{"id":14291,"date":"2026-09-23T12:47:49","date_gmt":"2026-09-23T09:47:49","guid":{"rendered":"https:\/\/www.ulpatek.com\/filtertechnik\/filternormen-im-vergleich-iso-16890-en-779-merv\/"},"modified":"2026-09-29T15:58:17","modified_gmt":"2026-09-29T12:58:17","slug":"filternormen-im-vergleich-iso-16890-en-779-merv","status":"publish","type":"page","link":"https:\/\/www.ulpatek.com\/de\/filtertechnik\/filternormen-im-vergleich-iso-16890-en-779-merv\/","title":{"rendered":"Filternormen im Vergleich: ISO 16890, EN 779 und MERV"},"content":{"rendered":"<style>\n.ulp-doc{font-size:16px;line-height:1.65}\n.ulp-doc h2{margin:38px 0 14px;font-size:26px;line-height:1.3}\n.ulp-doc h3{margin:26px 0 10px;font-size:19px;line-height:1.35}\n.ulp-doc p{margin:0 0 16px}\n.ulp-doc ul{margin:0 0 20px 20px}\n.ulp-doc li{margin:0 0 8px}\n.ulp-doc .tbl{overflow-x:auto;margin:0 0 28px;-webkit-overflow-scrolling:touch}\n.ulp-doc table{width:100%;border-collapse:collapse;font-size:15px;min-width:520px}\n.ulp-doc th,.ulp-doc td{border:1px solid #d8dde0;padding:9px 11px;vertical-align:top;text-align:left}\n.ulp-doc th{background:#eef3f6;font-weight:600}\n.ulp-doc tbody tr:nth-child(even){background:#fafbfc}\n.ulp-doc .lead{font-size:17px;background:#f4f8fa;border-left:4px solid #1f4e79;padding:16px 18px;margin:0 0 24px}\n<\/style>\n<div class=\"ulp-doc\">\n<h2>Kurz gesagt<\/h2>\n<p class=\"lead\"><strong>Die ISO 16890 ist die aktuelle internationale Norm f\u00fcr Luftfilter der allgemeinen Raumlufttechnik. Sie hat die EN 779:2012 abgel\u00f6st, die europaweit am 30. Juni 2018 zur\u00fcckgezogen wurde. Eine exakte Eins-zu-eins-Umrechnung zwischen beiden Normen gibt es nicht: Ein F7-Filter \u201eentspricht\u201c keiner bestimmten ISO-16890-Klasse, sondern nur einem Bereich m\u00f6glicher Klassen.<\/strong> Die ISO 16890 klassifiziert einen Filter danach, welchen Anteil des luftgetragenen Feinstaubs er abscheidet &ndash; ePM<sub>1<\/sub>, ePM<sub>2,5<\/sub>, ePM<sub>10<\/sub> oder ISO Coarse &ndash;, statt nach dem Abscheidegrad bei einer einzigen Partikelgr\u00f6\u00dfe von 0,4\u00a0&micro;m. MERV (ANSI\/ASHRAE 52.2) bleibt ein eigenst\u00e4ndiges nordamerikanisches System, das ebenfalls mit keiner der beiden Normen exakt \u00fcbereinstimmt.<\/p>\n<h3>Das Wichtigste auf einen Blick<\/h3>\n<ul>\n<li><strong>Aktuelle Norm:<\/strong> EN ISO 16890 in vier Teilen &ndash; Teil 1 (Klassifizierung) ISO 16890-1:2016, Teil 2 (Fraktionsabscheidegrad und Durchflusswiderstand) ISO 16890-2:2022, Teil 3 (gravimetrischer Abscheidegrad und Staubspeicherf\u00e4higkeit) ISO 16890-3:2024, Teil 4 (Konditionierung mit Isopropanol, IPA) ISO 16890-4:2022.<\/li>\n<li><strong>Zur\u00fcckgezogene Norm:<\/strong> EN 779:2012 &ndash; Klassen G1&ndash;G4, M5&ndash;M6, F7&ndash;F9. F\u00fcr die Klassifizierung neuer Produkte in den CEN-Mitgliedsl\u00e4ndern nicht mehr g\u00fcltig.<\/li>\n<li><strong>Oberhalb der ISO 16890:<\/strong> EPA-, HEPA- und ULPA-Filter fallen nicht unter die ISO 16890. Sie werden nach EN 1822 (E10&ndash;U17) und ISO 29463 (ISO 15 E &ndash; ISO 75 U) klassifiziert.<\/li>\n<li><strong>Nordamerika:<\/strong> MERV 1&ndash;16 nach ANSI\/ASHRAE 52.2. MERV 17&ndash;20 tauchen in manchen Ver\u00f6ffentlichungen auf, liegen aber au\u00dferhalb des Anwendungsbereichs des Pr\u00fcfverfahrens nach 52.2.<\/li>\n<li><strong>Umrechnung:<\/strong> Es gibt nur Richtbereiche. Fordern Sie stets den ISO-16890-Pr\u00fcfbericht des konkreten Filters an.<\/li>\n<\/ul>\n<h2>Warum die EN 779 abgel\u00f6st wurde<\/h2>\n<p>Die EN 779:2012 bewertete einen Filter nach seinem mittleren Abscheidegrad f\u00fcr Partikel einer einzigen Gr\u00f6\u00dfe &ndash; 0,4\u00a0&micro;m &ndash;, gemessen w\u00e4hrend der Beladung mit synthetischem Staub. \u00dcber die Wirkung des Filters auf den Staub, den Menschen tats\u00e4chlich einatmen, sagte dieser Wert sehr wenig aus.<\/p>\n<p>Die ISO 16890 misst den Fraktionsabscheidegrad \u00fcber den gesamten Bereich von 0,3&ndash;10\u00a0&micro;m und gewichtet die Messwerte anschlie\u00dfend mit den realen Partikelgr\u00f6\u00dfenverteilungen st\u00e4dtischer und l\u00e4ndlicher Au\u00dfenluft. Das Ergebnis ist der Anteil an PM<sub>1<\/sub>, PM<sub>2,5<\/sub> oder PM<sub>10<\/sub>, den der Filter abscheidet &ndash; also dieselben Feinstaubfraktionen, mit denen auch die Weltgesundheitsorganisation und die Gesetzgebung zur Luftqualit\u00e4t arbeiten. Planer k\u00f6nnen eine Filterklasse damit direkt mit einem Ziel f\u00fcr die Raumluftqualit\u00e4t verkn\u00fcpfen.<\/p>\n<h3>Die wichtigsten Unterschiede<\/h3>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>&nbsp;<\/th>\n<th>EN 779:2012 (zur\u00fcckgezogen)<\/th>\n<th>EN ISO 16890<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Bewertete Partikelgr\u00f6\u00dfe<\/td>\n<td>Nur 0,4\u00a0&micro;m<\/td>\n<td>0,3\u00a0&micro;m &ndash; 10\u00a0&micro;m<\/td>\n<\/tr>\n<tr>\n<td>Klassen<\/td>\n<td>G1&ndash;G4, M5&ndash;M6, F7&ndash;F9<\/td>\n<td>ISO Coarse, ISO ePM<sub>10<\/sub>, ISO ePM<sub>2,5<\/sub>, ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>Elektrostatische Ladung<\/td>\n<td>Probe des Filtermediums entladen (Mindestabscheidegrad)<\/td>\n<td>Gesamtes Filterelement in Isopropanoldampf konditioniert<\/td>\n<\/tr>\n<tr>\n<td>Pr\u00fcfstaub zur Beladung<\/td>\n<td>Synthetischer ASHRAE-Pr\u00fcfstaub<\/td>\n<td>Pr\u00fcfstaub ISO A2 Fine<\/td>\n<\/tr>\n<tr>\n<td>Druckdifferenz am Pr\u00fcfende<\/td>\n<td>G-Klassen: 250\u00a0Pa; M- und F-Klassen: 450\u00a0Pa<\/td>\n<td>ISO Coarse \/ ePM<sub>10<\/sub> &lt; 50\u00a0%: 200\u00a0Pa; ePM<sub>x<\/sub> &ge; 50\u00a0%: 300\u00a0Pa<\/td>\n<\/tr>\n<tr>\n<td>Geografischer Geltungsbereich<\/td>\n<td>Europa (CEN)<\/td>\n<td>International (ISO)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Wie eine ISO-16890-Klasse vergeben wird<\/h2>\n<p>Ein Filter wird der h\u00f6chsten Gruppe zugeordnet, deren Anforderung er erf\u00fcllt; der angegebene Abscheidegrad wird auf das n\u00e4chstniedrigere Vielfache von 5\u00a0% <em>abgerundet<\/em>.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Gruppe<\/th>\n<th>Anforderung<\/th>\n<th>Angabe als<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<td>ePM<sub>1<\/sub> im Anfangszustand &ge; 50\u00a0% <em>und<\/em> ePM<sub>1,min<\/sub> im entladenen Zustand &ge; 50\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<td>ePM<sub>2,5<\/sub> im Anfangszustand &ge; 50\u00a0% <em>und<\/em> ePM<sub>2,5,min<\/sub> im entladenen Zustand &ge; 50\u00a0%<\/td>\n<td>ISO ePM<sub>2,5<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<td>ePM<sub>10<\/sub> im Anfangszustand &ge; 50\u00a0% (keine Anforderung an den entladenen Zustand)<\/td>\n<td>ISO ePM<sub>10<\/sub> 50% &hellip; 95%<\/td>\n<\/tr>\n<tr>\n<td>ISO Coarse<\/td>\n<td>ePM<sub>10<\/sub> &lt; 50\u00a0%<\/td>\n<td>ISO Coarse 5% &hellip; 95% (gravimetrischer Abscheidegrad)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>Beispiel.<\/strong> Ein V-Compact-Filter, der nach EN 779 als F8 klassifiziert war, wird nach ISO 16890 gepr\u00fcft und erreicht 73\u00a0% ePM<sub>1<\/sub>, 80\u00a0% ePM<sub>2,5<\/sub> und 93\u00a0% ePM<sub>10<\/sub>. Da er die Anforderung f\u00fcr ePM<sub>1<\/sub> erf\u00fcllt, wird er in die h\u00f6chste Gruppe eingestuft, f\u00fcr die er sich qualifiziert, und der Wert wird in Schritten von 5\u00a0% abgerundet: <strong>ISO ePM<sub>1<\/sub> 70%<\/strong>.<\/p>\n<p>Das \u201ee\u201c steht f\u00fcr \u201eefficiency\u201c (Abscheidegrad), der tiefgestellte Index f\u00fcr die Feinstaubfraktion. ISO ePM<sub>1<\/sub> 70% bedeutet, dass der Filter 70\u00a0% der PM<sub>1<\/sub>-Partikel abscheidet.<\/p>\n<h2>Von EN 779 zu ISO 16890: Richtbereiche, keine Entsprechungen<\/h2>\n<p>Eine einzelne EN-779-Klasse kann je nach verwendetem Filtermedium in unterschiedliche ISO-16890-Klassen fallen. Zwei Filter, die beide als F7 gekennzeichnet waren, k\u00f6nnen bei der Pr\u00fcfung als ISO ePM<sub>1<\/sub> 50% bzw. als ISO ePM<sub>2,5<\/sub> 65% eingestuft werden. Am st\u00e4rksten ausgepr\u00e4gt ist das bei synthetischen Elektretmedien, deren Abscheidegrad sinkt, sobald die elektrostatische Ladung neutralisiert ist &ndash; genau das macht der Konditionierungsschritt der ISO 16890 sichtbar.<\/p>\n<p>Die folgende Tabelle zeigt, in welchen Bereichen die gemessenen mittleren Abscheidegrade von Filtern der fr\u00fcheren EN-779-Klassen bei einer erneuten Pr\u00fcfung nach ISO 16890 typischerweise liegen. <strong>Nutzen Sie sie, um eine Vorauswahl einzugrenzen, niemals als Ersatz f\u00fcr den Pr\u00fcfbericht.<\/strong><\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Klasse nach EN 779:2012<\/th>\n<th>ePM<sub>1<\/sub><\/th>\n<th>ePM<sub>2,5<\/sub><\/th>\n<th>ePM<sub>10<\/sub><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>M5<\/td>\n<td>5\u00a0% &ndash; 35\u00a0%<\/td>\n<td>10\u00a0% &ndash; 40\u00a0%<\/td>\n<td>40\u00a0% &ndash; 70\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>M6<\/td>\n<td>10\u00a0% &ndash; 40\u00a0%<\/td>\n<td>20\u00a0% &ndash; 50\u00a0%<\/td>\n<td>60\u00a0% &ndash; 80\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>F7<\/td>\n<td>40\u00a0% &ndash; 65\u00a0%<\/td>\n<td>65\u00a0% &ndash; 75\u00a0%<\/td>\n<td>80\u00a0% &ndash; 90\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>F8<\/td>\n<td>65\u00a0% &ndash; 90\u00a0%<\/td>\n<td>75\u00a0% &ndash; 95\u00a0%<\/td>\n<td>90\u00a0% &ndash; 100\u00a0%<\/td>\n<\/tr>\n<tr>\n<td>F9<\/td>\n<td>80\u00a0% &ndash; 90\u00a0%<\/td>\n<td>85\u00a0% &ndash; 95\u00a0%<\/td>\n<td>90\u00a0% &ndash; 100\u00a0%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Filter der Klassen G1&ndash;G4 fallen in die Gruppe ISO Coarse. Ihr ISO-Coarse-Wert ist ein gravimetrischer Abscheidegrad und mit einem ePM<sub>x<\/sub>-Abscheidegrad nicht vergleichbar.<\/p>\n<h2>MERV (ANSI\/ASHRAE 52.2) im Vergleich<\/h2>\n<p>MERV wird aus dem zusammengesetzten mittleren Fraktionsabscheidegrad in drei Gr\u00f6\u00dfenbereichen abgeleitet: E1 = 0,30&ndash;1,0\u00a0&micro;m, E2 = 1,0&ndash;3,0\u00a0&micro;m, E3 = 3,0&ndash;10,0\u00a0&micro;m. Ein Filter erh\u00e4lt den h\u00f6chsten MERV-Wert, f\u00fcr den er <em>alle<\/em> Anforderungen erf\u00fcllt.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>MERV<\/th>\n<th>E1 (0,30&ndash;1,0\u00a0&micro;m)<\/th>\n<th>E2 (1,0&ndash;3,0\u00a0&micro;m)<\/th>\n<th>E3 (3,0&ndash;10,0\u00a0&micro;m)<\/th>\n<th>ISO-16890-Gruppe (Richtwert)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>1&ndash;4<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&lt; 20\u00a0%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 20\u00a0%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 35\u00a0%<\/td>\n<td>ISO Coarse<\/td>\n<\/tr>\n<tr>\n<td>7<\/td>\n<td>&ndash;<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 50\u00a0%<\/td>\n<td>ISO Coarse &ndash; ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 20\u00a0%<\/td>\n<td>&ge; 70\u00a0%<\/td>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>9<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 35\u00a0%<\/td>\n<td>&ge; 75\u00a0%<\/td>\n<td>ISO ePM<sub>10<\/sub><\/td>\n<\/tr>\n<tr>\n<td>10<\/td>\n<td>&ndash;<\/td>\n<td>&ge; 50\u00a0%<\/td>\n<td>&ge; 80\u00a0%<\/td>\n<td>ISO ePM<sub>10<\/sub> &ndash; ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>11<\/td>\n<td>&ge; 20\u00a0%<\/td>\n<td>&ge; 65\u00a0%<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>12<\/td>\n<td>&ge; 35\u00a0%<\/td>\n<td>&ge; 80\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>ISO ePM<sub>2,5<\/sub><\/td>\n<\/tr>\n<tr>\n<td>13<\/td>\n<td>&ge; 50\u00a0%<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>14<\/td>\n<td>&ge; 75\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>15<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>&ge; 90\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<tr>\n<td>16<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>ISO ePM<sub>1<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Die letzte Spalte dient nur der groben Orientierung. MERV arbeitet mit einem anderen Aerosol, anderen Gr\u00f6\u00dfenbereichen und ohne Konditionierung mit Isopropanol; ein Filter mit MERV 13 und ein Filter der Klasse ISO ePM<sub>1<\/sub> 50% sind daher schon von der Definition her nicht austauschbar.<\/p>\n<h2>Wo die ISO 16890 endet: EPA, HEPA und ULPA<\/h2>\n<p>Die ISO 16890 erfasst Filter bis etwa ISO ePM<sub>1<\/sub> 95%. Dar\u00fcber werden Filter nach EN 1822 oder ISO 29463 mit Partikelz\u00e4hlung bei der Partikelgr\u00f6\u00dfe mit dem geringsten Abscheidegrad (MPPS) gepr\u00fcft, und jedes Filterelement wird einzeln einer Leckpr\u00fcfung unterzogen.<\/p>\n<div class=\"tbl\">\n<table>\n<thead>\n<tr>\n<th>Klasse nach EN 1822<\/th>\n<th>Abscheidegrad bei MPPS (Integralwert)<\/th>\n<th>Abscheidegrad (Lokalwert)<\/th>\n<th>Klasse nach ISO 29463<\/th>\n<th>Gruppe<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>E10<\/td>\n<td>&ge; 85\u00a0%<\/td>\n<td>&ndash;<\/td>\n<td>Keine Entsprechung<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>E11<\/td>\n<td>&ge; 95\u00a0%<\/td>\n<td>&ndash;<\/td>\n<td>ISO 15 E<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>E12<\/td>\n<td>&ge; 99,5\u00a0%<\/td>\n<td>&ndash;<\/td>\n<td>ISO 25 E<\/td>\n<td>EPA<\/td>\n<\/tr>\n<tr>\n<td>H13<\/td>\n<td>&ge; 99,95\u00a0%<\/td>\n<td>&ge; 99,75\u00a0%<\/td>\n<td>ISO 35 H<\/td>\n<td>HEPA<\/td>\n<\/tr>\n<tr>\n<td>H14<\/td>\n<td>&ge; 99,995\u00a0%<\/td>\n<td>&ge; 99,975\u00a0%<\/td>\n<td>ISO 45 H<\/td>\n<td>HEPA<\/td>\n<\/tr>\n<tr>\n<td>U15<\/td>\n<td>&ge; 99,9995\u00a0%<\/td>\n<td>&ge; 99,9975\u00a0%<\/td>\n<td>ISO 55 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<tr>\n<td>U16<\/td>\n<td>&ge; 99,99995\u00a0%<\/td>\n<td>&ge; 99,99975\u00a0%<\/td>\n<td>ISO 65 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<tr>\n<td>U17<\/td>\n<td>&ge; 99,999995\u00a0%<\/td>\n<td>&ge; 99,9999\u00a0%<\/td>\n<td>ISO 75 U<\/td>\n<td>ULPA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Die ISO 29463 beginnt bei ISO 15 E; f\u00fcr die Klasse E10 nach EN 1822 gibt es daher kein Gegenst\u00fcck nach ISO 29463. Die n\u00e4chstliegende Entsprechung nach ISO 16890 ist ISO ePM<sub>1<\/sub> &gt; 95%.<\/p>\n<h2>Die Filterklasse f\u00fcr ein Projekt w\u00e4hlen<\/h2>\n<p>Gehen Sie von der Au\u00dfenluftqualit\u00e4t am Standort und von der geforderten Raumluftqualit\u00e4t aus, nicht von der Kennzeichnung des bisherigen Filters.<\/p>\n<ul>\n<li><strong>Vorfiltration und Anlagenschutz:<\/strong> ISO Coarse oder ISO ePM<sub>10<\/sub>. Sch\u00fctzt Register, Ventilatoren und nachgeschaltete Filter vor Flusen, Insekten und Sand.<\/li>\n<li><strong>Allgemeine L\u00fcftung in Gewerbegeb\u00e4uden:<\/strong> ISO ePM<sub>1<\/sub> 50&ndash;60% ist der \u00fcbliche Ersatz f\u00fcr das, was fr\u00fcher als F7 ausgeschrieben wurde.<\/li>\n<li><strong>B\u00fcros und Schulen mit belasteter Stadtluft:<\/strong> ISO ePM<sub>1<\/sub> 70&ndash;80%.<\/li>\n<li><strong>Krankenh\u00e4user, Pharma- und Lebensmittelproduktion:<\/strong> ISO ePM<sub>1<\/sub> 80% oder h\u00f6her, als letzte Stufe vor einem HEPA-Filter.<\/li>\n<li><strong>Reinr\u00e4ume und Containment:<\/strong> H13, H14 oder h\u00f6her nach EN 1822 \/ ISO 29463, festgelegt zusammen mit der Reinraumklasse nach ISO 14644-1.<\/li>\n<\/ul>\n<p>Die Eurovent-Empfehlung REC 4\/23 gibt Hinweise zur Wahl der Filterklasse, ausgehend von der Au\u00dfenluftqualit\u00e4t am Standort der Anlage und von der angestrebten Raumluftqualit\u00e4t. An ihr orientieren sich heute die meisten europ\u00e4ischen Ausschreibungen.<\/p>\n<h2>H\u00e4ufige Fragen<\/h2>\n<h3>Gilt die EN 779 noch?<\/h3>\n<p>Nein. Die EN 779:2012 wurde am 30. Juni 2018 zur\u00fcckgezogen und durch die EN ISO 16890 ersetzt. Auf dem Markt k\u00f6nnen Filter zwar noch informell als \u201eF7\u201c oder \u201eM5\u201c bezeichnet werden, ein neuer Filter sollte jedoch nach ISO 16890 ausgeschrieben, gepr\u00fcft und dokumentiert werden.<\/p>\n<h3>Welche ISO-16890-Klasse entspricht einem F7-Filter?<\/h3>\n<p>Eine einzelne Entsprechung gibt es nicht. Filter, die als F7 klassifiziert waren, erreichen in der Pr\u00fcfung typischerweise ePM<sub>1<\/sub> 40&ndash;65\u00a0%, ePM<sub>2,5<\/sub> 65&ndash;75\u00a0% und ePM<sub>10<\/sub> 80&ndash;90\u00a0%. In der Praxis ist ISO ePM<sub>1<\/sub> 50&ndash;60% der h\u00e4ufigste Ersatz; die richtige Antwort f\u00fcr einen bestimmten Filter kann jedoch nur dessen Pr\u00fcfbericht liefern.<\/p>\n<h3>Was bedeutet ISO ePM1 70%?<\/h3>\n<p>Der Filter scheidet 70\u00a0% des Feinstaubs mit einem aerodynamischen Durchmesser bis 1\u00a0&micro;m ab, gemessen \u00fcber den Bereich 0,3&ndash;10\u00a0&micro;m und gewichtet mit einer genormten Partikelgr\u00f6\u00dfenverteilung st\u00e4dtischer Luft. Die angegebenen Werte werden in Schritten von 5\u00a0% abgerundet.<\/p>\n<h3>Warum wird der Filter nach ISO 16890 mit Isopropanol entladen?<\/h3>\n<p>Viele synthetische Filtermedien scheiden Partikel mithilfe einer elektrostatischen Ladung ab. Diese Ladung baut sich im Betrieb ab, sodass der Anfangsabscheidegrad die tats\u00e4chliche Leistung zu hoch ausweist. Nach ISO 16890-4 wird das vollst\u00e4ndige Filterelement in ges\u00e4ttigtem Isopropanoldampf konditioniert und anschlie\u00dfend erneut gepr\u00fcft. So gibt die Klasse einen Abscheidegrad wieder, der nicht von der Ladung abh\u00e4ngt.<\/p>\n<h3>Ist MERV 13 dasselbe wie ISO ePM1 50%?<\/h3>\n<p>In der Anwendung sind beide grob vergleichbar, per Definition aber nicht gleichwertig. Die beiden Normen arbeiten mit unterschiedlichen Pr\u00fcfaerosolen, unterschiedlichen Partikelgr\u00f6\u00dfenbereichen und unterschiedlicher Konditionierung. Ein Filter sollte die Klassifizierung nach der Norm tragen, die in der Ausschreibung genannt ist, und keinen umgerechneten Wert.<\/p>\n<h3>Erfasst die ISO 16890 auch HEPA-Filter?<\/h3>\n<p>Nein. Die ISO 16890 endet bei etwa ISO ePM<sub>1<\/sub> 95%. EPA-, HEPA- und ULPA-Filter werden nach EN 1822 oder ISO 29463 klassifiziert; diese Normen pr\u00fcfen bei der Partikelgr\u00f6\u00dfe mit dem geringsten Abscheidegrad und verlangen f\u00fcr jedes Filterelement eine eigene Leckpr\u00fcfung.<\/p>\n<h3>Welche Teile der ISO 16890 gelten derzeit?<\/h3>\n<p>ISO 16890-1:2016 f\u00fcr das Klassifizierungssystem, ISO 16890-2:2022 f\u00fcr Fraktionsabscheidegrad und Durchflusswiderstand, ISO 16890-3:2024 f\u00fcr gravimetrischen Abscheidegrad und Staubspeicherf\u00e4higkeit sowie ISO 16890-4:2022 f\u00fcr das Konditionierungsverfahren mit Isopropanol.<\/p>\n<h3>Wie pr\u00fcfe ich die ISO-16890-Angabe eines Lieferanten?<\/h3>\n<p>Fordern Sie den Pr\u00fcfbericht genau dieses Filtermodells in genau dieser Baugr\u00f6\u00dfe an. Er sollte die Abscheidegrade ePM<sub>x<\/sub> im Anfangszustand und im entladenen Zustand, die Anfangsdruckdifferenz beim Nennvolumenstrom, die Druckdifferenz am Pr\u00fcfende und das pr\u00fcfende Labor angeben.<\/p>\n<h2>Pr\u00fcfung bei Ulpatek<\/h2>\n<p>Ulpatek pr\u00fcft seine Filter im eigenen Filterpr\u00fcflabor ULPALAB. Es ist mit einem Pr\u00fcfsystem nach ISO 16890, einem Pr\u00fcfsystem f\u00fcr die Leckpr\u00fcfung von HEPA- und ULPA-Filtern im Scan-Verfahren nach EN 1822 \/ ISO 29463, einem Leistungspr\u00fcfsystem und einem Filtermedien-Pr\u00fcfsystem ausgestattet. Ulpatek ist Eurovent-zertifiziert und fertigt nach ISO 16890 und ISO 29463 (EN 1822).<\/p>\n<p>Wenn Sie den Pr\u00fcfbericht f\u00fcr eine bestimmte Filterklasse, Abmessung oder einen bestimmten Volumenstrom ben\u00f6tigen, schreiben Sie uns an <a href=\"mailto:info@ulpatek.com\">info@ulpatek.com<\/a>.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Kurz gesagt Die ISO 16890 ist die aktuelle internationale Norm f\u00fcr Luftfilter der allgemeinen Raumlufttechnik. Sie hat die EN 779:2012 abgel\u00f6st, die europaweit am 30. Juni 2018 zur\u00fcckgezogen wurde. Eine&hellip; <a class=\"read-more-link\" href=\"https:\/\/www.ulpatek.com\/de\/filtertechnik\/filternormen-im-vergleich-iso-16890-en-779-merv\/\">Read more<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":11041,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_exactmetrics_skip_tracking":false,"footnotes":""},"class_list":["post-14291","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.ulpatek.com\/de\/wp-json\/wp\/v2\/pages\/14291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ulpatek.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ulpatek.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/de\/wp-json\/wp\/v2\/comments?post=14291"}],"version-history":[{"count":0,"href":"https:\/\/www.ulpatek.com\/de\/wp-json\/wp\/v2\/pages\/14291\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.ulpatek.com\/de\/wp-json\/wp\/v2\/pages\/11041"}],"wp:attachment":[{"href":"https:\/\/www.ulpatek.com\/de\/wp-json\/wp\/v2\/media?parent=14291"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}