \/>\n\u2022 Paslanmaz ve boyal\u0131 \u00fcretilebilir.<br \/>\n\u2022 Tavan aras\u0131 dar olan yerlerde yandan bo\u011fazl\u0131 olarak \u00fcretim yap\u0131labilir.<br \/>\n\u2022 \u0130ste\u011fe ve tasar\u0131ma ba\u011fl\u0131 olarak HEPA filtre s\u0131z\u0131nt\u0131 (DOP) ve \u0394P nozullar\u0131 konulabilir.[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]<strong>Ortak \u00d6zellikler;<\/strong><\/p>\n<p>\u2022 Al\u00fcminyum kapak ve istenen \u00e7apta bo\u011faz \u00f6l\u00e7\u00fcs\u00fc<br \/>\n\u2022 Bireysel s\u0131zd\u0131rmazl\u0131k test sertifikal\u0131<br \/>\n\u2022 %100 s\u0131zd\u0131rmazl\u0131k garantili mod\u00fcl ve filtre<br \/>\n\u2022 Mevcut filtreler ile de\u011fi\u015ftirilebilme<br \/>\n\u2022 Vida veya ba\u011flant\u0131 eleman\u0131 olmadan montaj edilebilme<br \/>\n\u2022 HEPA filtre s\u0131z\u0131nt\u0131 (DOP) ve \u0394P nozullar\u0131 hava giri\u015f taraf\u0131nda standart (2.1)<br \/>\n\u2022 Hafif ve montaja haz\u0131r tasar\u0131m[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;4868&#8243; img_size=&#8221;1000&#215;700&#8243;][vc_column_text]\u015eekil 4 HEPA Kutusunda HEPA Filtre S\u0131z\u0131nt\u0131 (DOP) Nozulu[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;4870&#8243; img_size=&#8221;1000&#215;700&#8243;][vc_column_text]\u015eekil 8 Davlumbazl\u0131 Filtrede HEPA Filtre S\u0131z\u0131nt\u0131 (DOP) Nozulu[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;40px&#8221;][vc_single_image image=&#8221;4874&#8243; img_size=&#8221;800&#215;200&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;40px&#8221;][vc_custom_heading text=&#8221;HEPA Filtre Kutular\u0131 ile Davlumbazl\u0131 HEPA Filtre Modellerinin Kar\u015f\u0131la\u015ft\u0131r\u0131lmas\u0131;&#8221; font_container=&#8221;tag:h3|font_size:20|text_align:left&#8221;][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;4876&#8243; img_size=&#8221;400X300&#8243;][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;4878&#8243; img_size=&#8221;400&#215;300&#8243;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;HEPA F\u0130LTRE KUTUSU&#8221; font_container=&#8221;tag:h3|font_size:20|text_align:left&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]*Her temizoda klas\u0131nda kullan\u0131l\u0131r<\/p>\n<p>*Kutu, HEPA filtre ve menfezden olu\u015fur. Bu \u00fc\u00e7 eleman\u0131n uyumu \u00f6nemlidir ve dikkatli bir se\u00e7im gerektirir.<\/p>\n<p>* Kutu, HEPA filtre ve menfezden olu\u015ftu\u011fu i\u00e7in daha pahal\u0131d\u0131r.<\/p>\n<p>*\u0130lk yat\u0131r\u0131m maliyeti y\u00fcksek olmas\u0131na ra\u011fmen, i\u015fletme maliyeti a\u00e7\u0131s\u0131ndan daha uygundur. Filtre kirlendi\u011finde sadece filtre de\u011fi\u015fimi yap\u0131lacakt\u0131r. Yat\u0131r\u0131m\u0131n uzun s\u00fcreli olmas\u0131 durumunda kutu tercihi yap\u0131labilir.<\/p>\n<p>* Tavan ve kutu aras\u0131ndaki montaj uyumuyla filtre de\u011fi\u015fim s\u0131ras\u0131nda mahalin kirlenmesi \u00f6nlenir.<\/p>\n<p>* Her t\u00fcrl\u00fc tavan \u015fekline g\u00f6re (clip-in, panel, al\u00e7\u0131pan, T profil vs.) tasar\u0131m yap\u0131labilir.<\/p>\n<p>* Daha a\u011f\u0131rd\u0131r.* Standart tasar\u0131mda kutu daha y\u00fcksektir.<\/p>\n<p>* Swirl dif\u00fcz\u00f6r, kare anemostat, perfore menfez vs. hava da\u011f\u0131t\u0131c\u0131lar\u0131na uygundur.<\/p>\n<p>* Paslanmaz ve f\u0131r\u0131n boyal\u0131 \u00fcretilebilir.<\/p>\n<p>* Tavan durumuna g\u00f6re yandan bo\u011fazl\u0131 olarak \u00fcretilerek montaj kolayl\u0131\u011f\u0131 sa\u011flar.<\/p>\n<p>* \u0130lk montaj\u0131 davlumbazl\u0131 filtreye g\u00f6re daha uzun s\u00fcrede yap\u0131l\u0131r.<\/p>\n<p>* Tavan ve kutu aras\u0131ndaki montaj uyumuyla tavan ile menfez y\u00fczeyi ayn\u0131 seviyede (hemy\u00fcz) b\u0131rak\u0131labilir.<\/p>\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_custom_heading text=&#8221;DAVLUMBAZLI HEPA F\u0130LTRE&#8221; font_container=&#8221;tag:h3|font_size:20|text_align:left&#8221;][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]*Her oda klas\u0131nda kullan\u0131labilir, ancak \u00f6zellikle ISO 8 gibi tavan y\u00fczeyinde daha az HEPA kullan\u0131mlar\u0131nda menfez olmad\u0131\u011f\u0131 i\u00e7in oda i\u00e7inde \u00f6l\u00fc hacimler daha fazla kalabilir. \u0130yi bir emi\u015f sistemi ile bu en aza indirilebilir.<\/p>\n<p>*Kompakt bir mod\u00fcl oldu\u011fu i\u00e7in s\u0131zd\u0131rmazl\u0131k riski daha azd\u0131r.*Belli parametreler g\u00f6zetilerek se\u00e7ilmi\u015f kutulardan (filtre ve menfezi olan) daha ucuzdur.<\/p>\n<p>*\u0130lk yat\u0131r\u0131m maliyeti uygun olmas\u0131na ra\u011fmen, i\u015fletme maliyeti a\u00e7\u0131s\u0131ndan daha pahal\u0131d\u0131r. Filtre kirlendi\u011finde komple bir de\u011fi\u015fim gerektirir. Bu y\u00fczden s\u0131k filtre de\u011fi\u015fimlerinde tercih edilmeyebilir.<\/p>\n<p>*Alttan filtre de\u011fi\u015fimli modeli se\u00e7ilmedi\u011fi takdirde davlumbazl\u0131 filtre montaj\u0131 tavandan yap\u0131l\u0131r. Bu nedenle mahal kirlenebilir.<\/p>\n<p>* Panel ve T profil tavanlar\u0131na daha uygundur. Clip-in tavan i\u00e7in aparat yap\u0131lmas\u0131 gerekmektedir. Al\u00e7\u0131pan tavanlarda filtre de\u011fi\u015fimi s\u0131k\u0131nt\u0131l\u0131d\u0131r.<\/p>\n<p>* Daha hafiftir.<\/p>\n<p>* Standart profillerden imal edildi\u011fi i\u00e7in daha kompakt bir yap\u0131s\u0131 vard\u0131r. \u00c7er\u00e7eve y\u00fcksekli\u011fi kutudan azd\u0131r.<\/p>\n<p>* Swirl dif\u00fcz\u00f6r, kare anemostat, perfore menfez vs. uygulamas\u0131na uygun de\u011fildir.<\/p>\n<p>* Standart eloksall\u0131 al\u00fcminyum profil yap\u0131s\u0131na sahiptir.<\/p>\n<p>* Standart olarak \u00fcstten bo\u011fazl\u0131d\u0131r.<\/p>\n<p>* Montaj\u0131 daha k\u0131sa s\u00fcrede yap\u0131labilir.<\/p>\n<p>*Filtre profili nedeniyle y\u00fczey koruma (faceguard) tavan ile ayn\u0131 seviyede de\u011fildir.<\/p>\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][vc_column_text]Tavanda HEPA kullan\u0131m\u0131nda ister kutulu ister davlumbazl\u0131 filtre uygulamas\u0131 yap\u0131ls\u0131n dikkat edilmesi gereken temel hususlar vard\u0131r. Temel hatlar\u0131yla bu hususlar a\u015fa\u011f\u0131da verilmi\u015ftir;<\/p>\n<ul>\n<li><strong>Hava debisine g\u00f6re uygun modelin se\u00e7imi:<\/strong> Projeye ve standartlara uygun olarak tasar\u0131m yap\u0131lmal\u0131d\u0131r. Burada kar\u015f\u0131la\u015f\u0131lan temel sorun uygulamada gerekli olan kutu adedi azals\u0131n diye tavandaki her bir HEPA filtreden nominalden fazla hava debisi ge\u00e7irilmek istenmesidir. Al\u0131n h\u0131z\u0131, ilk ba\u015flama bas\u0131nc\u0131, son kirlenme bas\u0131nc\u0131, filtrasyon h\u0131z\u0131 gibi kriterler dikkate al\u0131narak ve \u00f6zellikle uygulama yap\u0131lacak i\u015fletmedeki m\u00fchendislik ve kalite y\u00f6netim sistemlerden sorumlu ki\u015filerle yap\u0131lacak mutabakat ile sonradan \u00e7\u0131kmas\u0131 muhtemel problemler ortadan kald\u0131r\u0131lacakt\u0131r.<\/li>\n<li><strong>Uygun asma tavan\u0131n se\u00e7ilmesi<\/strong>: Kutu ile asma tavan\u0131n uyumu \u00f6nemlidir. Kutular t\u00fcm tavan \u00e7e\u015fitlerine uygulanabilir olmas\u0131na ra\u011fmen montaj ve i\u015fletme kolayl\u0131\u011f\u0131 i\u00e7in asma tavan\u0131n do\u011fru se\u00e7ilmesi \u00f6nemlidir.<\/li>\n<li><strong>Tavan yap\u0131s\u0131 ile uygulanacak modelin uyumu<\/strong>: Bu konu mutlaka \u00fcretici &amp; taahh\u00fct yapan firma &amp; partisyon \u00fcreticisi aras\u0131nda bir koordinasyon ile belirlenmeli ve gerekmesi durumunda imalata ba\u015flamadan \u00f6nce numune \u00e7al\u0131\u015fmas\u0131 yap\u0131lmal\u0131d\u0131r.<\/li>\n<li><strong>Uygun dif\u00fcz\u00f6r\u00fcn se\u00e7ilmesi<\/strong>: Se\u00e7ilecek dif\u00fcz\u00f6r\u00fcn, kutu ve asma tavana uygun se\u00e7ilmesi \u00f6nemlidir. Bu yap\u0131 mahalden g\u00f6r\u00fclecek ve i\u015fletme s\u0131ras\u0131nda filtre de\u011fi\u015fiminde s\u00f6k\u00fcl\u00fcp tak\u0131lacakt\u0131r. Yap\u0131lacak se\u00e7imin g\u00f6rsel kriterler ve ilerde filtre de\u011fi\u015fimi s\u0131ras\u0131nda g\u00f6r\u00fcnt\u00fc kirlili\u011fi yaratmamas\u0131 i\u00e7in \u00f6nemlidir. Son d\u00f6nem uygulamalar\u0131 genellikle dif\u00fcz\u00f6r\u00fcn kutu i\u00e7inde kalmas\u0131 y\u00f6n\u00fcndedir.<\/li>\n<li><strong>HEPA filtre ile kutunun uyumu:<\/strong> Yukar\u0131da uygulanacak modele g\u00f6re hangi filtrenin hangi kutuya uygun oldu\u011fu anlat\u0131lm\u0131\u015ft\u0131r. Taahh\u00fct firmas\u0131, uygulanacak modele g\u00f6re filtre \u00fcreticisinden uygun filtrenin se\u00e7ilmesine dikkat etmelidir. Bu husus olduk\u00e7a \u00f6nemlidir. Taahh\u00fct firmas\u0131 \u00e7o\u011fu zaman kutuyu, dif\u00fcz\u00f6r\u00fc ve HEPA filtreyi farkl\u0131 tedarik\u00e7ilerden temin edebilmektedir. Ya da komple ayn\u0131 tedarik\u00e7iden temin etse bile hepsinin yukar\u0131da anlat\u0131lan kriterlere uygun olup olmad\u0131\u011f\u0131n\u0131 mutlaka kontrol etmeli ya da sipari\u015f a\u015famas\u0131nda bunlar\u0131 sorgulamal\u0131d\u0131r.<\/li>\n<li><strong>HEPA Filtre S\u0131z\u0131nt\u0131 (DOP) ve <\/strong><strong>\u2206<\/strong><strong>P nozullar\u0131n\u0131n se\u00e7imi<\/strong>: M\u00fchendislik firmas\u0131 sipari\u015f a\u015famas\u0131na ge\u00e7meden \u00f6nce uygulanacak tavan HEPA filtre modelinde filtre kirlili\u011fini izlemek i\u00e7in ve s\u0131zd\u0131rmazl\u0131k testinin yap\u0131labilmesi i\u00e7in konulacak nozullarin tespitini yapmal\u0131d\u0131r (\u015eekil 3.1.1). Bu se\u00e7imi yaparken i\u015fletme yetkilileri, kalifikasyon b\u00f6l\u00fcm\u00fc, partisyon firmas\u0131 ve \u00fcretici ile koordinasyon halinde olmal\u0131d\u0131r.<\/li>\n<\/ul>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][vc_single_image image=&#8221;4880&#8243; img_size=&#8221;400&#215;300&#8243; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator color=&#8221;custom&#8221; border_width=&#8221;4&#8243; accent_color=&#8221;#324650&#8243;][vc_custom_heading text=&#8221;Sonu\u00e7;&#8221; font_container=&#8221;tag:h3|font_size:24|text_align:left|color:%23212121&#8243; use_theme_fonts=&#8221;yes&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]Yukar\u0131daki anlat\u0131lan hususlardan dolay\u0131 tavanda uygulanacak HEPA filtre modelinin do\u011fru se\u00e7ilmesi olduk\u00e7a \u00f6nemlidir. Kurulan sistemin mahalden g\u00f6r\u00fclen en \u00f6nemli eleman\u0131 bu uygulamad\u0131r. Bu sistemin belli aral\u0131klarla kontrol edildi\u011fini ve s\u0131z\u0131nt\u0131 testinin yap\u0131ld\u0131\u011f\u0131n\u0131 d\u00fc\u015f\u00fcn\u00fcrsek bu se\u00e7imin ne kadar b\u00fcy\u00fck \u00f6nem ta\u015f\u0131d\u0131\u011f\u0131 g\u00f6r\u00fcl\u00fcr. Piyasada yap\u0131lan en b\u00fcy\u00fck hata bu hususlar dikkate al\u0131nmadan se\u00e7im yap\u0131lmas\u0131d\u0131r. Bilgi eksikli\u011finden, bu i\u015fi sat\u0131n alacak ki\u015filerin maliyet odakl\u0131 olmas\u0131ndan, i\u015fin gere\u011finden ucuza al\u0131nm\u0131\u015f olmas\u0131ndan ve bunun gibi sebeplerden dolay\u0131 hatalar yap\u0131labilmektedir. Uygun olmayan kutunun se\u00e7ilmesi ve sipari\u015f edilmesi, gelen kutuya uygun olarak tavana zorlama \u00e7\u00f6z\u00fcmlerle kutu montaj\u0131n\u0131n yap\u0131lmas\u0131 ve kutu-filtre uyumsuzlu\u011fu i\u00e7inden \u00e7\u0131k\u0131lmaz problemler olu\u015fturmaktad\u0131r. Bunlar s\u0131kl\u0131kla kar\u015f\u0131la\u015ft\u0131\u011f\u0131m\u0131z s\u0131k\u0131nt\u0131lard\u0131r. Hatta bu konuyu ele al\u0131p yazma sebebimiz, bu \u00f6nemli hususlar\u0131n maalesef \u00fclkemizin \u00f6nemli yat\u0131r\u0131mlar\u0131nda g\u00f6z ard\u0131 edilerek maliyet odakl\u0131 yakla\u015f\u0131mlar\u0131n sergilenmesi ve insan sa\u011fl\u0131\u011f\u0131n\u0131n neredeyse hi\u00e7e say\u0131lmas\u0131d\u0131r.[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_separator color=&#8221;custom&#8221; border_width=&#8221;4&#8243; accent_color=&#8221;#324650&#8243;][vc_custom_heading text=&#8221;Kaynaklar:&#8221; font_container=&#8221;tag:h3|font_size:24|text_align:left|color:%23212121&#8243; use_theme_fonts=&#8221;yes&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_empty_space height=&#8221;20px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]1. Prof. Dr. F. Taner \u00d6ZKAYNAK \/ Tetisan Teknik Yay\u0131nlar\u0131<br \/>\n2. ISO 14644-1:2015 Temizoda Standard\u0131<br \/>\n3. NAFA Guide to Air Filtration \/ Fifth Edition: 2014 (Chapter 9)<br \/>\n4. ULPATEK Air Filter Technology<br \/>\n5. EN ISO 29463-4:2011 High-Efficiency Filters and Filter Media for Removing Particles in Air &#8211; Part 4:<br \/>\nTest Method for Determining Leakage of Filter Elements-Scan Method<br \/>\n6. IEST-RP-CC034.2 HEPA and ULPA Filter Leak Tests<br \/>\n7. Cleanroom Technology: Fundamentals of Design, Testing and Operation \/ Second Edition, W. Whyte<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row][vc_row][vc_column][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;2\/3&#8243;][vc_column_text] &nbsp; Hijyenik klima sistemlerin tasar\u0131m\u0131nda dikkate al\u0131nmas\u0131 gereken parametrelerin ba\u015f\u0131nda ortamda bulunabilecek maksimum partik\u00fcl konsantrasyonu ve \u00e7ap\u0131 gelir. Bunun d\u0131\u015f\u0131nda s\u0131cakl\u0131k, nem, bas\u0131n\u00e7, ses \u015fiddeti, titre\u015fim, statik elektrik gibi parametrelerin de kontrol alt\u0131na al\u0131nmas\u0131 gerekir. Konumuzun ba\u015fl\u0131\u011f\u0131nda da anla\u015f\u0131laca\u011f\u0131 gibi hijyenik klima sistemlerinde istenilen maksimum partik\u00fcl konsantrasyonu ve \u00e7ap\u0131n\u0131 yakalamak i\u00e7in kullan\u0131lan HEPA [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":4887,"parent":2852,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-4808","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/pages\/4808","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/comments?post=4808"}],"version-history":[{"count":44,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/pages\/4808\/revisions"}],"predecessor-version":[{"id":4889,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/pages\/4808\/revisions\/4889"}],"up":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/pages\/2852"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/media\/4887"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/tr\/wp-json\/wp\/v2\/media?parent=4808"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}