{"id":14320,"date":"2026-09-23T12:48:38","date_gmt":"2026-09-23T09:48:38","guid":{"rendered":"https:\/\/www.ulpatek.com\/technologie-de-filtration\/comparatif-des-normes-de-filtres-iso-16890-en-779-merv\/"},"modified":"2026-09-29T15:58:19","modified_gmt":"2026-09-29T12:58:19","slug":"comparatif-des-normes-de-filtres-iso-16890-en-779-merv","status":"publish","type":"page","link":"https:\/\/www.ulpatek.com\/fr\/technologie-de-filtration\/comparatif-des-normes-de-filtres-iso-16890-en-779-merv\/","title":{"rendered":"Comparatif des normes de filtres\u00a0: ISO 16890, EN 779 et MERV"},"content":{"rendered":"<style>\n.ulp-doc{font-size:16px;line-height:1.65}\n.ulp-doc h2{margin:38px 0 14px;font-size:26px;line-height:1.3}\n.ulp-doc h3{margin:26px 0 10px;font-size:19px;line-height:1.35}\n.ulp-doc p{margin:0 0 16px}\n.ulp-doc ul{margin:0 0 20px 20px}\n.ulp-doc li{margin:0 0 8px}\n.ulp-doc .tbl{overflow-x:auto;margin:0 0 28px;-webkit-overflow-scrolling:touch}\n.ulp-doc table{width:100%;border-collapse:collapse;font-size:15px;min-width:520px}\n.ulp-doc th,.ulp-doc td{border:1px solid #d8dde0;padding:9px 11px;vertical-align:top;text-align:left}\n.ulp-doc th{background:#eef3f6;font-weight:600}\n.ulp-doc tbody tr:nth-child(even){background:#fafbfc}\n.ulp-doc .lead{font-size:17px;background:#f4f8fa;border-left:4px solid #1f4e79;padding:16px 18px;margin:0 0 24px}\n<\/style>\n<div class=\"ulp-doc\">\n<h2>En bref<\/h2>\n<p class=\"lead\"><strong>L\u2019ISO 16890 est la norme internationale en vigueur pour les filtres \u00e0 air de ventilation g\u00e9n\u00e9rale. Elle a remplac\u00e9 l\u2019EN 779:2012, annul\u00e9e dans toute l\u2019Europe le 30 juin 2018. Il n\u2019existe pas de conversion exacte, terme \u00e0 terme, entre les deux\u00a0: un filtre F7 n\u2019est pas \u00ab\u00a0\u00e9gal\u00a0\u00bb \u00e0 une classe ISO 16890 pr\u00e9cise, il correspond seulement \u00e0 une plage de classes possibles.<\/strong> L\u2019ISO 16890 classe un filtre selon la part des particules en suspension qu\u2019il \u00e9limine &ndash; ePM<sub>1<\/sub>, ePM<sub>2,5<\/sub>, ePM<sub>10<\/sub> ou ISO Coarse &ndash; et non selon son efficacit\u00e9 pour une seule taille de particule, 0,4\u00a0&micro;m. Le MERV (ANSI\/ASHRAE 52.2) reste un syst\u00e8me nord-am\u00e9ricain distinct, qui n\u2019a pas non plus d\u2019\u00e9quivalence exacte avec l\u2019une ou l\u2019autre de ces normes.<\/p>\n<h3>Les points cl\u00e9s<\/h3>\n<ul>\n<li><strong>Norme en vigueur\u00a0:<\/strong> EN ISO 16890, en quatre parties &ndash; partie 1 (classification) ISO 16890-1:2016, partie 2 (efficacit\u00e9 spectrale et r\u00e9sistance \u00e0 l\u2019\u00e9coulement de l\u2019air) ISO 16890-2:2022, partie 3 (efficacit\u00e9 gravim\u00e9trique et capacit\u00e9 de r\u00e9tention de poussi\u00e8re) ISO 16890-3:2024, partie 4 (conditionnement \u00e0 l\u2019isopropanol) ISO 16890-4:2022.<\/li>\n<li><strong>Norme annul\u00e9e\u00a0:<\/strong> EN 779:2012 &ndash; classes G1&ndash;G4, M5&ndash;M6, F7&ndash;F9. Elle n\u2019est plus valable pour classer de nouveaux produits dans les pays membres du CEN.<\/li>\n<li><strong>Au-del\u00e0 de l\u2019ISO 16890\u00a0:<\/strong> les filtres EPA, HEPA et ULPA n\u2019entrent pas dans le champ de l\u2019ISO 16890. Ils sont class\u00e9s selon l\u2019EN 1822 (E10&ndash;U17) et l\u2019ISO 29463 (ISO 15 E &ndash; ISO 75 U).<\/li>\n<li><strong>Am\u00e9rique du Nord\u00a0:<\/strong> MERV 1&ndash;16 selon l\u2019ANSI\/ASHRAE 52.2. Les valeurs MERV 17&ndash;20 figurent dans certaines publications, mais sortent du domaine d\u2019application de la m\u00e9thode d\u2019essai 52.2.<\/li>\n<li><strong>Conversion\u00a0:<\/strong> il n\u2019existe que des plages indicatives. Demandez toujours le rapport d\u2019essai ISO 16890 du filtre concern\u00e9.<\/li>\n<\/ul>\n<h2>Pourquoi l\u2019EN 779 a \u00e9t\u00e9 remplac\u00e9e<\/h2>\n<p>L\u2019EN 779:2012 \u00e9valuait un filtre d\u2019apr\u00e8s son efficacit\u00e9 moyenne pour une seule taille de particule &ndash; 0,4\u00a0&micro;m &ndash;, mesur\u00e9e pendant le colmatage du filtre par une poussi\u00e8re synth\u00e9tique. Cette valeur en disait tr\u00e8s peu sur l\u2019effet r\u00e9el du filtre vis-\u00e0-vis des poussi\u00e8res que nous respirons.<\/p>\n<p>L\u2019ISO 16890 mesure l\u2019efficacit\u00e9 spectrale sur toute la plage 0,3&ndash;10\u00a0&micro;m, puis pond\u00e8re le r\u00e9sultat par les distributions granulom\u00e9triques r\u00e9elles de l\u2019air ext\u00e9rieur urbain et rural. On obtient ainsi la part de PM<sub>1<\/sub>, PM<sub>2,5<\/sub> ou PM<sub>10<\/sub> que le filtre \u00e9limine &ndash; les m\u00eames fractions de particules en suspension que celles qu\u2019utilisent l\u2019Organisation mondiale de la sant\u00e9 et la r\u00e9glementation sur la qualit\u00e9 de l\u2019air. Le prescripteur peut donc relier directement une classe de filtre \u00e0 un objectif de qualit\u00e9 de l\u2019air int\u00e9rieur.<\/p>\n<h3>Les principales diff\u00e9rences<\/h3>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>&nbsp;<\/th>\n<th>EN 779:2012 (annul\u00e9e)<\/th>\n<th>EN ISO 16890<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Taille de particule \u00e9valu\u00e9e<\/td>\n<td>0,4\u00a0&micro;m uniquement<\/td>\n<td>0,3\u00a0&micro;m &ndash; 10\u00a0&micro;m<\/td>\n<\/tr>\n<tr>\n<td>Classes<\/td>\n<td>G1&ndash;G4, M5&ndash;M6, F7&ndash;F9<\/td>\n<td>ISO Coarse, ISO ePM<sub>10<\/sub>, ISO ePM<sub>2,5<\/sub>, ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>Charge \u00e9lectrostatique<\/td>\n<td>\u00c9chantillon de m\u00e9dia d\u00e9charg\u00e9 (efficacit\u00e9 minimale)<\/td>\n<td>\u00c9l\u00e9ment filtrant complet conditionn\u00e9 en vapeur d\u2019isopropanol<\/td>\n<\/tr>\n<tr>\n<td>Poussi\u00e8re de colmatage<\/td>\n<td>Poussi\u00e8re synth\u00e9tique ASHRAE<\/td>\n<td>Poussi\u00e8re d\u2019essai ISO A2 Fine<\/td>\n<\/tr>\n<tr>\n<td>Perte de charge finale d\u2019essai<\/td>\n<td>Classes G\u00a0: 250\u00a0Pa\u00a0; classes M et F\u00a0: 450\u00a0Pa<\/td>\n<td>ISO Coarse \/ ePM<sub>10<\/sub> &lt; 50\u00a0%\u00a0: 200\u00a0Pa\u00a0; ePM<sub>x<\/sub> &ge; 50\u00a0%\u00a0: 300\u00a0Pa<\/td>\n<\/tr>\n<tr>\n<td>Port\u00e9e g\u00e9ographique<\/td>\n<td>Europe (CEN)<\/td>\n<td>Internationale (ISO)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Comment une classe ISO 16890 est attribu\u00e9e<\/h2>\n<p>Le filtre est rang\u00e9 dans le groupe le plus \u00e9lev\u00e9 dont il satisfait l\u2019exigence, et l\u2019efficacit\u00e9 d\u00e9clar\u00e9e est arrondie <em>par d\u00e9faut<\/em> au multiple de 5\u00a0% le plus proche.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Groupe<\/th>\n<th>Exigence<\/th>\n<th>Classement d\u00e9clar\u00e9<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<td>ePM<sub>1<\/sub> initiale &ge; 50\u00a0% <em>et<\/em> ePM<sub>1,min<\/sub> apr\u00e8s d\u00e9charge &ge; 50\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<td>ePM<sub>2,5<\/sub> initiale &ge; 50\u00a0% <em>et<\/em> ePM<sub>2,5,min<\/sub> apr\u00e8s d\u00e9charge &ge; 50\u00a0%<\/td>\n<td>ISO ePM<sub>2,5<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<td>ePM<sub>10<\/sub> initiale &ge; 50\u00a0% (aucune exigence apr\u00e8s d\u00e9charge)<\/td>\n<td>ISO ePM<sub>10<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO Coarse<\/td>\n<td>ePM<sub>10<\/sub> &lt; 50\u00a0%<\/td>\n<td>ISO Coarse 5% &hellip; 95% (arrestance gravim\u00e9trique)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Exemple chiffr\u00e9.<\/strong> Un filtre V-Compact autrefois class\u00e9 F8 selon l\u2019EN 779 est essay\u00e9 selon l\u2019ISO 16890\u00a0: il obtient 73\u00a0% en ePM<sub>1<\/sub>, 80\u00a0% en ePM<sub>2,5<\/sub> et 93\u00a0% en ePM<sub>10<\/sub>. Comme il satisfait l\u2019exigence ePM<sub>1<\/sub>, il est class\u00e9 dans le groupe le plus \u00e9lev\u00e9 auquel il peut pr\u00e9tendre, et la valeur est arrondie par d\u00e9faut, par pas de 5\u00a0%\u00a0: <strong>ISO ePM<sub>1<\/sub> 70%<\/strong>.<\/p>\n<p>Le \u00ab\u00a0e\u00a0\u00bb d\u00e9signe l\u2019efficacit\u00e9\u00a0; l\u2019indice pr\u00e9cise la fraction de particules en suspension. ISO ePM<sub>1<\/sub> 70% signifie que le filtre \u00e9limine 70\u00a0% des particules PM<sub>1<\/sub>.<\/p>\n<h2>De l\u2019EN 779 \u00e0 l\u2019ISO 16890\u00a0: des plages indicatives, pas des \u00e9quivalences<\/h2>\n<p>Une m\u00eame classe EN 779 peut aboutir \u00e0 plusieurs classes ISO 16890 diff\u00e9rentes selon le m\u00e9dia employ\u00e9. Deux filtres portant tous deux l\u2019\u00e9tiquette F7 peuvent \u00eatre class\u00e9s \u00e0 l\u2019essai, l\u2019un ISO ePM<sub>1<\/sub> 50%, l\u2019autre ISO ePM<sub>2,5<\/sub> 65%. L\u2019\u00e9cart est le plus marqu\u00e9 avec les m\u00e9dias synth\u00e9tiques \u00e9lectrets, dont l\u2019efficacit\u00e9 chute d\u00e8s que la charge \u00e9lectrostatique est neutralis\u00e9e &ndash; c\u2019est pr\u00e9cis\u00e9ment ce que r\u00e9v\u00e8le l\u2019\u00e9tape de conditionnement de l\u2019ISO 16890.<\/p>\n<p>Le tableau ci-dessous donne la plage des efficacit\u00e9s moyennes mesur\u00e9es qu\u2019obtiennent habituellement les filtres de chaque ancienne classe EN 779 lorsqu\u2019ils sont r\u00e9essay\u00e9s selon l\u2019ISO 16890. <strong>Servez-vous-en pour restreindre une pr\u00e9s\u00e9lection, jamais pour remplacer le rapport d\u2019essai.<\/strong><\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Classe EN 779:2012<\/th>\n<th>ePM<sub>1<\/sub><\/th>\n<th>ePM<sub>2,5<\/sub><\/th>\n<th>ePM<sub>10<\/sub><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>M5<\/td>\n<td>5\u00a0% &ndash; 35\u00a0%<\/td>\n<td>10\u00a0% &ndash; 40\u00a0%<\/td>\n<td>40\u00a0% &ndash; 70\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>M6<\/td>\n<td>10\u00a0% &ndash; 40\u00a0%<\/td>\n<td>20\u00a0% &ndash; 50\u00a0%<\/td>\n<td>60\u00a0% &ndash; 80\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>F7<\/td>\n<td>40\u00a0% &ndash; 65\u00a0%<\/td>\n<td>65\u00a0% &ndash; 75\u00a0%<\/td>\n<td>80\u00a0% &ndash; 90\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>F8<\/td>\n<td>65\u00a0% &ndash; 90\u00a0%<\/td>\n<td>75\u00a0% &ndash; 95\u00a0%<\/td>\n<td>90\u00a0% &ndash; 100\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>F9<\/td>\n<td>80\u00a0% &ndash; 90\u00a0%<\/td>\n<td>85\u00a0% &ndash; 95\u00a0%<\/td>\n<td>90\u00a0% &ndash; 100\u00a0%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Les filtres G1&ndash;G4 rel\u00e8vent du groupe ISO Coarse. Leur valeur ISO Coarse est une arrestance gravim\u00e9trique\u00a0: elle n\u2019est pas comparable \u00e0 une efficacit\u00e9 ePM<sub>x<\/sub>.<\/p>\n<h2>Comparaison avec le MERV (ANSI\/ASHRAE 52.2)<\/h2>\n<p>Le MERV est d\u00e9termin\u00e9 \u00e0 partir de l\u2019efficacit\u00e9 moyenne composite par taille de particule, dans trois plages\u00a0: E1 = 0,30&ndash;1,0\u00a0&micro;m, E2 = 1,0&ndash;3,0\u00a0&micro;m, E3 = 3,0&ndash;10,0\u00a0&micro;m. Le filtre re\u00e7oit le MERV le plus \u00e9lev\u00e9 dont il satisfait <em>toutes<\/em> les exigences.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>MERV<\/th>\n<th>E1 (0,30&ndash;1,0\u00a0&micro;m)<\/th>\n<th>E2 (1,0&ndash;3,0\u00a0&micro;m)<\/th>\n<th>E3 (3,0&ndash;10,0\u00a0&micro;m)<\/th>\n<th>Groupe ISO 16890 indicatif<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1&ndash;4<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&lt; 20\u00a0%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 20\u00a0%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 35\u00a0%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 50\u00a0%<\/td>\n<td>ISO Coarse &ndash; ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 20\u00a0%<\/td>\n<td>&ge; 70\u00a0%<\/td>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 35\u00a0%<\/td>\n<td>&ge; 75\u00a0%<\/td>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 50\u00a0%<\/td>\n<td>&ge; 80\u00a0%<\/td>\n<td>ISO ePM<sub>10<\/sub> &ndash; ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>&ge; 20\u00a0%<\/td>\n<td>&ge; 65\u00a0%<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>&ge; 35\u00a0%<\/td>\n<td>&ge; 80\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>&ge; 50\u00a0%<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>&ge; 75\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>La derni\u00e8re colonne ne donne qu\u2019une orientation approximative. Le MERV utilise un autre a\u00e9rosol, d\u2019autres bandes granulom\u00e9triques et aucun conditionnement \u00e0 l\u2019isopropanol\u00a0: un filtre MERV 13 et un filtre ISO ePM<sub>1<\/sub> 50% ne sont donc pas interchangeables, par d\u00e9finition.<\/p>\n<h2>L\u00e0 o\u00f9 s\u2019arr\u00eate l\u2019ISO 16890\u00a0: EPA, HEPA et ULPA<\/h2>\n<p>L\u2019ISO 16890 couvre les filtres jusqu\u2019\u00e0 environ ISO ePM<sub>1<\/sub> 95%. Au-del\u00e0, les filtres sont essay\u00e9s par comptage de particules \u00e0 la taille de particule la plus p\u00e9n\u00e9trante (MPPS), selon la NF EN 1822 ou l\u2019ISO 29463, et chaque \u00e9l\u00e9ment subit individuellement un essai d\u2019\u00e9tanch\u00e9it\u00e9.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Classe EN 1822<\/th>\n<th>Efficacit\u00e9 globale \u00e0 la MPPS<\/th>\n<th>Efficacit\u00e9 locale<\/th>\n<th>Classe ISO 29463<\/th>\n<th>Groupe<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>E10<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>&ndash;<\/td>\n<td>pas d\u2019\u00e9quivalent<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>E11<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>&ndash;<\/td>\n<td>ISO 15 E<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>E12<\/td>\n<td>&ge; 99,5\u00a0%<\/td>\n<td>&ndash;<\/td>\n<td>ISO 25 E<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>H13<\/td>\n<td>&ge; 99,95\u00a0%<\/td>\n<td>&ge; 99,75\u00a0%<\/td>\n<td>ISO 35 H<\/td>\n<td>HEPA<\/td>\n<\/tr>\n<tr>\n<td>H14<\/td>\n<td>&ge; 99,995\u00a0%<\/td>\n<td>&ge; 99,975\u00a0%<\/td>\n<td>ISO 45 H<\/td>\n<td>HEPA<\/td>\n<\/tr>\n<tr>\n<td>U15<\/td>\n<td>&ge; 99,9995\u00a0%<\/td>\n<td>&ge; 99,9975\u00a0%<\/td>\n<td>ISO 55 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<tr>\n<td>U16<\/td>\n<td>&ge; 99,99995\u00a0%<\/td>\n<td>&ge; 99,99975\u00a0%<\/td>\n<td>ISO 65 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<tr>\n<td>U17<\/td>\n<td>&ge; 99,999995\u00a0%<\/td>\n<td>&ge; 99,9999\u00a0%<\/td>\n<td>ISO 75 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>L\u2019ISO 29463 commence \u00e0 la classe ISO 15 E\u00a0: la classe E10 de l\u2019EN 1822 n\u2019a donc pas de correspondant dans l\u2019ISO 29463. Son \u00e9quivalent le plus proche dans l\u2019ISO 16890 est ISO ePM<sub>1<\/sub> &gt; 95%.<\/p>\n<h2>Choisir une classe pour un projet<\/h2>\n<p>Partez de la qualit\u00e9 de l\u2019air ext\u00e9rieur sur le site et de la qualit\u00e9 de l\u2019air int\u00e9rieur \u00e0 assurer, et non de l\u2019\u00e9tiquette de l\u2019ancien filtre.<\/p>\n<ul>\n<li><strong>Pr\u00e9filtration et protection des \u00e9quipements\u00a0:<\/strong> ISO Coarse ou ISO ePM<sub>10<\/sub>. Prot\u00e8ge les batteries, les ventilateurs et les filtres situ\u00e9s en aval contre les peluches, les insectes et le sable.<\/li>\n<li><strong>Ventilation g\u00e9n\u00e9rale des b\u00e2timents tertiaires\u00a0:<\/strong> ISO ePM<sub>1<\/sub> 50&ndash;60% remplace habituellement ce que l\u2019on prescrivait autrefois en F7.<\/li>\n<li><strong>Bureaux et \u00e9tablissements scolaires en air urbain pollu\u00e9\u00a0:<\/strong> ISO ePM<sub>1<\/sub> 70&ndash;80%.<\/li>\n<li><strong>H\u00f4pitaux, production pharmaceutique et agroalimentaire\u00a0:<\/strong> ISO ePM<sub>1<\/sub> 80% ou plus, en dernier \u00e9tage avant un filtre HEPA.<\/li>\n<li><strong>Salles propres et confinement\u00a0:<\/strong> H13, H14 ou plus selon l\u2019EN 1822 \/ l\u2019ISO 29463, choisis en m\u00eame temps que la classe de la salle propre selon l\u2019ISO 14644-1.<\/li>\n<\/ul>\n<p>La recommandation Eurovent REC 4\/23 oriente le choix de la classe de filtre en fonction de la qualit\u00e9 de l\u2019air ext\u00e9rieur sur le site d\u2019installation et de la qualit\u00e9 de l\u2019air int\u00e9rieur vis\u00e9e. C\u2019est la r\u00e9f\u00e9rence que suivent aujourd\u2019hui la plupart des cahiers des charges europ\u00e9ens.<\/p>\n<h2>Questions fr\u00e9quentes<\/h2>\n<h3>L\u2019EN 779 est-elle encore valable\u00a0?<\/h3>\n<p>Non. L\u2019EN 779:2012 a \u00e9t\u00e9 annul\u00e9e le 30 juin 2018 et remplac\u00e9e par l\u2019EN ISO 16890. Sur le march\u00e9, les filtres peuvent encore \u00eatre d\u00e9sign\u00e9s de fa\u00e7on informelle par \u00ab\u00a0F7\u00a0\u00bb ou \u00ab\u00a0M5\u00a0\u00bb, mais un filtre neuf devrait \u00eatre prescrit, essay\u00e9 et document\u00e9 selon l\u2019ISO 16890.<\/p>\n<h3>Quel est l\u2019\u00e9quivalent ISO 16890 d\u2019un filtre F7\u00a0?<\/h3>\n<p>Il n\u2019existe pas d\u2019\u00e9quivalent unique. \u00c0 l\u2019essai, les filtres qui \u00e9taient class\u00e9s F7 obtiennent g\u00e9n\u00e9ralement 40&ndash;65\u00a0% en ePM<sub>1<\/sub>, 65&ndash;75\u00a0% en ePM<sub>2,5<\/sub> et 80&ndash;90\u00a0% en ePM<sub>10<\/sub>. En pratique, ISO ePM<sub>1<\/sub> 50&ndash;60% est le remplacement le plus courant, mais pour un filtre donn\u00e9, seul son rapport d\u2019essai permet de r\u00e9pondre avec certitude.<\/p>\n<h3>Que signifie ISO ePM1 70%\u00a0?<\/h3>\n<p>Cela signifie que le filtre \u00e9limine 70\u00a0% des particules en suspension d\u2019un diam\u00e8tre a\u00e9rodynamique inf\u00e9rieur ou \u00e9gal \u00e0 1\u00a0&micro;m, valeur mesur\u00e9e sur la plage 0,3&ndash;10\u00a0&micro;m et pond\u00e9r\u00e9e par une distribution granulom\u00e9trique normalis\u00e9e de l\u2019air urbain. Les valeurs d\u00e9clar\u00e9es sont arrondies par d\u00e9faut, par pas de 5\u00a0%.<\/p>\n<h3>Pourquoi l\u2019ISO 16890 d\u00e9charge-t-elle le filtre \u00e0 l\u2019isopropanol\u00a0?<\/h3>\n<p>De nombreux m\u00e9dias synth\u00e9tiques captent les particules gr\u00e2ce \u00e0 une charge \u00e9lectrostatique. Cette charge se dissipe en service\u00a0: l\u2019efficacit\u00e9 initiale surestime donc les performances r\u00e9elles. L\u2019ISO 16890-4 conditionne l\u2019\u00e9l\u00e9ment filtrant complet dans une vapeur d\u2019isopropanol satur\u00e9e, puis l\u2019essai est r\u00e9p\u00e9t\u00e9\u00a0; la classe traduit ainsi une efficacit\u00e9 qui ne d\u00e9pend pas de la charge.<\/p>\n<h3>Un filtre MERV 13 \u00e9quivaut-il \u00e0 un filtre ISO ePM1 50%\u00a0?<\/h3>\n<p>Ils sont globalement comparables \u00e0 l\u2019usage, mais pas \u00e9quivalents par d\u00e9finition. Les deux normes utilisent des a\u00e9rosols d\u2019essai, des bandes granulom\u00e9triques et des conditionnements diff\u00e9rents. Un filtre devrait porter la classification de la norme cit\u00e9e dans le cahier des charges, et non une valeur convertie.<\/p>\n<h3>L\u2019ISO 16890 couvre-t-elle les filtres HEPA\u00a0?<\/h3>\n<p>Non. L\u2019ISO 16890 s\u2019arr\u00eate \u00e0 environ ISO ePM<sub>1<\/sub> 95%. Les filtres EPA, HEPA et ULPA sont class\u00e9s selon l\u2019EN 1822 ou l\u2019ISO 29463, qui les essaient \u00e0 la taille de particule la plus p\u00e9n\u00e9trante et exigent un essai d\u2019\u00e9tanch\u00e9it\u00e9 individuel sur chaque \u00e9l\u00e9ment.<\/p>\n<h3>Quelles parties de l\u2019ISO 16890 sont en vigueur\u00a0?<\/h3>\n<p>L\u2019ISO 16890-1:2016 pour le syst\u00e8me de classification, l\u2019ISO 16890-2:2022 pour l\u2019efficacit\u00e9 spectrale et la r\u00e9sistance \u00e0 l\u2019\u00e9coulement de l\u2019air, l\u2019ISO 16890-3:2024 pour l\u2019efficacit\u00e9 gravim\u00e9trique et la capacit\u00e9 de r\u00e9tention de poussi\u00e8re, et l\u2019ISO 16890-4:2022 pour la m\u00e9thode de conditionnement \u00e0 l\u2019isopropanol.<\/p>\n<h3>Comment v\u00e9rifier la classe ISO 16890 annonc\u00e9e par un fournisseur\u00a0?<\/h3>\n<p>Demandez le rapport d\u2019essai du mod\u00e8le de filtre concern\u00e9, dans la dimension exacte. Il devrait indiquer les efficacit\u00e9s ePM<sub>x<\/sub> initiale et apr\u00e8s d\u00e9charge, la perte de charge initiale au d\u00e9bit nominal, la perte de charge finale d\u2019essai et le laboratoire qui a r\u00e9alis\u00e9 l\u2019essai.<\/p>\n<h2>Les essais chez Ulpatek<\/h2>\n<p>Ulpatek essaie ses filtres dans son propre laboratoire, ULPALAB, \u00e9quip\u00e9 d\u2019un banc d\u2019essai ISO 16890, d\u2019un banc d\u2019essai par balayage EN 1822 \/ ISO 29463 pour filtres HEPA et ULPA, d\u2019un banc d\u2019essai de performance et d\u2019un banc d\u2019essai pour m\u00e9dias filtrants. Ulpatek est certifi\u00e9 Eurovent et fabrique selon l\u2019ISO 16890 et l\u2019ISO 29463 (EN 1822).<\/p>\n<p>Si vous avez besoin du rapport d\u2019essai pour une classe de filtre, une dimension ou un d\u00e9bit d\u2019air pr\u00e9cis, \u00e9crivez-nous \u00e0 <a href=\"mailto:info@ulpatek.com\">info@ulpatek.com<\/a>.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>En bref L\u2019ISO 16890 est la norme internationale en vigueur pour les filtres \u00e0 air de ventilation g\u00e9n\u00e9rale. Elle a remplac\u00e9 l\u2019EN 779:2012, annul\u00e9e dans toute l\u2019Europe le 30 juin&hellip; <a class=\"read-more-link\" href=\"https:\/\/www.ulpatek.com\/fr\/technologie-de-filtration\/comparatif-des-normes-de-filtres-iso-16890-en-779-merv\/\">Read more<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":11060,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_exactmetrics_skip_tracking":false,"footnotes":""},"class_list":["post-14320","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/fr\/wp-json\/wp\/v2\/pages\/14320","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ulpatek.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/fr\/wp-json\/wp\/v2\/comments?post=14320"}],"version-history":[{"count":0,"href":"https:\/\/www.ulpatek.com\/fr\/wp-json\/wp\/v2\/pages\/14320\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/fr\/wp-json\/wp\/v2\/pages\/11060"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/fr\/wp-json\/wp\/v2\/media?parent=14320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}