{"id":14349,"date":"2026-09-23T12:49:18","date_gmt":"2026-09-23T09:49:18","guid":{"rendered":"https:\/\/www.ulpatek.com\/tecnologia-de-filtracion\/comparacion-de-normas-de-filtros-iso-16890-en-779-merv\/"},"modified":"2026-09-29T15:58:21","modified_gmt":"2026-09-29T12:58:21","slug":"comparacion-de-normas-de-filtros-iso-16890-en-779-merv","status":"publish","type":"page","link":"https:\/\/www.ulpatek.com\/es\/tecnologia-de-filtracion\/comparacion-de-normas-de-filtros-iso-16890-en-779-merv\/","title":{"rendered":"Comparaci\u00f3n de normas de filtros: ISO 16890, EN 779 y MERV"},"content":{"rendered":"<style>\n.ulp-doc{font-size:16px;line-height:1.65}\n.ulp-doc h2{margin:38px 0 14px;font-size:26px;line-height:1.3}\n.ulp-doc h3{margin:26px 0 10px;font-size:19px;line-height:1.35}\n.ulp-doc p{margin:0 0 16px}\n.ulp-doc ul{margin:0 0 20px 20px}\n.ulp-doc li{margin:0 0 8px}\n.ulp-doc .tbl{overflow-x:auto;margin:0 0 28px;-webkit-overflow-scrolling:touch}\n.ulp-doc table{width:100%;border-collapse:collapse;font-size:15px;min-width:520px}\n.ulp-doc th,.ulp-doc td{border:1px solid #d8dde0;padding:9px 11px;vertical-align:top;text-align:left}\n.ulp-doc th{background:#eef3f6;font-weight:600}\n.ulp-doc tbody tr:nth-child(even){background:#fafbfc}\n.ulp-doc .lead{font-size:17px;background:#f4f8fa;border-left:4px solid #1f4e79;padding:16px 18px;margin:0 0 24px}\n<\/style>\n<div class=\"ulp-doc\">\n<h2>Respuesta breve<\/h2>\n<p class=\"lead\"><strong>La ISO 16890 es la norma internacional vigente para los filtros de aire utilizados en ventilaci\u00f3n general. Sustituy\u00f3 a la EN 779:2012, anulada en toda Europa el 30 de junio de 2018. No existe una conversi\u00f3n exacta, de uno a uno, entre ambas: un filtro F7 no \u00abequivale\u00bb a una clase ISO 16890 concreta, sino a un intervalo de clases posibles.<\/strong> La ISO 16890 clasifica el filtro seg\u00fan la proporci\u00f3n de la materia particulada del aire que retiene (ePM<sub>1<\/sub>, ePM<sub>2,5<\/sub>, ePM<sub>10<\/sub> o ISO Coarse), y no seg\u00fan su eficiencia frente a un \u00fanico tama\u00f1o de part\u00edcula de 0,4\u00a0&micro;m. El sistema MERV (ANSI\/ASHRAE 52.2) sigue siendo un sistema norteamericano independiente y tampoco tiene equivalencia exacta con ninguna de las dos.<\/p>\n<h3>Datos clave<\/h3>\n<ul>\n<li><strong>Norma vigente:<\/strong> UNE-EN ISO 16890, en cuatro partes: parte 1 (clasificaci\u00f3n), ISO 16890-1:2016; parte 2 (eficiencia fraccional y resistencia al flujo de aire), ISO 16890-2:2022; parte 3 (eficiencia gravim\u00e9trica y capacidad de retenci\u00f3n de polvo), ISO 16890-3:2024; y parte 4 (acondicionamiento con isopropanol), ISO 16890-4:2022.<\/li>\n<li><strong>Norma anulada:<\/strong> EN 779:2012, clases G1&ndash;G4, M5&ndash;M6 y F7&ndash;F9. Ya no es v\u00e1lida para clasificar productos nuevos en los pa\u00edses miembros del CEN.<\/li>\n<li><strong>Por encima de la ISO 16890:<\/strong> Los filtros absolutos (EPA, HEPA y ULPA) quedan fuera del alcance de la ISO 16890. Se clasifican seg\u00fan la EN 1822 (E10&ndash;U17) y la ISO 29463 (de ISO 15 E a ISO 75 U).<\/li>\n<li><strong>Norteam\u00e9rica:<\/strong> MERV 1&ndash;16 seg\u00fan ANSI\/ASHRAE 52.2. Los valores MERV 17&ndash;20 aparecen en algunas publicaciones, pero quedan fuera del alcance del m\u00e9todo de ensayo de la 52.2.<\/li>\n<li><strong>Conversi\u00f3n:<\/strong> Solo existen intervalos orientativos. Pida siempre el informe de ensayo ISO 16890 del filtro concreto.<\/li>\n<\/ul>\n<h2>Por qu\u00e9 se sustituy\u00f3 la EN 779<\/h2>\n<p>La EN 779:2012 clasificaba el filtro seg\u00fan su eficiencia media frente a part\u00edculas de un solo tama\u00f1o, 0,4\u00a0&micro;m, medida mientras el filtro se cargaba con polvo sint\u00e9tico. Ese valor dec\u00eda muy poco de lo que el filtro hace realmente con el polvo que respiran las personas.<\/p>\n<p>La ISO 16890 mide la eficiencia fraccional en todo el intervalo de 0,3 a 10\u00a0&micro;m y despu\u00e9s pondera el resultado con las distribuciones reales de tama\u00f1os de part\u00edcula del aire exterior urbano y rural. El resultado es la proporci\u00f3n de PM<sub>1<\/sub>, PM<sub>2,5<\/sub> o PM<sub>10<\/sub> que el filtro retiene: las mismas fracciones de materia particulada que utilizan la Organizaci\u00f3n Mundial de la Salud y la legislaci\u00f3n sobre calidad del aire. As\u00ed, el prescriptor puede relacionar directamente una clase de filtro con un objetivo de calidad del aire interior.<\/p>\n<h3>Principales diferencias<\/h3>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>&nbsp;<\/th>\n<th>EN 779:2012 (anulada)<\/th>\n<th>EN ISO 16890<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tama\u00f1o de part\u00edcula evaluado<\/td>\n<td>Solo 0,4\u00a0&micro;m<\/td>\n<td>0,3\u00a0&micro;m &ndash; 10\u00a0&micro;m<\/td>\n<\/tr>\n<tr>\n<td>Clases<\/td>\n<td>G1&ndash;G4, M5&ndash;M6, F7&ndash;F9<\/td>\n<td>ISO Coarse, ISO ePM<sub>10<\/sub>, ISO ePM<sub>2,5<\/sub>, ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>Carga electrost\u00e1tica<\/td>\n<td>Muestra de medio filtrante descargada (eficiencia m\u00ednima)<\/td>\n<td>Elemento filtrante completo acondicionado en vapor de isopropanol<\/td>\n<\/tr>\n<tr>\n<td>Polvo de carga<\/td>\n<td>Polvo sint\u00e9tico ASHRAE<\/td>\n<td>Polvo de ensayo ISO A2 Fine<\/td>\n<\/tr>\n<tr>\n<td>P\u00e9rdida de carga final de ensayo<\/td>\n<td>Clases G: 250\u00a0Pa; clases M y F: 450\u00a0Pa<\/td>\n<td>ISO Coarse \/ ePM<sub>10<\/sub> &lt; 50\u00a0%: 200\u00a0Pa; ePM<sub>x<\/sub> &ge; 50\u00a0%: 300\u00a0Pa<\/td>\n<\/tr>\n<tr>\n<td>\u00c1mbito geogr\u00e1fico<\/td>\n<td>Europa (CEN)<\/td>\n<td>Internacional (ISO)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>C\u00f3mo se asigna una clase ISO 16890<\/h2>\n<p>El filtro se asigna al grupo m\u00e1s alto cuyo requisito cumple, y la eficiencia declarada se redondea <em>a la baja<\/em> en pasos del 5\u00a0%.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Grupo<\/th>\n<th>Requisito<\/th>\n<th>Se declara como<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<td>ePM<sub>1<\/sub> inicial &ge; 50\u00a0% <em>y<\/em> ePM<sub>1,min<\/sub> descargada &ge; 50\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<td>ePM<sub>2,5<\/sub> inicial &ge; 50\u00a0% <em>y<\/em> ePM<sub>2,5,min<\/sub> descargada &ge; 50\u00a0%<\/td>\n<td>ISO ePM<sub>2,5<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<td>ePM<sub>10<\/sub> inicial &ge; 50\u00a0% (sin requisito de eficiencia descargada)<\/td>\n<td>ISO ePM<sub>10<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO Coarse<\/td>\n<td>ePM<sub>10<\/sub> &lt; 50\u00a0%<\/td>\n<td>ISO Coarse 5% &hellip; 95% (retenci\u00f3n gravim\u00e9trica)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Ejemplo pr\u00e1ctico.<\/strong> Un filtro V-Compact clasificado anteriormente como F8 seg\u00fan la EN 779 se ensaya conforme a la ISO 16890 y obtiene un 73\u00a0% en ePM<sub>1<\/sub>, un 80\u00a0% en ePM<sub>2,5<\/sub> y un 93\u00a0% en ePM<sub>10<\/sub>. Como cumple el requisito de ePM<sub>1<\/sub>, se clasifica en el grupo m\u00e1s alto al que puede optar y el valor se redondea a la baja en pasos del 5\u00a0%: <strong>ISO ePM<sub>1<\/sub> 70%<\/strong>.<\/p>\n<p>La \u00abe\u00bb significa eficiencia y el sub\u00edndice indica la fracci\u00f3n de materia particulada. ISO ePM<sub>1<\/sub> 70% significa que el filtro retiene el 70\u00a0% de las part\u00edculas PM<sub>1<\/sub>.<\/p>\n<h2>De la EN 779 a la ISO 16890: intervalos orientativos, no equivalencias<\/h2>\n<p>Una misma clase EN 779 puede corresponder a varias clases ISO 16890 distintas seg\u00fan el medio filtrante utilizado. Dos filtros que llevaban la misma etiqueta F7 pueden dar en el ensayo, respectivamente, ISO ePM<sub>1<\/sub> 50% e ISO ePM<sub>2,5<\/sub> 65%. El efecto es m\u00e1s acusado en los medios sint\u00e9ticos de tipo electret, cuya eficiencia disminuye en cuanto se neutraliza la carga electrost\u00e1tica, que es precisamente lo que pone de manifiesto la etapa de acondicionamiento de la ISO 16890.<\/p>\n<p>La tabla siguiente muestra el intervalo de eficiencias medias que suelen medirse en los filtros de cada antigua clase EN 779 cuando se vuelven a ensayar seg\u00fan la ISO 16890. <strong>Util\u00edcela para acotar una preselecci\u00f3n, nunca como sustituto del informe de ensayo.<\/strong><\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Clase EN 779:2012<\/th>\n<th>ePM<sub>1<\/sub><\/th>\n<th>ePM<sub>2,5<\/sub><\/th>\n<th>ePM<sub>10<\/sub><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>M5<\/td>\n<td>5\u00a0% &ndash; 35\u00a0%<\/td>\n<td>10\u00a0% &ndash; 40\u00a0%<\/td>\n<td>40\u00a0% &ndash; 70\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>M6<\/td>\n<td>10\u00a0% &ndash; 40\u00a0%<\/td>\n<td>20\u00a0% &ndash; 50\u00a0%<\/td>\n<td>60\u00a0% &ndash; 80\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>F7<\/td>\n<td>40\u00a0% &ndash; 65\u00a0%<\/td>\n<td>65\u00a0% &ndash; 75\u00a0%<\/td>\n<td>80\u00a0% &ndash; 90\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>F8<\/td>\n<td>65\u00a0% &ndash; 90\u00a0%<\/td>\n<td>75\u00a0% &ndash; 95\u00a0%<\/td>\n<td>90\u00a0% &ndash; 100\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>F9<\/td>\n<td>80\u00a0% &ndash; 90\u00a0%<\/td>\n<td>85\u00a0% &ndash; 95\u00a0%<\/td>\n<td>90\u00a0% &ndash; 100\u00a0%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Los filtros G1&ndash;G4 pertenecen al grupo ISO Coarse. Su valor ISO Coarse es una retenci\u00f3n gravim\u00e9trica y no es comparable con una eficiencia ePM<sub>x<\/sub>.<\/p>\n<h2>Comparaci\u00f3n con MERV (ANSI\/ASHRAE 52.2)<\/h2>\n<p>El valor MERV se obtiene a partir de la eficiencia media compuesta por tama\u00f1o de part\u00edcula en tres intervalos de tama\u00f1o: E1 = 0,30&ndash;1,0\u00a0&micro;m, E2 = 1,0&ndash;3,0\u00a0&micro;m y E3 = 3,0&ndash;10,0\u00a0&micro;m. El filtro recibe el MERV m\u00e1s alto del que cumple <em>todos<\/em> los requisitos.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>MERV<\/th>\n<th>E1 (0,30&ndash;1,0\u00a0&micro;m)<\/th>\n<th>E2 (1,0&ndash;3,0\u00a0&micro;m)<\/th>\n<th>E3 (3,0&ndash;10,0\u00a0&micro;m)<\/th>\n<th>Grupo ISO 16890 orientativo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1&ndash;4<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&lt; 20\u00a0%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 20\u00a0%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 35\u00a0%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 50\u00a0%<\/td>\n<td>ISO Coarse &ndash; ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 20\u00a0%<\/td>\n<td>&ge; 70\u00a0%<\/td>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 35\u00a0%<\/td>\n<td>&ge; 75\u00a0%<\/td>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 50\u00a0%<\/td>\n<td>&ge; 80\u00a0%<\/td>\n<td>ISO ePM<sub>10<\/sub> &ndash; ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>&ge; 20\u00a0%<\/td>\n<td>&ge; 65\u00a0%<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>&ge; 35\u00a0%<\/td>\n<td>&ge; 80\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>&ge; 50\u00a0%<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>&ge; 75\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>La \u00faltima columna es solo una orientaci\u00f3n aproximada. El sistema MERV utiliza otro aerosol y otras bandas de tama\u00f1o, y no incluye acondicionamiento con isopropanol, por lo que un filtro MERV 13 y un filtro ISO ePM<sub>1<\/sub> 50% no son intercambiables por definici\u00f3n.<\/p>\n<h2>D\u00f3nde termina la ISO 16890: EPA, HEPA y ULPA<\/h2>\n<p>La ISO 16890 abarca los filtros hasta aproximadamente ISO ePM<sub>1<\/sub> 95%. Por encima de ese nivel, los filtros se ensayan mediante recuento de part\u00edculas en el tama\u00f1o de part\u00edcula m\u00e1s penetrante (MPPS) seg\u00fan la EN 1822 o la ISO 29463, y cada elemento se somete individualmente a un ensayo de fugas.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Clase EN 1822<\/th>\n<th>Eficiencia global en el MPPS<\/th>\n<th>Eficiencia local<\/th>\n<th>Clase ISO 29463<\/th>\n<th>Grupo<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>E10<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>&ndash;<\/td>\n<td>Sin equivalente<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>E11<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>&ndash;<\/td>\n<td>ISO 15 E<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>E12<\/td>\n<td>&ge; 99,5\u00a0%<\/td>\n<td>&ndash;<\/td>\n<td>ISO 25 E<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>H13<\/td>\n<td>&ge; 99,95\u00a0%<\/td>\n<td>&ge; 99,75\u00a0%<\/td>\n<td>ISO 35 H<\/td>\n<td>HEPA<\/td>\n<\/tr>\n<tr>\n<td>H14<\/td>\n<td>&ge; 99,995\u00a0%<\/td>\n<td>&ge; 99,975\u00a0%<\/td>\n<td>ISO 45 H<\/td>\n<td>HEPA<\/td>\n<\/tr>\n<tr>\n<td>U15<\/td>\n<td>&ge; 99,9995\u00a0%<\/td>\n<td>&ge; 99,9975\u00a0%<\/td>\n<td>ISO 55 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<tr>\n<td>U16<\/td>\n<td>&ge; 99,99995\u00a0%<\/td>\n<td>&ge; 99,99975\u00a0%<\/td>\n<td>ISO 65 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<tr>\n<td>U17<\/td>\n<td>&ge; 99,999995\u00a0%<\/td>\n<td>&ge; 99,9999\u00a0%<\/td>\n<td>ISO 75 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>La ISO 29463 empieza en ISO 15 E, por lo que la clase E10 de la EN 1822 no tiene equivalente en la ISO 29463. Su equivalente m\u00e1s pr\u00f3ximo en la ISO 16890 es ISO ePM<sub>1<\/sub> &gt; 95%.<\/p>\n<h2>C\u00f3mo elegir la clase para un proyecto<\/h2>\n<p>Parta de la calidad del aire exterior en el emplazamiento y de la calidad del aire interior que debe conseguir, no de la etiqueta del filtro antiguo.<\/p>\n<ul>\n<li><strong>Prefiltraci\u00f3n y protecci\u00f3n de los equipos:<\/strong> ISO Coarse o ISO ePM<sub>10<\/sub>. Protege las bater\u00edas, los ventiladores y los filtros situados aguas abajo frente a pelusas, insectos y arena.<\/li>\n<li><strong>Ventilaci\u00f3n general de edificios comerciales:<\/strong> ISO ePM<sub>1<\/sub> 50&ndash;60% es la sustituci\u00f3n habitual de lo que antes se especificaba como F7.<\/li>\n<li><strong>Oficinas y centros educativos en entornos urbanos contaminados:<\/strong> ISO ePM<sub>1<\/sub> 70&ndash;80%.<\/li>\n<li><strong>Hospitales, producci\u00f3n farmac\u00e9utica y producci\u00f3n alimentaria:<\/strong> ISO ePM<sub>1<\/sub> 80% o superior como \u00faltima etapa antes de un filtro absoluto (HEPA).<\/li>\n<li><strong>Salas blancas y contenci\u00f3n:<\/strong> H13, H14 o superior seg\u00fan EN 1822 \/ ISO 29463, que se eligen junto con la clase de sala blanca seg\u00fan la ISO 14644-1.<\/li>\n<\/ul>\n<p>La recomendaci\u00f3n Eurovent REC 4\/23 orienta sobre la clase de filtro en funci\u00f3n de la calidad del aire exterior en el emplazamiento de la instalaci\u00f3n y de la calidad del aire interior que se quiere conseguir. Es la referencia que siguen hoy la mayor\u00eda de las especificaciones europeas.<\/p>\n<h2>Preguntas frecuentes<\/h2>\n<h3>\u00bfSigue siendo v\u00e1lida la EN 779?<\/h3>\n<p>No. La EN 779:2012 se anul\u00f3 el 30 de junio de 2018 y fue sustituida por la EN ISO 16890. En el mercado todav\u00eda se habla informalmente de filtros \u00abF7\u00bb o \u00abM5\u00bb, pero un filtro nuevo deber\u00eda especificarse, ensayarse y documentarse conforme a la ISO 16890.<\/p>\n<h3>\u00bfCu\u00e1l es el equivalente ISO 16890 de un filtro F7?<\/h3>\n<p>No hay un equivalente \u00fanico. Los filtros que se clasificaban como F7 suelen dar entre el 40 y el 65\u00a0% en ePM<sub>1<\/sub>, entre el 65 y el 75\u00a0% en ePM<sub>2,5<\/sub> y entre el 80 y el 90\u00a0% en ePM<sub>10<\/sub>. En la pr\u00e1ctica, ISO ePM<sub>1<\/sub> 50&ndash;60% es la sustituci\u00f3n m\u00e1s habitual, pero la respuesta correcta para un filtro concreto solo puede darla su informe de ensayo.<\/p>\n<h3>\u00bfQu\u00e9 significa ISO ePM1 70%?<\/h3>\n<p>Significa que el filtro retiene el 70\u00a0% de la materia particulada con un di\u00e1metro aerodin\u00e1mico de hasta 1\u00a0&micro;m; la eficiencia se mide en el intervalo de 0,3 a 10\u00a0&micro;m y se pondera con una distribuci\u00f3n normalizada de part\u00edculas del aire urbano. Los valores declarados se redondean a la baja en pasos del 5\u00a0%.<\/p>\n<h3>\u00bfPor qu\u00e9 la ISO 16890 descarga el filtro con isopropanol?<\/h3>\n<p>Muchos medios sint\u00e9ticos captan las part\u00edculas gracias a una carga electrost\u00e1tica. Esa carga se disipa durante el servicio, por lo que la eficiencia inicial sobrestima el rendimiento real. Seg\u00fan la ISO 16890-4, el elemento completo se acondiciona en vapor saturado de isopropanol y se repite el ensayo, de modo que la clase refleja una eficiencia que no depende de la carga.<\/p>\n<h3>\u00bfEs MERV 13 lo mismo que ISO ePM1 50%?<\/h3>\n<p>Por su aplicaci\u00f3n son comparables a grandes rasgos, pero no son equivalentes por definici\u00f3n. Las dos normas utilizan aerosoles de ensayo distintos, bandas de tama\u00f1o de part\u00edcula distintas y un acondicionamiento distinto. Un filtro deber\u00eda llevar la clasificaci\u00f3n de la norma citada en la especificaci\u00f3n, no un valor convertido.<\/p>\n<h3>\u00bfCubre la ISO 16890 los filtros HEPA?<\/h3>\n<p>No. La ISO 16890 llega aproximadamente hasta ISO ePM<sub>1<\/sub> 95%. Los filtros absolutos EPA, HEPA y ULPA se clasifican seg\u00fan la EN 1822 o la ISO 29463, que ensayan en el tama\u00f1o de part\u00edcula m\u00e1s penetrante y exigen un ensayo de fugas individual de cada elemento.<\/p>\n<h3>\u00bfQu\u00e9 partes de la ISO 16890 est\u00e1n vigentes?<\/h3>\n<p>La ISO 16890-1:2016, para el sistema de clasificaci\u00f3n; la ISO 16890-2:2022, para la eficiencia fraccional y la resistencia al flujo de aire; la ISO 16890-3:2024, para la eficiencia gravim\u00e9trica y la capacidad de retenci\u00f3n de polvo; y la ISO 16890-4:2022, para el m\u00e9todo de acondicionamiento con isopropanol.<\/p>\n<h3>\u00bfC\u00f3mo comprobar la declaraci\u00f3n ISO 16890 de un proveedor?<\/h3>\n<p>Pida el informe de ensayo de ese mismo modelo y tama\u00f1o de filtro. Deber\u00eda indicar las eficiencias ePM<sub>x<\/sub> inicial y descargada, la p\u00e9rdida de carga inicial al caudal nominal, la p\u00e9rdida de carga final de ensayo y el laboratorio que realiz\u00f3 el ensayo.<\/p>\n<h2>Ensayos en Ulpatek<\/h2>\n<p>Ulpatek ensaya sus filtros en su propio laboratorio, ULPALAB, equipado con un sistema de ensayo ISO 16890, un sistema de ensayo de fugas por barrido para filtros HEPA y ULPA seg\u00fan EN 1822 \/ ISO 29463, un sistema de ensayo de prestaciones y un sistema de ensayo de medios filtrantes. Ulpatek cuenta con la certificaci\u00f3n Eurovent y fabrica conforme a las normas ISO 16890 e ISO 29463 (EN 1822).<\/p>\n<p>Si necesita el informe de ensayo de una clase de filtro, unas dimensiones o un caudal concretos, escr\u00edbanos a <a href=\"mailto:info@ulpatek.com\">info@ulpatek.com<\/a>.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Respuesta breve La ISO 16890 es la norma internacional vigente para los filtros de aire utilizados en ventilaci\u00f3n general. Sustituy\u00f3 a la EN 779:2012, anulada en toda Europa el 30&hellip; <a class=\"read-more-link\" href=\"https:\/\/www.ulpatek.com\/es\/tecnologia-de-filtracion\/comparacion-de-normas-de-filtros-iso-16890-en-779-merv\/\">Read more<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":11078,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_exactmetrics_skip_tracking":false,"footnotes":""},"class_list":["post-14349","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/es\/wp-json\/wp\/v2\/pages\/14349","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ulpatek.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/es\/wp-json\/wp\/v2\/comments?post=14349"}],"version-history":[{"count":0,"href":"https:\/\/www.ulpatek.com\/es\/wp-json\/wp\/v2\/pages\/14349\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/es\/wp-json\/wp\/v2\/pages\/11078"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/es\/wp-json\/wp\/v2\/media?parent=14349"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}