{"id":14378,"date":"2026-09-23T12:50:04","date_gmt":"2026-09-23T09:50:04","guid":{"rendered":"https:\/\/www.ulpatek.com\/tecnologia-de-filtracao\/comparacao-de-normas-de-filtros\/"},"modified":"2026-09-29T15:58:23","modified_gmt":"2026-09-29T12:58:23","slug":"comparacao-de-normas-de-filtros","status":"publish","type":"page","link":"https:\/\/www.ulpatek.com\/pt-pt\/tecnologia-de-filtracao\/comparacao-de-normas-de-filtros\/","title":{"rendered":"Compara\u00e7\u00e3o de normas de filtros: ISO 16890, EN 779 e MERV"},"content":{"rendered":"<style>\n.ulp-doc{font-size:16px;line-height:1.65}\n.ulp-doc h2{margin:38px 0 14px;font-size:26px;line-height:1.3}\n.ulp-doc h3{margin:26px 0 10px;font-size:19px;line-height:1.35}\n.ulp-doc p{margin:0 0 16px}\n.ulp-doc ul{margin:0 0 20px 20px}\n.ulp-doc li{margin:0 0 8px}\n.ulp-doc .tbl{overflow-x:auto;margin:0 0 28px;-webkit-overflow-scrolling:touch}\n.ulp-doc table{width:100%;border-collapse:collapse;font-size:15px;min-width:520px}\n.ulp-doc th,.ulp-doc td{border:1px solid #d8dde0;padding:9px 11px;vertical-align:top;text-align:left}\n.ulp-doc th{background:#eef3f6;font-weight:600}\n.ulp-doc tbody tr:nth-child(even){background:#fafbfc}\n.ulp-doc .lead{font-size:17px;background:#f4f8fa;border-left:4px solid #1f4e79;padding:16px 18px;margin:0 0 24px}\n<\/style>\n<div class=\"ulp-doc\">\n<h2>Resposta curta<\/h2>\n<p class=\"lead\"><strong>A ISO 16890 \u00e9 a norma internacional em vigor para os filtros de ar utilizados em ventila\u00e7\u00e3o geral. Substituiu a EN 779:2012, que foi cancelada em toda a Europa a 30 de junho de 2018. N\u00e3o existe uma convers\u00e3o exata, de um para um, entre as duas: um filtro F7 n\u00e3o \u00abequivale\u00bb a uma classe ISO 16890 concreta, mas apenas a um intervalo de classes poss\u00edveis.<\/strong> A ISO 16890 classifica o filtro pela fra\u00e7\u00e3o do material particulado em suspens\u00e3o no ar que ele ret\u00e9m &ndash; ePM<sub>1<\/sub>, ePM<sub>2,5<\/sub>, ePM<sub>10<\/sub> ou ISO Coarse &ndash; e n\u00e3o pela efici\u00eancia num \u00fanico tamanho de part\u00edcula de 0,4\u00a0&micro;m. O MERV (ANSI\/ASHRAE 52.2) continua a ser um sistema norte-americano distinto e tamb\u00e9m n\u00e3o tem equival\u00eancia exata com nenhuma das duas.<\/p>\n<h3>Factos essenciais<\/h3>\n<ul>\n<li><strong>Norma em vigor:<\/strong> EN ISO 16890, em quatro partes &ndash; parte 1 (classifica\u00e7\u00e3o): ISO 16890-1:2016; parte 2 (efici\u00eancia fracional e resist\u00eancia ao escoamento do ar): ISO 16890-2:2022; parte 3 (efici\u00eancia gravim\u00e9trica e capacidade de reten\u00e7\u00e3o de poeiras): ISO 16890-3:2024; parte 4 (condicionamento com isopropanol): ISO 16890-4:2022.<\/li>\n<li><strong>Norma cancelada:<\/strong> EN 779:2012 &ndash; classes G1&ndash;G4, M5&ndash;M6, F7&ndash;F9. J\u00e1 n\u00e3o \u00e9 v\u00e1lida para a classifica\u00e7\u00e3o de produtos novos nos pa\u00edses membros do CEN.<\/li>\n<li><strong>Acima da ISO 16890:<\/strong> os filtros EPA, HEPA e ULPA n\u00e3o s\u00e3o abrangidos pela ISO 16890. S\u00e3o classificados segundo a EN 1822 (E10&ndash;U17) e a ISO 29463 (ISO 15 E &ndash; ISO 75 U).<\/li>\n<li><strong>Am\u00e9rica do Norte:<\/strong> MERV 1&ndash;16, segundo a ANSI\/ASHRAE 52.2. Os valores MERV 17&ndash;20 aparecem em alguma literatura, mas est\u00e3o fora do \u00e2mbito do m\u00e9todo de ensaio da 52.2.<\/li>\n<li><strong>Convers\u00e3o:<\/strong> s\u00f3 existem intervalos indicativos. Pe\u00e7a sempre o relat\u00f3rio de ensaio ISO 16890 do filtro em causa.<\/li>\n<\/ul>\n<h2>Porque foi substitu\u00edda a EN 779<\/h2>\n<p>A EN 779:2012 classificava o filtro pela efici\u00eancia m\u00e9dia num \u00fanico tamanho de part\u00edcula &ndash; 0,4\u00a0&micro;m &ndash; medida enquanto o filtro era carregado com p\u00f3 sint\u00e9tico. Esse valor dizia muito pouco sobre o efeito real do filtro na poeira que as pessoas respiram.<\/p>\n<p>A ISO 16890 mede a efici\u00eancia fracional em toda a gama de 0,3&ndash;10\u00a0&micro;m e pondera depois o resultado com as distribui\u00e7\u00f5es granulom\u00e9tricas reais do ar exterior urbano e rural. O resultado \u00e9 a percentagem de PM<sub>1<\/sub>, PM<sub>2,5<\/sub> ou PM<sub>10<\/sub> que o filtro ret\u00e9m &ndash; as mesmas fra\u00e7\u00f5es de material particulado utilizadas pela Organiza\u00e7\u00e3o Mundial da Sa\u00fade e pela legisla\u00e7\u00e3o sobre a qualidade do ar. O projetista pode, assim, relacionar diretamente uma classe de filtro com um objetivo de qualidade do ar interior.<\/p>\n<h3>As principais diferen\u00e7as<\/h3>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>&nbsp;<\/th>\n<th>EN 779:2012 (cancelada)<\/th>\n<th>EN ISO 16890<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tamanho de part\u00edcula avaliado<\/td>\n<td>Apenas 0,4\u00a0&micro;m<\/td>\n<td>0,3\u00a0&micro;m &ndash; 10\u00a0&micro;m<\/td>\n<\/tr>\n<tr>\n<td>Classes<\/td>\n<td>G1&ndash;G4, M5&ndash;M6, F7&ndash;F9<\/td>\n<td>ISO Coarse, ISO ePM<sub>10<\/sub>, ISO ePM<sub>2,5<\/sub>, ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>Carga eletrost\u00e1tica<\/td>\n<td>Amostra de meio filtrante descarregada (efici\u00eancia m\u00ednima)<\/td>\n<td>Elemento filtrante completo condicionado em vapor de isopropanol<\/td>\n<\/tr>\n<tr>\n<td>P\u00f3 de ensaio<\/td>\n<td>P\u00f3 sint\u00e9tico ASHRAE<\/td>\n<td>P\u00f3 de ensaio ISO A2 Fine<\/td>\n<\/tr>\n<tr>\n<td>Perda de carga final de ensaio<\/td>\n<td>Classes G: 250\u00a0Pa; classes M e F: 450\u00a0Pa<\/td>\n<td>ISO Coarse \/ ePM<sub>10<\/sub> &lt; 50%: 200\u00a0Pa; ePM<sub>x<\/sub> &ge; 50%: 300\u00a0Pa<\/td>\n<\/tr>\n<tr>\n<td>\u00c2mbito geogr\u00e1fico<\/td>\n<td>Europa (CEN)<\/td>\n<td>Internacional (ISO)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Como se atribui uma classe ISO 16890<\/h2>\n<p>O filtro \u00e9 classificado no grupo mais elevado cujo requisito cumpre, e a efici\u00eancia declarada \u00e9 arredondada <em>por defeito<\/em> em passos de 5%.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Grupo<\/th>\n<th>Requisito<\/th>\n<th>Declarado como<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<td>ePM<sub>1<\/sub> inicial &ge; 50% <em>e<\/em> ePM<sub>1,min<\/sub> ap\u00f3s descarga &ge; 50%<\/td>\n<td>ISO ePM<sub>1<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<td>ePM<sub>2,5<\/sub> inicial &ge; 50% <em>e<\/em> ePM<sub>2,5,min<\/sub> ap\u00f3s descarga &ge; 50%<\/td>\n<td>ISO ePM<sub>2,5<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<td>ePM<sub>10<\/sub> inicial &ge; 50% (sem requisito ap\u00f3s descarga)<\/td>\n<td>ISO ePM<sub>10<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO Coarse<\/td>\n<td>ePM<sub>10<\/sub> &lt; 50%<\/td>\n<td>ISO Coarse 5% &hellip; 95% (efici\u00eancia gravim\u00e9trica)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Exemplo pr\u00e1tico.<\/strong> Um filtro V-Compact anteriormente classificado como F8 segundo a EN 779 \u00e9 ensaiado segundo a ISO 16890 e obt\u00e9m 73% em ePM<sub>1<\/sub>, 80% em ePM<sub>2,5<\/sub> e 93% em ePM<sub>10<\/sub>. Como cumpre o requisito de ePM<sub>1<\/sub>, \u00e9 classificado no grupo mais elevado em que se enquadra, e o valor \u00e9 arredondado por defeito em passos de 5%: <strong>ISO ePM<sub>1<\/sub> 70%<\/strong>.<\/p>\n<p>O \u00abe\u00bb significa efici\u00eancia; o \u00edndice indica a fra\u00e7\u00e3o de material particulado. ISO ePM<sub>1<\/sub> 70% significa que o filtro ret\u00e9m 70% das part\u00edculas PM<sub>1<\/sub>.<\/p>\n<h2>Da EN 779 \u00e0 ISO 16890: intervalos indicativos, n\u00e3o equival\u00eancias<\/h2>\n<p>Uma mesma classe EN 779 pode corresponder a v\u00e1rias classes ISO 16890 diferentes, consoante o meio filtrante utilizado. Dois filtros com a mesma etiqueta F7 podem ser classificados, respetivamente, como ISO ePM<sub>1<\/sub> 50% e ISO ePM<sub>2,5<\/sub> 65%. Isto \u00e9 particularmente vis\u00edvel nos meios sint\u00e9ticos com carga eletrost\u00e1tica (electret), cuja efici\u00eancia baixa assim que essa carga \u00e9 neutralizada &ndash; exatamente o que o passo de condicionamento da ISO 16890 p\u00f5e a descoberto.<\/p>\n<p>A tabela seguinte indica o intervalo de efici\u00eancias m\u00e9dias medidas que os filtros de cada antiga classe EN 779 costumam apresentar quando s\u00e3o reensaiados segundo a ISO 16890. <strong>Utilize-a para restringir a pr\u00e9-sele\u00e7\u00e3o, nunca como substituto do relat\u00f3rio de ensaio.<\/strong><\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Classe EN 779:2012<\/th>\n<th>ePM<sub>1<\/sub><\/th>\n<th>ePM<sub>2,5<\/sub><\/th>\n<th>ePM<sub>10<\/sub><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>M5<\/td>\n<td>5% &ndash; 35%<\/td>\n<td>10% &ndash; 40%<\/td>\n<td>40% &ndash; 70%<\/td>\n<\/tr>\n<tr>\n<td>M6<\/td>\n<td>10% &ndash; 40%<\/td>\n<td>20% &ndash; 50%<\/td>\n<td>60% &ndash; 80%<\/td>\n<\/tr>\n<tr>\n<td>F7<\/td>\n<td>40% &ndash; 65%<\/td>\n<td>65% &ndash; 75%<\/td>\n<td>80% &ndash; 90%<\/td>\n<\/tr>\n<tr>\n<td>F8<\/td>\n<td>65% &ndash; 90%<\/td>\n<td>75% &ndash; 95%<\/td>\n<td>90% &ndash; 100%<\/td>\n<\/tr>\n<tr>\n<td>F9<\/td>\n<td>80% &ndash; 90%<\/td>\n<td>85% &ndash; 95%<\/td>\n<td>90% &ndash; 100%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Os filtros G1&ndash;G4 enquadram-se no grupo ISO Coarse. O valor ISO Coarse destes filtros corresponde a uma efici\u00eancia gravim\u00e9trica e n\u00e3o \u00e9 compar\u00e1vel com uma efici\u00eancia ePM<sub>x<\/sub>.<\/p>\n<h2>Compara\u00e7\u00e3o com o MERV (ANSI\/ASHRAE 52.2)<\/h2>\n<p>O MERV resulta da efici\u00eancia m\u00e9dia composta por tamanho de part\u00edcula em tr\u00eas gamas: E1 = 0,30&ndash;1,0\u00a0&micro;m, E2 = 1,0&ndash;3,0\u00a0&micro;m, E3 = 3,0&ndash;10,0\u00a0&micro;m. O filtro recebe o MERV mais elevado para o qual cumpre <em>todos<\/em> os requisitos desse MERV.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>MERV<\/th>\n<th>E1 (0,30&ndash;1,0\u00a0&micro;m)<\/th>\n<th>E2 (1,0&ndash;3,0\u00a0&micro;m)<\/th>\n<th>E3 (3,0&ndash;10,0\u00a0&micro;m)<\/th>\n<th>Grupo ISO 16890 indicativo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1&ndash;4<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&lt; 20%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 20%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 35%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 50%<\/td>\n<td>ISO Coarse &ndash; ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 20%<\/td>\n<td>&ge; 70%<\/td>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 35%<\/td>\n<td>&ge; 75%<\/td>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 50%<\/td>\n<td>&ge; 80%<\/td>\n<td>ISO ePM<sub>10<\/sub> &ndash; ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>&ge; 20%<\/td>\n<td>&ge; 65%<\/td>\n<td>&ge; 85%<\/td>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>&ge; 35%<\/td>\n<td>&ge; 80%<\/td>\n<td>&ge; 90%<\/td>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>&ge; 50%<\/td>\n<td>&ge; 85%<\/td>\n<td>&ge; 90%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>&ge; 75%<\/td>\n<td>&ge; 90%<\/td>\n<td>&ge; 95%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>&ge; 85%<\/td>\n<td>&ge; 90%<\/td>\n<td>&ge; 95%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>&ge; 95%<\/td>\n<td>&ge; 95%<\/td>\n<td>&ge; 95%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>A \u00faltima coluna \u00e9 apenas uma orienta\u00e7\u00e3o aproximada. O MERV usa outro aerossol, outras gamas de tamanho e n\u00e3o inclui condicionamento com isopropanol, pelo que um filtro MERV 13 e um filtro ISO ePM<sub>1<\/sub> 50% n\u00e3o s\u00e3o, por defini\u00e7\u00e3o, intermut\u00e1veis.<\/p>\n<h2>Onde a ISO 16890 termina: EPA, HEPA e ULPA<\/h2>\n<p>A ISO 16890 abrange os filtros at\u00e9 cerca de ISO ePM<sub>1<\/sub> 95%. Acima disso, os filtros s\u00e3o ensaiados part\u00edcula a part\u00edcula no tamanho de part\u00edcula mais penetrante (MPPS), segundo a EN 1822 ou a ISO 29463, e cada elemento \u00e9 submetido a um ensaio de fugas individual.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Classe EN 1822<\/th>\n<th>Efici\u00eancia global no MPPS<\/th>\n<th>Efici\u00eancia local<\/th>\n<th>Classe ISO 29463<\/th>\n<th>Grupo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>E10<\/td>\n<td>&ge; 85%<\/td>\n<td>&ndash;<\/td>\n<td>Sem equivalente<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>E11<\/td>\n<td>&ge; 95%<\/td>\n<td>&ndash;<\/td>\n<td>ISO 15 E<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>E12<\/td>\n<td>&ge; 99,5%<\/td>\n<td>&ndash;<\/td>\n<td>ISO 25 E<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>H13<\/td>\n<td>&ge; 99,95%<\/td>\n<td>&ge; 99,75%<\/td>\n<td>ISO 35 H<\/td>\n<td>HEPA<\/td>\n<\/tr>\n<tr>\n<td>H14<\/td>\n<td>&ge; 99,995%<\/td>\n<td>&ge; 99,975%<\/td>\n<td>ISO 45 H<\/td>\n<td>HEPA<\/td>\n<\/tr>\n<tr>\n<td>U15<\/td>\n<td>&ge; 99,9995%<\/td>\n<td>&ge; 99,9975%<\/td>\n<td>ISO 55 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<tr>\n<td>U16<\/td>\n<td>&ge; 99,99995%<\/td>\n<td>&ge; 99,99975%<\/td>\n<td>ISO 65 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<tr>\n<td>U17<\/td>\n<td>&ge; 99,999995%<\/td>\n<td>&ge; 99,9999%<\/td>\n<td>ISO 75 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>A ISO 29463 come\u00e7a na classe ISO 15 E, pelo que a classe E10 da EN 1822 n\u00e3o tem correspond\u00eancia na ISO 29463. O equivalente mais pr\u00f3ximo na ISO 16890 \u00e9 ISO ePM<sub>1<\/sub> &gt; 95%.<\/p>\n<h2>Escolher a classe para um projeto<\/h2>\n<p>Parta da qualidade do ar exterior no local e da qualidade do ar interior que pretende garantir, e n\u00e3o da etiqueta do filtro antigo.<\/p>\n<ul>\n<li><strong>Pr\u00e9-filtra\u00e7\u00e3o e prote\u00e7\u00e3o dos equipamentos:<\/strong> ISO Coarse ou ISO ePM<sub>10<\/sub>. Protege as baterias, os ventiladores e os filtros a jusante contra o cot\u00e3o, os insetos e a areia.<\/li>\n<li><strong>Ventila\u00e7\u00e3o comercial corrente:<\/strong> ISO ePM<sub>1<\/sub> 50&ndash;60% \u00e9 a substitui\u00e7\u00e3o habitual do que antes se especificava como F7.<\/li>\n<li><strong>Escrit\u00f3rios e escolas em ar urbano polu\u00eddo:<\/strong> ISO ePM<sub>1<\/sub> 70&ndash;80%.<\/li>\n<li><strong>Hospitais, ind\u00fastria farmac\u00eautica e produ\u00e7\u00e3o alimentar:<\/strong> ISO ePM<sub>1<\/sub> 80% ou superior, como \u00faltimo est\u00e1gio antes de um filtro HEPA.<\/li>\n<li><strong>Salas limpas e conten\u00e7\u00e3o:<\/strong> H13, H14 ou superior, segundo a EN 1822 \/ ISO 29463, escolhidos em conjunto com a classe de sala limpa segundo a ISO 14644-1.<\/li>\n<\/ul>\n<p>A recomenda\u00e7\u00e3o Eurovent REC 4\/23 d\u00e1 orienta\u00e7\u00f5es de classe de filtro a partir da qualidade do ar exterior no local de instala\u00e7\u00e3o e da qualidade do ar interior pretendida. \u00c9 a refer\u00eancia que a maioria das especifica\u00e7\u00f5es europeias segue atualmente.<\/p>\n<h2>Perguntas frequentes<\/h2>\n<h3>A EN 779 ainda \u00e9 v\u00e1lida?<\/h3>\n<p>N\u00e3o. A EN 779:2012 foi cancelada a 30 de junho de 2018 e substitu\u00edda pela EN ISO 16890. No mercado ainda se fala informalmente de filtros \u00abF7\u00bb ou \u00abM5\u00bb, mas um filtro novo deve ser especificado, ensaiado e documentado segundo a ISO 16890.<\/p>\n<h3>Qual \u00e9 o equivalente ISO 16890 de um filtro F7?<\/h3>\n<p>N\u00e3o existe um equivalente \u00fanico. Os filtros classificados como F7 costumam obter 40&ndash;65% em ePM<sub>1<\/sub>, 65&ndash;75% em ePM<sub>2,5<\/sub> e 80&ndash;90% em ePM<sub>10<\/sub>. Na pr\u00e1tica, ISO ePM<sub>1<\/sub> 50&ndash;60% \u00e9 a substitui\u00e7\u00e3o mais frequente, mas a resposta certa para um filtro concreto s\u00f3 pode vir do seu relat\u00f3rio de ensaio.<\/p>\n<h3>O que significa ISO ePM1 70%?<\/h3>\n<p>Significa que o filtro ret\u00e9m 70% do material particulado com di\u00e2metro aerodin\u00e2mico at\u00e9 1\u00a0&micro;m. Esta efici\u00eancia \u00e9 medida em toda a gama de 0,3&ndash;10\u00a0&micro;m e ponderada por uma distribui\u00e7\u00e3o granulom\u00e9trica normalizada do ar urbano. Os valores declarados s\u00e3o arredondados por defeito em passos de 5%.<\/p>\n<h3>Porque \u00e9 que a ISO 16890 descarrega o filtro com isopropanol?<\/h3>\n<p>Muitos meios sint\u00e9ticos recorrem a uma carga eletrost\u00e1tica para reter as part\u00edculas. Essa carga dissipa-se em servi\u00e7o, pelo que a efici\u00eancia inicial sobrevaloriza o desempenho real. A ISO 16890-4 condiciona o elemento completo em vapor de isopropanol saturado e o ensaio \u00e9 repetido, de modo que a classe traduza uma efici\u00eancia que n\u00e3o depende da carga.<\/p>\n<h3>MERV 13 \u00e9 o mesmo que ISO ePM1 50%?<\/h3>\n<p>S\u00e3o, em termos gerais, compar\u00e1veis na aplica\u00e7\u00e3o, mas n\u00e3o s\u00e3o equivalentes por defini\u00e7\u00e3o. As duas normas usam aeross\u00f3is de ensaio diferentes, gamas de tamanho de part\u00edcula diferentes e condicionamentos diferentes. Um filtro deve apresentar a classifica\u00e7\u00e3o da norma indicada na especifica\u00e7\u00e3o, e n\u00e3o um valor convertido.<\/p>\n<h3>A ISO 16890 abrange os filtros HEPA?<\/h3>\n<p>N\u00e3o. A ISO 16890 termina em cerca de ISO ePM<sub>1<\/sub> 95%. Os filtros EPA, HEPA e ULPA s\u00e3o classificados pela EN 1822 ou pela ISO 29463, que ensaiam no tamanho de part\u00edcula mais penetrante e exigem um ensaio de fugas individual a cada elemento.<\/p>\n<h3>Que partes da ISO 16890 est\u00e3o em vigor?<\/h3>\n<p>A ISO 16890-1:2016, para o sistema de classifica\u00e7\u00e3o; a ISO 16890-2:2022, para a efici\u00eancia fracional e a resist\u00eancia ao escoamento do ar; a ISO 16890-3:2024, para a efici\u00eancia gravim\u00e9trica e a capacidade de reten\u00e7\u00e3o de poeiras; e a ISO 16890-4:2022, para o m\u00e9todo de condicionamento com isopropanol.<\/p>\n<h3>Como verificar a classifica\u00e7\u00e3o ISO 16890 declarada por um fornecedor?<\/h3>\n<p>Pe\u00e7a o relat\u00f3rio de ensaio do modelo e da dimens\u00e3o exatos do filtro em causa. O relat\u00f3rio deve indicar as efici\u00eancias ePM<sub>x<\/sub> iniciais e ap\u00f3s descarga, a perda de carga inicial ao caudal nominal, a perda de carga final de ensaio e o laborat\u00f3rio que realizou o ensaio.<\/p>\n<h2>Ensaios na Ulpatek<\/h2>\n<p>A Ulpatek ensaia os filtros no seu pr\u00f3prio laborat\u00f3rio, o ULPALAB, equipado com um sistema de ensaio ISO 16890, um sistema de teste de varrimento de filtros HEPA e ULPA segundo a EN 1822 \/ ISO 29463, um sistema de ensaio de desempenho e um sistema de ensaio de meios filtrantes. A Ulpatek tem certifica\u00e7\u00e3o Eurovent e produz segundo a ISO 16890 e a ISO 29463 (EN 1822).<\/p>\n<p>Se precisar do relat\u00f3rio de ensaio de uma classe de filtro, dimens\u00e3o ou caudal de ar espec\u00edficos, contacte-nos atrav\u00e9s de <a href=\"mailto:info@ulpatek.com\">info@ulpatek.com<\/a>.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Resposta curta A ISO 16890 \u00e9 a norma internacional em vigor para os filtros de ar utilizados em ventila\u00e7\u00e3o geral. Substituiu a EN 779:2012, que foi cancelada em toda a&hellip; <a class=\"read-more-link\" href=\"https:\/\/www.ulpatek.com\/pt-pt\/tecnologia-de-filtracao\/comparacao-de-normas-de-filtros\/\">Read more<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":11096,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_exactmetrics_skip_tracking":false,"footnotes":""},"class_list":["post-14378","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/pt-pt\/wp-json\/wp\/v2\/pages\/14378","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/pt-pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ulpatek.com\/pt-pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/pt-pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/pt-pt\/wp-json\/wp\/v2\/comments?post=14378"}],"version-history":[{"count":0,"href":"https:\/\/www.ulpatek.com\/pt-pt\/wp-json\/wp\/v2\/pages\/14378\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/pt-pt\/wp-json\/wp\/v2\/pages\/11096"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/pt-pt\/wp-json\/wp\/v2\/media?parent=14378"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}